Return to search

Avaliação da durabilidade de concretos produzidos com agregado reciclado de concreto frente à penetração de íons cloreto

Submitted by Mariana Dornelles Vargas (marianadv) on 2015-05-15T15:04:33Z
No. of bitstreams: 1
avaliacao_durabilidade.pdf: 4158024 bytes, checksum: 928f748af7e8e413bb72875a6df47592 (MD5) / Made available in DSpace on 2015-05-15T15:04:33Z (GMT). No. of bitstreams: 1
avaliacao_durabilidade.pdf: 4158024 bytes, checksum: 928f748af7e8e413bb72875a6df47592 (MD5)
Previous issue date: 2010-05 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / FINEP - Financiadora de Estudos e Projetos / A geração de resíduos causados pela construção civil e acrescente demanda de recursos naturais do setor vem resultando na utilização dos Resíduos de Construção e Demolição (RCD) como matéria prima. A prática do uso deste resíduo como agregado está sendo de extrema importância para o meio ambiente e para a sociedade de um modo geral. O escopo deste trabalho restringe-se ao estudo de agregado reciclado de concreto (ARC). As principais diferenças entre os agregados naturais e reciclados dizem respeito à porosidade e resistência à compressão, que podem influenciar diretamente tanto nas propriedades do concreto fresco, como nas propriedades do concreto endurecido, afetando a sua durabilidade. A porosidade do agregado de concreto reciclado influencia a sua absorção de água, o que pode alterar a demanda de água da mistura do concreto. Neste caso o processo de pré-molhagem pode ser adotado com o objetivo de compensar esta absorção e garantir a manutenção da consistência. Este trabalho tem por objetivo avaliar o comportamento de concretos produzidos com agregados reciclados de concreto (ARC) frente à penetração de íons cloreto. Foram produzidos ARC em laboratório com concretos de diferentes níveis de fc, 18 MPa (a/c de 0,85), 37 MPa (a/c 0,56) e 50 MPa (a/c 0,43). Estes agregados foram empregados em uma nova matriz de concreto com uma relação a/c de 0,64, substituindo o agregado natural pelo ARC em diferentes teores, 0, 25,50, 75 e 100%. Os agregados reciclados foram pré-molhados com cinco diferentes teores, de 0 a 100%. Foram realizados ensaios de resistência mecânica e de durabilidade, como resistência à compressão e à tração, absorção de água, absorção de íons cloreto e penetração acelerada de íons cloreto. O método empregado para verificar a resistência à penetração acelerada de íons cloreto foi o da norma ASTM C1202-07. A absorção de água e de íons cloreto empregou o método adapata do do proposto pelo RILEM TC 166-PCD. Os resultados foram avaliados por análise estatística, indicando que tanto o teor de agregado, como o teor de pré-molhagem apresentam efeitos significativos sobre a penetração de íons cloreto, enquanto que o tipo de agregado apresenta efeito quando em interação com outras variáveis de controle. Para as demais propriedades de durabilidade, as variáveis de controle apresentam a mesma tendência de comportamento. / The construction and demolition waste generation and the crescent natural resources demand by construction industry has led the use the use of Construction and Demolition Waste (CDW) as raw material. This practice is important for the environment conservation. The work scope concerns only to recycled concrete aggregate (ARC). The porosity and compressive strength are the main differences between natural and recycled aggregates. These facts influence fresh concrete and the hardened concrete properties, which can affect its durability and mechanical performance. The higher recycled concrete aggregate porosity causes higher water absorption than the natural aggregate, and the water demand of the concrete mix may will increased for the slump maintenance. The pre-wetting can be adopted in order to compensate this absorption and ensure the slump maintenance. The aim of this research is the durability assessment of concrete produced with recycled concrete aggregate by chloride ions penetration. ARC were produced in the laboratory with different levels of concrete compressive strength, 18 MPa (w/c 0.85), 37 MPa (w/c 0.56) and 50 MPa (w/c 0.43). Recycled aggregate were used as 25%, 50%, 75% and 100% replacements of natural coarse aggregate in the concrete mixtures. The ARC pre-wetting was conducted at five levels, from 0 to 100% by recycled aggregate total water absorption. The ARC compressive strength, ARC amounts and pre-wetting effects on the compressive and tensile strength, water absorption and chloride-ion penetration of concrete produced with recycled aggregate were investigated. It was used the Accelerated Resistance to Chloride Ion Penetration ASTM C 1202-97 Test Method and adapted RILEM TC-166 PCD Water Absorption Test Method. Data analysis was conduced using statistical analysis, including ANOVA and multiple regression. These analyses indicated the significant effect of ARC type and amount and prewetting level on the chloride ion penetration and water absorption. For the compressive strength the ARC type and amount have a significant effect, while for the tensile strength only the ARC amount has a significant effect.

Identiferoai:union.ndltd.org:IBICT/oai:www.repositorio.jesuita.org.br:UNISINOS/3549
Date27 May 2010
CreatorsTroian, Aline
Contributorshttp://lattes.cnpq.br/5195306459511343, Kulakowski, Marlova Piva
PublisherUniversidade do Vale do Rio dos Sinos, Programa de Pós-Graduação em Engenharia Civil, Unisinos, Brasil, Escola Politécnica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UNISINOS, instname:Universidade do Vale do Rio dos Sinos, instacron:UNISINOS
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0047 seconds