nÃo hà / The research aimed to evaluate the performance of sewage treatment plants septic-type anaerobic filters located in the state of Rio Grande do Norte and its study of post-treatment technique runoff aimed at removing nutrients (N and P) and pathogens, tailoring the physico-chemical and microbiological standards required for the reuse and considering legislation to launch in the receptor fluid, evaluating such studies in the temporal / spatial having spineless cactus (Opuntia ficus-indica (L.) Mill) as plant species grown on the slopes of runoff. For this work we used the cactus pear (Opuntia ficus indica L.Mill) because it has great adaptation to drought and strong native to northeastern Brazil, as well as the uniqueness in the cultivation of aquatic vegetation using domestic sewage. The survey was conducted in Santa Maria, located in Wastewater Treatment Plant of in Santa Maria, Rio Grande do Norte. Ramps were built three runoff with different slopes, 2%, 4% and 8% with 30 meters long and 10 meters further on ramp 8% incline. The liquid was applied to the ramps sewage in nature, with primary treatment and secondary treatment, from septic tanks and anaerobic filters. Application rates of sewage tested were 0.20 m / hm, 0.30 m / hm and 0.4 m / hm. We evaluated the ability of the system to remove nutrients, nitrogen and phosphorus as well as organic matter. With the realization of quantitative analysis was possible to determine which slope allowed greater removal and which operating flow. Of the three steps, the rate of 0.40 m / hm and inclination of 8% showed the best efficiency, being 93.55% and the concentration of 25.67 mg / L for BOD, 56.10% and concentration of 17.65 mg / L for N-total, 25.94% and the concentration of 5.98 mg / L for P -total, 4 logs and 1.89 x103 NMP/100mL concentration of coliforms and 22.20% to 534.29 final concentration μS / cm electrical conductivity. The influent wastewater to the WTP parameters of BOD, N-total, P-total coliforms Thermotolerant and Electrical Conductivity for the 3rd stage were 398.12 mg / L, 40.22 mg / L, 8.08 mg / L; 2.81 x107NMP / 100mL and 686.75 mS / cm respectively. A septic tank and anaerobic filter, and the post-treatment system had values within the range mentioned in the literature were 34.68% and the final concentration of 260.02 mg / L, 78.61% and the final concentration of 85.14 mg / L to 93.55% and the final concentration of 25.67 mg / L respectively, for the best rate of application was 0.40 m / um and a gradient of 8%. In all aspects examined, the system has improved the quality of the final effluent, showing up as an alternative, with simple, inexpensive technique compatible with the economic reality of the Brazilian Northeast, although the rate of 0.20 m / hm and 0.30 m / hm showed a slightly lower efficiency of 0.40 m / um, they can not be discarded, since the values found are partially within the ranges quoted in the literature. / A pesquisa teve como objetivo avaliar o desempenho de ETEs do tipo fossas sÃpticas-filtros anaerÃbios localizados no Estado do Rio Grande do Norte, tendo como estudo de pÃs-tratamentos a tÃcnica de escoamento superficial com vistas à remoÃÃo de nutrientes (N e P) e patÃgenos, buscando-se adequar as caracterÃsticas fÃsico-quÃmicas e microbiolÃgicas aos padrÃes exigidos para o reuso e atender a legislaÃÃes para lanÃamento em corpo receptor hÃdrico. Tais estudos foram avaliados nas escalas temporal/sazonal, tendo a palma forrageira (Opuntia fÃcus-indica (L.) Mill) como