Return to search

Efeito de diferentes metodologias de treinamento físico na função cardíaca e no controle barorreflexo cardíaco em modelo experimental de cardiopatia dilatada isquêmica

Submitted by Tatiana Silva (tsilva@icict.fiocruz.br) on 2012-12-26T17:37:12Z
No. of bitstreams: 1
gustavo_s_masson_ioc_bcm_0017_2010.pdf: 411061 bytes, checksum: c24ac1e7c8586dc59e7e02ab251a8183 (MD5) / Made available in DSpace on 2012-12-26T17:37:12Z (GMT). No. of bitstreams: 1
gustavo_s_masson_ioc_bcm_0017_2010.pdf: 411061 bytes, checksum: c24ac1e7c8586dc59e7e02ab251a8183 (MD5)
Previous issue date: 2010 / Fundação Oswaldo Cruz.Instituto Oswaldo Cruz. Rio de janeiro, RJ, Brasil / Introdução: O treinamento físico contínuo (Cont) é tradicionalmente empregado como
estratégia terapêutica não-farmacológica daIC. Contudo outros métodos de treinamento
vêem sendo crescentemente utilizadas. Objetivo:Avaliar o efeito de diferentes
metodologias de treinamento físico sobre a função cardíaca e sensibilidade barorreflexa
em modelo experimental de IC. Metodologia:Dividimos 43 ratos Wistar Kyoto,
machos e com massa corporal entre 250 e 350g em: IC e sham. O grupo IC foi
subdividido em: Cont (IC Cont), Intervalado moderado (IC IAer), Intervalado intenso
(IC IAna) e Sedentário (IC Sed). A IC foi induzida através da ligadura da artéria
coronária interventricular. Após 6 semanas do procedimento e ao final do treinamento,
foi avaliada a função cardíaca através do ecocardiograma. A medida da fração de ejeção
e dos diâmetros ventriculares e atriais foi efetuada pelo método de Simpson e módulo
M, respectivamente. No início, na quarta semana e ao final do treinamento, os ratos
foram submetidos ao teste de esforço máximo(TE) em esteira rolante. Após 48 horas do
terceiro TE, as variáveis hemodinâmicas (pressão arterial, frequência cardíaca e duplo
produto) e o controle barorreflexo cardíaco foram determinados. O índice de
sensibilidade barorreflexa foi obtido pela razão da variação da FC e da PA sistólica
antes e após cada infusão. O treinamento físico foi caracterizado por um período de 8
semanas, com uma freqüência semanal de 3 sessões, onde cada treino durou 30 minutos.
O IC Cont consistiu na manutenção de 70% da velocidade máxima obtida no TE, já o
IC IAna foi marcado pela alternância de segmentos de 1 min a 90% e 50% da
velocidade máxima no TE. Por outro lado, o IC IAer se caracterizou pela alternância de
períodos de 5 min a 80% e 60% da velocidade máxima no TE. Resultados:
Constatamos aumento significativo da fração de ejeção no ICCont (28,48±5% vs
39,2±11%) e IC IAer (31,03±7% vs42±9%). Sobre os diâmetros ventriculares e atriais
não observamos modificação significativa nos grupos treinados. Entretanto, o IC Sed
demonstrou aumento do diâmetro do ventrículo esquerdo em diástole (0,89±0,1cm vs
1±0,1cm). A respeito do índice de controlebarorreflexo cardíaco, apenas o IC Cont
apresentou um maior índice do que o IC Sed (1,65±1 bpm/mmHg vs 0,82±0,4
bpm/mmHg). Conclusão:A partir dos resultados obtidos, podemos sugerir que o IC
Cont e IC IAer parecem ser os métodos mais adequados para a melhoria da função
cardíaca e da disfunção barorreflexa na IC. / Purpose: To evaluate the effect of different methods of physicaltraining on cardiac
function and baroreflex sensitivity in anexperimental model of heart failure. Methods:
Male Wistar Kyoto rats (250 - 350g) were stratified into: continuoustraining (IC Cont),
anaerobic interval training (ICIAna), aerobic interval training (IC IAer) and sedentary
(IC Sed). The animals underwent surgery toinduce heart failureby ligation of the
interventricular coronary artery. Cardiac function was assessedby echocardiography 6
weeks after the procedure and at the end of training. The measurement of ejection
fraction and ventricular and atrial diameters was performed by Simpson's method and
module M, respectively. Before, in the fourth week and atthe end of training, rats
underwent a maximal effort test (ET) on a treadmill, which was characterized by the
initial speed of 10 m/min and gradually increased to 3 m/min every 2 minutes. The
physical training (8 weeks, 3 sessions/week, 30 min/session) started 6 weeks after
surgery. The IC Cont consisted in 70% of the maximum speed obtained in the ET. The
IC Ana was marked by alternating segments of 1 min at 90% and 50% of the maximum
speed on ET. Furthermore, the IC Aer was characterized by alternating periods of 5 min
at 80% and 60% of the maximum speed on ET. After the third ET, the animals were
anesthetized with urethane (1.5 mg/kg) and the left carotid artery and the right jugular
vein were catheterized, allowing the measurement of blood pressure (BP) and heart rate
(HR). The index of baroreflex sensitivity (IBS) was obtained by the reason of ΔHR and
ΔBP before and after doses of sodium nitroprusside (2.5, 5, 10 and 20 g/ml) and
phenylephrine (4, 8, 16 and 32 g/ml). Statistical analysis was performed by GraphPad
Prism, using the two-way ANOVA and Bonferroni post-test, considering statistically
significant p <0.05. Results: A significant increase in ejection fraction was found in IC
Cont (28.48±5 vs 39.2±11%) and IC IAer (31.03±7 vs 42±9%). As in regard of the
ventricular and atrial diameters, we did not observe any significant change in the trained
groups. However, the IC Sed demonstrated increased leftventricular diameter in
diastole (0.89 ± 0.09 vs 1 ± 0.1cm). Regarding the content of ISB, only the IC Cont
showed a higher rate than the IC Sed (1.65 ± 1 vs 0.82 ± 0.4 bpm / mmHg).
Conclusions: The results suggest that the IC IAerand IC Cont seem to be the most
appropriate methods for improving cardiac function. In addition, only IC Cont improved
baroreflex dysfunction in HF.

Identiferoai:union.ndltd.org:IBICT/oai:www.arca.fiocruz.br:icict/6060
Date January 2010
CreatorsMasson, Gustavo Santos
ContributorsOliveira, Gabriel Melo de, Michelini, Lisete Compagno, Soares, Pedro Paulo da Silva, Moraes, Roger de, Bonomo, Isabela, Lessa, Marcos Adriano da Rocha
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da FIOCRUZ, instname:Fundação Oswaldo Cruz, instacron:FIOCRUZ
RightsGustavo Santos Masson, info:eu-repo/semantics/openAccess

Page generated in 0.0029 seconds