Return to search

Implementação de método rápido e de baixo custo no LACEN/RJ para avaliação de organoclorados em água de soluções alternativas de abastecimento / Development of a fast and low cost method at LACEN/RJ for assessment of organochlorines in drinking water from wells

Made available in DSpace on 2012-05-07T15:02:17Z (GMT). No. of bitstreams: 2
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
000006.pdf: 1337746 bytes, checksum: c97b92460d1afa99fa7e64e58c7a94a9 (MD5)
Previous issue date: 2009 / Made available in DSpace on 2016-07-29T14:54:55Z (GMT). No. of bitstreams: 4
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
000006.pdf: 1337746 bytes, checksum: c97b92460d1afa99fa7e64e58c7a94a9 (MD5)
000006.pdf.txt: 149863 bytes, checksum: f0ad50422f0378083c2fd5988d88b242 (MD5)
000006.pdf.jpg: 1120 bytes, checksum: 262dc8443fb7c361a07a1b5852f65188 (MD5)
Previous issue date: 2009 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / A disponibilidade de água potável e segura é um direito e uma condição indispensável para vida, garantidos pela Constituição Federal e pelo Sistema Único de Saúde (SUS). Em sua tabela 3, a Portaria 518/2004 - MS apresenta o padrão de potabilidade para substâncias químicas que representam risco à saúde e estabelece os valores máximos permitidos (VMP) em água para consumo humano para uma série de agrotóxicos, em sua maioria substâncias organocloradas. No entanto, somente a água distribuída pela rede geral de abastecimento tem a sua qualidade avaliada através do monitoramento realizado pelas companhias distribuidoras em seus laboratórios. O monitoramento da água das soluções alternativas apresenta uma dificuldade peculiar, pois muitas vezes não há um responsável ao qual possa ser formalmente imputado o controle da qualidade da água fornecida. No sentido de atender a necessidade de monitoramento da água das soluções alternativas, o objetivo principal deste trabalho foi a validação e a implementação de um método para análise de agrotóxicos organoclorados em água potável no Laboratório Central Noel Nutels/Rio de Janeiro visando o menor custo, menor tempo de execução, e menor geração de resíduos. O método escolhido foi a microextração líquido-líquido dispersiva (MELLD), onde uma mistura de solvente de extração, mais denso e imiscível no meio aquoso, com um solvente de dispersão miscível em ambos, é rapidamente injetada na amostra aquosa por meio de uma seringa. A análise instrumental foi efetuada por cromatografia à gás com detecção por captura de elétrons. O método foi validado para 12 agrotóxicos sendo: 4,4’-DDT, 2,4’-DDT, alfa-endossulfam, beta-endossulfam, alfa-HCH, beta-HCH, gama-HCH, delta-HCH, endrin, hexaclorobenzeno, metoxicloro e trifuralina. Os parâmetros de validação verificados encontraram-se todos dentro das faixas exigidas pelas normas em vigor. O teste com duas misturas de solvente de extração revelou que a mistura tetracloroetileno/acetona apresentou os melhores resultados em comparação com a de clorobenzeno/acetona. A análise de 10 amostras de água provenientes de soluções alternativas de abastecimento espalhadas pelo município de São José do Vale do Rio Preto/RJ mostrou que não há contaminação pelos agrotóxicos estudados, sendo todos os valores obtidos abaixo do limite de quantificação. / The availability of safe drinking water is a right and a prerequisite for life, guaranteed by the Constitution and the Unified Health System. In its table 3, the Ministry of Health ordinance n° 518/2004 presents the drinking water standards for chemicals that pose risk to health and sets the maximum contaminant level in water for human consumption to a number os pesticides, most of them organochlorinated substances. However, only the water distributed by the public supply network has its quality assessed by monitoring conducted in distributing companies’ laboratories. Monitoring the water from alternative sources presents a peculiar difficulty, because often there is no controller who could be formally responsible for the quality of the water being supplied. In order to meet the need for monitoring the water from alternative sources, the main objective of this study was to validate and to implement a method for analysis of organochlorine pesticides in drinking water at Noel Nutels Central Laboratory / Rio de Janeiro aiming the lower cost, lower execution time, and less waste generation. The chosen method was the dispersive liquid-liquid microextraction (DLLME), where a mixture of an extraction solvent, more dense and immiscible in water, with a dispersion solvent, miscible in both, is rapidly injected in the aqueous sample through a syringe. The instrumental analysis was performed by gas chromatography with electron-capture detection. The method was validated for 12 pesticides: 4,4’DDT, 2,4'DDT, alpha-endosulfan, beta-endosulfan, alpha-HCH, beta-HCH, gamma-HCH, delta-HCH, endrin, hexachlorobenzene, methoxychlor and trifluralin. The validation parameters were all in the range required by current protocols. The test between two mixtures of extraction solvents showed that the mixture tetrachlorethylene/acetone provided the best results in comparison with chlorobenzene/acetone. The analysis of 10 water samples from alternative supply sources throughout the municipality of São José do Vale do Rio Preto/RJ showed no contaminations by the pesticides studied, and all obtained values were below the quantification limits.

Identiferoai:union.ndltd.org:IBICT/oai:www.arca.fiocruz.br:icict/15148
Date January 2009
CreatorsNovotny, Thiago Santana
ContributorsKrauss, Thomas Manfred, Braga, Ana Maria Cheble Bahia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da FIOCRUZ, instname:Fundação Oswaldo Cruz, instacron:FIOCRUZ
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0057 seconds