espÃcie vegetal cultivada nas rampas de escoamento superficial. Para este trabalho, foi utilizada a referida espÃcie de palma, por ser esta de fÃcil adaptaÃÃo Ãs fortes estiagens e ser nativa no Nordeste Brasileiro, e tambÃm pelo ineditismo no cultivo dessa vegetaÃÃo com o uso de esgotos domÃsticos. A pesquisa foi realizada na ETE Santa Maria, localizada no municÃpio de Santa Maria, Rio Grande do Norte. Foram construÃdas trÃs rampas de escoamento superficial com inclinaÃÃes diferentes, 2%, 4% e 8% com 30 metros de comprimento e 10 metros adicionais na rampa de 8% de inclinaÃÃo. O lÃquido aplicado nas rampas era esgoto sanitÃrio in natura, com tratamento primÃrio e com tratamento secundÃrio, proveniente de fossas sÃpticas e filtros anaerÃbios. As taxas de aplicaÃÃo de esgoto testadas foram 0,20mÂ/h.m, 0,30mÂ/h.m e 0,4mÂ/h.m. Avaliou-se a capacidade do sistema em remover nutrientes, nitrogÃnio e fÃsforo, bem como matÃria orgÃnica. Com a realizaÃÃo de anÃlises quantitativas, foi possÃvel determinar qual inclinaÃÃo permitia maior remoÃÃo e em qual vazÃo de operaÃÃo. Das trÃs etapas, a taxa de 0,40mÂ/h.m e inclinaÃÃo de 8% foi a que apresentou melhores eficiÃncias, sendo 93,55% e concentraÃÃo de 25,67mg/L para DBO; 56,10% e concentraÃÃo de 17,65mg/L para N-Total; 25,94% e concentraÃÃo de 5,98mg/L para P-total; 4 logs e concentraÃÃo de 1,89x103NMP/100mL de coliformes termotolerantes e 22,20% e concentraÃÃo final de 534,29μS/cm de condutividade elÃtrica. O esgoto afluente à ETE para os parÃmetros de DBO, N-Total, P-total, Coliformes Termotolerantes e Condutividade elÃtrica para a 3 etapa foram 398,12mg/L; 40,22mg/L; 8,08mg/L; 2,81x107NMP/100mL e 686,75μS/cm, respectivamente. A fossa sÃptica e o filtro anaerÃbio, bem como o sistema de pÃs-tratamento, apresentaram valores de DBO dentro da faixa citada pela literatura, a saber: 34,68% e concentraÃÃo final de 260,02mg/L; 78,61% e concentraÃÃo final de 85,14mg/L e 93,55% e concentraÃÃo final de 25,67mg/L para a 1Â, 2 e 3 etapas, respectivamente. A melhor taxa de aplicaÃÃo foi a de 0,40mÂ/h.m e declividade de 8%. Em todos os aspectos analisados, o sistema melhorou a qualidade final do efluente, mostrando-se como alternativa, com tÃcnica simples e barata compatÃvel com a realidade econÃmica do nordeste brasileiro. Embora as taxas de 0,20mÂ/h.m e 0,30mÂ/h.m tenham apresentado uma eficiÃncia um pouco abaixo da 0,40mÂ/h.m, estas nÃo podiam ser descartadas, uma vez que os valores encontrados encontravam-se parcialmente dentro das faixas citadas pela literatura. Quanto aos parÃmetros de morfometria, a palma forrageira teve crescimento dentro dos limites encontrados pela literatura tÃcnica, para o comprimento, nÃmero de cladÃdios, largura, espessura, IAC e altura do cladÃdio, sendo as taxas de aplicaÃÃo de efluentes de 0,40mÂ/h.m e declividade de 2% as que mostraram melhores resultados.
Identifer | oai:union.ndltd.org:IBICT/oai:www.teses.ufc.br:7826 |
Date | 21 March 2014 |
Creators | Pedro Alves da Silva Filho |
Contributors | Ronaldo Stefanutti, Francisco SuetÃnio Bastos Mota, Ana BÃrbara de AraÃjo Nunes, Silvano Porto Pereira, Maria Josà Nascimento Soares |
Publisher | Universidade Federal do CearÃ, Programa de PÃs-GraduaÃÃo em Engenharia Civil, UFC, BR |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Format | application/pdf |
Source | reponame:Biblioteca Digital de Teses e Dissertações da UFC, instname:Universidade Federal do Ceará, instacron:UFC |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0019 seconds