Desenvolvimento de dispositivo para calibraÃÃo de sensor de umidade do solo e aplicaÃÃo em sensores tipo tensiÃmetro eletrÃnico e resistÃncia elÃtrica / Development of apparatus for soil moisture calibration was developed and built (DCSUS) and application in sensors electronic type an electronic tensiometer and electric resistance.

FundaÃÃo de Amparo à Pesquisa do Estado do Cearà / Um dispositivo para calibraÃÃo de sensores de umidade do solo (DCSUS) foi desenvolvido. Para o controle da umidade do solo foram instalados um sistema de sucÃÃo tipo funil de placa porosa e um sistema de pressÃo tipo cÃmara de pressÃo. Foi construÃda uma estrutura de ferro de 3,0 m de altura, no topo da qual, uma balanÃa de braÃos conteve, em uma das extremidades, a coluna de solo horizontal com os sensores de umidade a serem calibrados e, na outra, uma cÃlula de carga com capacidade nominal de 490,33 N, para obtenÃÃo da
variaÃÃo do peso da coluna decorrente da perda de umidade. Os dados dos sensores de umidade, da cÃlula de carga e de um sensor de temperatura foram coletados em tempo real, no
perÃodo de 15/01 a 27/05/2004, a uma freqÃÃncia de 3 Hz, por um sistema de aquisiÃÃo de dados, cujo conversor analÃgico digital possuÃa canais de 12 bits. Os dados foram armazenados diariamente em um arquivo de texto para posterior processamento. Foi realizada a calibraÃÃo do dispositivo para determinaÃÃo de sua sensibilidade. Realizou-se o monitoramento da umidade do solo atravÃs dos registros da cÃlula de carga; da tensÃo da Ãgua do solo, atravÃs de cinco sensores tipo tensiÃmetros eletrÃnicos e da resistÃncia elÃtrica do solo, atravÃs de trÃs sensores de matriz granular (Watermark). Os dados da temperatura ambiente foram coletados pelo sensor de temperatura FM51. Foram analisadas as saÃdas obtidas na cÃlula de carga e nos sensores de umidade do solo quanto à variaÃÃo da temperatura ao longo do dia. O DCSUS apresentou sensibilidade para variaÃÃo de umidade correspondente à perda de 13,33 mL de Ãgua. A cÃlula de carga utilizada apresentou
sensibilidade à temperatura ambiente ao longo do dia, com erro em torno de 0,25%. Nas condiÃÃes experimentais estabelecidas, os sensores Watermark nÃo apresentaram erro devido à temperatura ambiente. Os tensiÃmetros apresentaram erro devido à variaÃÃo da temperatura acima de 3,5% quando em potenciais mÃtricos mais elevados (-3,87 kPa) e acima de 5,5 %
quando em potenciais mÃtricos mais baixos (-44,50 e 51,00 kPa). O DCSUS desenvolvido foi eficaz quanto à determinaÃÃo da umidade do solo, com sensibilidade à variaÃÃo de 4,244.10-4 cm3.cm-3. / Na apparatus for soil moisture calibration was developed and built (DCSUS). The moisture was controlled indirectly by controlling the soil water matrix potenctial using both a
porous plate funnel and a pressure chamber system. A 3.0 m high tower wal built in steel and a scale installed on its top. The scale components were an I-bean articulated in its center by a set of bearings and bushings and a shaft. The bian was welded in its middle point to the shaft and a horizontal soil column with undisturbed soil contained by an acrylic cylinder installed on one of its ends, and a 50 N capacy load cell on the other end. The following sensors were installed: a granular matrix sensor (Watermark), an electronic tensiometer sensor, air temperature sensors and soil temperature sensors. Moisture sensor readings, as well as from the load cell and temperature sensor were taken in real time at a 3 Hz frequency from 01/15 to 05/27/2004. The data acquisition system was made of a 12-bit analog/digital coverter, an AMD188 microcontroller and an RS232 interface. Data was stored daily and applied to obtain the parameters of calibrations, sensitivity and the effect of temperature on the system. The apparatus resulted in sensitivity to moisture change of 13,33 mL of water. The load cell displayed some sensitivity to daily temperature variation, with an error of 0,25%. The Watermark sensors were not affected by air temperature variation, but displayed sensitivity to variation on the supplied voltage. The electronic tensiometers, however, were more sensitive to temperature with errors of 3.5% for higher matric potentials (-3.82 to -3.92 kPa) and 5.5% for lower matric potentials (-44.5 to -51 kPa). The DCSUS showed to be efficient in monitoring variations soil moisture, displaying a minimum reading 4.244E-4 cm3.cm-3.

Identiferoai:union.ndltd.org:IBICT/oai:www.teses.ufc.br:2125
Date01 September 2004
CreatorsRaimundo AlÃpio de Oliveira LeÃo
ContributorsAdunias dos Santos Teixeira, Renato SÃlvio da Frota Ribeiro, FÃbio Rodrigues de Miranda
PublisherUniversidade Federal do CearÃ, Programa de PÃs-GraduaÃÃo em Engenharia AgrÃcola, UFC, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UFC, instname:Universidade Federal do Ceará, instacron:UFC
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0018 seconds