Desenvolvimento de uma fase extratora com polímeros de impressão molecular para extração em fase sólida de Venlafaxina, O-desmetilvenlafaxina e N-desmetilvenlafaxina em amostras de plasmas e análises por cromatografia líquida de ultra eficiência acoplada à espectometria de massas em tandem (UPLC-MS/MS). / Development of an extraction phase with molecularly imprinted polymers for solid phase extraction of venlafaxine, o-desmethylvenlafaxine, and n-desmethylvenlafaxine in plasma samples and analysis by Ultra Performance Liquid Chromatography-tandem mass spectrometry (UPLC-MS/MS)

A venlafaxina (VEN), em razão de sua eficácia e brandos efeitos adversos, tem sido um dos antidepressivos mais prescritos no tratamento da depressão e ansiedade. Neste trabalho, um método analítico empregando as técnicas MISPE miniaturizada e cromatografia líquida acoplada à espectrometria de massas em Tandem, foi utilizado para a determinação de VEN e seus principais metabólitos em amostras de plasma para fins de monitorização terapêutica. A fase MIP foi sintetizada via polimerização radicalar por precipitação, fazendo uso de VEN (molécula molde), ácido metacrílico (monômero funcional), etileno glicol dimetacrilato, (reagente reticulante) e 2,2 azobisisobutironitrila (iniciador radicalar) em tolueno (solvente). Para controle utilizou-se o polímero não impresso (NIP), sintetizado por procedimento análogo ao do MIP, porém sem o uso da molécula molde. A caracterização química e estrutural dos polímeros foi realizada por espectroscopia no infravermelho com transformada de fourier e microscopia eletrônica de varredura. A otimização das variáveis de MISPE miniaturizada favoreceu a detectabilidade analítica e diminuiu o efeito de memória. As extrações realizadas com MIP apresentaram taxa de recuperação de 84% para VEN e de 2-28% para os antidepressivos (clorpromazina, fluoxetina, clomipramina, imipramina e sertralina). O polímero não impresso apresentou baixa recuperação para a VEN (taxa de recuperação: 49%) e para os demais antidepressivos (taxas de recuperação menores que 40%). Estes experimentos comprovam a seletividade da fase MIP desenvolvida. O método padronizado apresentou linearidade na faixa de 3 a 700 ng mL-1 para VEN, 5 a 700 ng mL-1 para O-desmetilvenlafaxina (ODV) e de 3 a 500 ng mL-1 para N-desmetilvenlafaxina (NDV), precisão com coeficientes de variação menores que 15% e exatidão com valores de erro padrão relativo na faixa de -11,8 a 16,01 %. As concentrações correspondentes aos limites inferiores de quantificação para VEN (3 ng mL-1) e ODV ( 5 ng mL-1) foram inferiores aos intervalos terapêuticos preconizados. O método desenvolvido, quando comparado a aos métodos da literatura para determinação de VEN e metabolitos, apresentou maior seletividade, menor consumo de amostra e de solventes orgânicos e permitiu a reutilização da fase extratora. Segundo os parâmetros de validação analítica avaliados e amostras de pacientes em terapia com VEN analisadas, o método proposto é adequado para determinação de VEN, ODV e NDV em amostras de plasma para fins de monitorização terapêutica. / Venlafaxine elicits a small number of adverse effects, so it is one of the most frequently prescribed drugs to treat major depression, generalized anxiety, and social anxiety disorders in adults. In this study, venlafaxine (VEN), O-desmethylvenlafaxine (ODV), and N-desmethylvenlafaxine (NDV) were pre-concentrated with the aid of miniaturized SPE based on MIPs as extraction phase. MIPs are synthetic polymers with cavities specifically designed to hold a target molecule or structurally similar compounds. The molecularly imprinted polymers were prepared by addition of VEN, metacrylic acid (MAA, monomer), ethylene glycol dimethacrylate (EGDMA, cross-linker), and 2,2-azobisisobutyronitrile (AIBN, initiator) to toluene (solvent). The non-imprinted polymer (NIP), used for comparison, was also synthesized by following exactly the same procedure, but excluding the template VEN from the formulation. The polymer was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy (SEM). Optimization of the MIP phase extraction variables favored miniaturized analytical detectability and reduced the memory effect. The extractions performed with the synthesized MIP showed recovery rate of 84% for VEN and 2-28% for other antidepressants (chlorpromazine, fluoxetine, clomipramine, imipramine, and sertraline). The non-imprinted polymer provided low recovery of VEN (recovery rate: 49%) and other antidepressants (recovery rates lower than 40%). These experiments demonstrated the selectivity of the developed MIP phase. The standardized method was linear in the range of 300 - 700 ng mL-1 for VEN, 5-700 ng mL-1 for ODV, and 3 to 500 ng mL-1 for NDV. Precision had coefficients of variation smaller than 15%; the accuracy standard error values ranged from -11.8 to 16.01%. Compared with literature methods, the developed method was more selective for determination of VEN and metabolites, required lower consumption of sample and organic solvents, and enabled reuse of the extraction phase. According to the assessed analytical validation parameters and to the analysis of samples obtained from patients undergoing therapy with VEN, the proposed method is suitable to determine VEN, NDV, and ODV in plasma samples for therapeutic drug monitoring.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-15052015-122818
Date18 March 2015
CreatorsLuís Felippe Cabral Miranda
ContributorsMaria Eugenia Queiroz Nassur, Fernando Mauro Lanças, Anderson Rodrigo Moraes de Oliveira
PublisherUniversidade de São Paulo, Química, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.002 seconds