Análise quantitativa de modelos de prototipagem rápida baseados em dados de tomografia volumétrica, por meio de inspeção de engenharia reversa tridimensional / Quantitative analysis of rapid prototyping models based on datas of cone beam computerized tomography by inspection of three-dimensional reverse engineering

O objetivo neste estudo foi avaliar a reprodutibilidade quantitativa dos modelos tridimensionais gerados por meio de imagens de tomografia volumétrica de feixe cônico, obtidos por dois tomógrafos volumétricos NEWTOM 9000 DVT (i- (Quantitative Radiology, Verona, Itália) e i-CAT (Imaging Sciencies Int. Hatfield, Pensilvânia. Estados Unidos da América), submetidos à inspeção de engenharia reversa. Uma mandíbula macerada foi digitalizada por meio do SCANNER 3D VIVID 910, com precisão de 0,01 mm, associado à fotometria digital, sendo utilizado o software GEOMAGIC STUDIO, e assim obteve-se um modelo considerado padrão ouro. Posteriormente realizamos o exame de tomografia volumétrica de feixe cônico, na mesma mandíbula nos dois tomógrafos volumétricos, obtendo-se assim os modelos virtuais tridimensionais. Por meio de um alinhamento das geometrias do padrão ouro com os modelos virtuais resultantes da tomografia do aparelho NEWTOM 9000 DVT e do i-CAT, foram observadas as possíveis discrepâncias. Concluímos que estas alterações encontradas após a análise quantitativa das diversas regiões foram menores nas imagens adquiridas pelo tomógrafo volumétrico de feixe cônico modelo i-CAT, e portanto possibilitam a geração de modelos de prototipagem rápida de melhor qualidade. / The purpose of this study was to evaluate the quantitative reproductability of the 3d models created using CT images. The images used were obtained from two different cone beam tomographs: NEWTOM 9000 DVT (Quantitative Radiology, Verona, Italy) and i-CAT ( Imaging Sciences Int., Hatfield, EUA) and then inspected through reverse engineering processing software. A dry mandible was digitalized using a 3D Scanner VIVID 910 and the GEOMAGIC STUDIO software to obtain a 0,01mm precision model considered to be our gold standard. Two distinct 3D virtual models were then created after submitting the same dry mandible to a cone beam exam on both tomographs (NEWTOM and i-Cat). Possible discrepancies between the 3D models and the gold standard were analyzed through and alignment of their geometries. After evaluating the discrepancies at the different sites of the models, we concluded that the virtual model obtained using the i-Cat tomograph images was more accurate and therefore of greater quality.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-27102009-095334
Date18 September 2009
CreatorsFatima Maria de Angelis Kang
ContributorsIsrael Chilvarquer, Claudio Froes de Freitas, Jorge Elie Hayek
PublisherUniversidade de São Paulo, Odontologia (Diagnóstico Bucal), USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0152 seconds