Return to search

Avaliação do método de extração eletroquímica de cloretos para reabilitação de estruturas de concreto com problemas de corrosão de armaduras. / Evaluation of the method of electrochemical extraction of chlorides ions for the rehabilitation of concrete structures with reinforcement corrosion problems.

O presente trabalho avalia o método de extração eletroquímica de íons cloreto na reabilitação de estruturas de concreto com problemas de corrosão de armaduras. Essa metodologia pode ser utilizada para evitar as desvantagens da recuperação tradicional do reparo localizado. No procedimento experimental foram realizados ensaios de laboratório em corpos-de-prova de forma prismática com dimensões reduzidas, moldados com diferentes relações água/cimento. A penetração de cloretos nos corpos-de-prova foi realizada de maneiras distintas: câmara de névoa salina e semiciclos de secagem e imersão parcial. Entre outros aspectos, foi avaliada a influência da espessura de cobrimento e da relação água/cimento na resposta do método através da determinação do teor inicial e final dos íons cloreto.Nas conclusões observa-se que a eficiência desse método foi até superior à encontrada em outros trabalhos da literatura. Nas séries cuja penetração de cloretos se deu através da câmara de névoa salina em média foram removidos 78% dos íons cloreto inicialmente presentes no concreto, nas séries onde a penetração de cloretos foi por semiciclos de secagem e imersão parcial obteve-se 91% de eficiência de remoção. / This present project evaluates the method of electrochemical extraction of chloride ions for the rehabilitation of concrete structures with reinforcement corrosion problems. This methodology can be used to prevent the disadvantages of traditional repair strategies in the patch repair. In the experimental procedure, tests performed in laboratory with specimens of prismatic form with reduced dimensions had been carried through, molded with different water/cement ratio. The chloride penetration in the specimens was carried through in distinct ways: salt spray chamber and semi cycles of drying and partial immersion. Among others aspects, the influence of the concrete cover and the water/cement ratio has been evaluated in the efficiency of method by determining the initial and the final chloride content. In the conclusions it is noticed that not only the test results did verify that this method successfully extracted chloride ions but it was much more efficient than previously reported in the literature. In the series where chloride penetration comes through the salt spray chamber, on average, this method removed 78% of the content of initial chloride ions in the concrete, in the series where the chloride penetration was done by semi cycles of drying and partial immersion, 91% of removal efficiency was obtained.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-19042007-160242
Date11 October 2002
CreatorsEliana Cristina Barreto Monteiro
ContributorsPaulo Roberto do Lago Helene, Pedro Castro Borges, Isolda Costa, Enio José Pazini Figueiredo, Antonio Alberto Nepomuceno
PublisherUniversidade de São Paulo, Engenharia Civil, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds