Return to search

Ausência de correlação entre a penetração do cimento AH Plus nos túbulos dentinários e a qualidade do selamento / Lack of correlation between AH Plus sealer penetration into dentinal tubules and sealability

O presente estudo objetivou testar experimentalmente a existência da possível correlação entre a penetração de cimento nos túbulos dentinários e a qualidade do selamento. Foram utilizados 60 incisivos centrais superiores humanos que formaram um único grupo experimental. Após a eliminação das porções coronárias, as raízes foram padronizadas em 13 mm de comprimento. A instrumentação dos canais foi realizada no sentido coroa-ápice, e o comprimento de trabalho estabelecido a 1 mm aquém do forame apical. Como solução irrigadora foi empregado o NaOCl a 5,25% e ao final, EDTA a 17%. Em seguida, todos os canais foram obturados com guta-percha e cimento AH Plus marcado com um corante fluorescente. Para determinar a qualidade do selamento das obturações endodônticas, as amostras foram submetidas ao modelo de infiltração de glicose sob pressão. As raízes foram montadas em um dispositivo de dupla-câmara selada para permitir a infiltração da glicose. Como controle negativo foram utilizados 4 dentes hígidos, e como controle positivo, 2 dentes instrumentados porém, não obturados. Foram utilizados 0,75 mL de solução de glicose a 1 mol/L na câmara superior e 0,75 mL de água deionizada na câmara inferior. Os dispositivos foram conectados a um sistema de distribuição de pressão desenvolvido com o objetivo de permitir a infiltração de 32 amostras em uma mesma etapa. A solução de glicose foi forçada apicalmente sob uma pressão de 15 psi durante 1 hora. Uma alíquota de 50 L foi coletada da câmara inferior para quantificar a glicose infiltrada. A concentração de glicose foi determinada através de um método enzimático com o auxílio do Kit Glucose HK e de um espectrofotômetro em um comprimento de onda de 340 nm. Na sequência, as amostras foram desacopladas dos corpos de prova, embutidas em resina epóxi e cortadas em 3 secções transversais. Uma sequência de preparação metalográfica padrão foi realizada para permitir a observação da penetração de cimento nos túbulos dentinários por meio de microscopia confocal e óptica. Os dados obtidos nos 2 experimentos foram cruzados pelo teste de correlação de Spearman, o qual revelou a inexistência de qualquer possibilidade de correlação (r = 0,12). Com base nesses resultados, o presente trabalho concluiu que, dentro das condições experimentais usadas, a quantidade de cimento presente dentro dos túbulos dentinários não teve relação com a qualidade do selamento produzido. / The purpose of the present study was to experimentally test the potential correlation between tubular dentin sealer penetration and sealability. Sixty human maxillary central incisors were selected in order to compose a single experimental group. After removing of crowns, the roots were standardized at 13 mm in length. A crown-down root canal instrumentation was performed 1mm short of the apical foramen (working length). How irrigating solution was used 5.25% NaOCl and final, 17% EDTA. Then, all root canals were filled with gutta percha and AH Plus sealer labeled with a fluorescent dye. To determine the sealability pattern, samples were submitted to glucose leakage model under pressure. Four intact teeth were used as negative control while further 2 instrumented but nonfilled teeth was used as positive control. The roots were mounted in a double-chamber apparatus where 0,75 mL of 1 mol/L glucose solution was placed into the superior chamber and 0,75 mL of deionized water was placed into the inferior chamber. The devices were connected to a pressure distribution system that was developed in order to allow testing 32 specimens at the same experimental stage. The glucose solution was forced apically under a pressure of 15 psi during 1 hour. A sample of 50 L was taken from the inferior chamber and the glucose concentration was measured following an enzymatic reaction using a Glucose HK Kit readed under spectrophotometry (wave-length of 340 nm). After that, the samples were removed from the apparatus, embedded in epoxy resin and cut into 3 sections. Standard metallographic preparation was performed prior the observation of the sealer penetration into dentinal tubules by confocal and optical microscopy. Data provided by the evaluations were submitted to Spearman correlation test which revealed a lack of correlation between the two variables (r = 0.12). Therefore, the present study concluded that there was no correlation between tubular sealer penetration and sealability in non-bonding conventional root-fillings.

Identiferoai:union.ndltd.org:IBICT/urn:repox.ist.utl.pt:BDTD_UERJ:oai:www.bdtd.uerj.br:1505
Date30 March 2010
CreatorsMaria Cláudia Brandão de Souza
ContributorsRivail Antonio Sergio Fidel, Gustavo André de Deus Carneiro Vianna, Sandra Rivera Fidel, Tauby de Souza Coutinho Filho, Manoel Damião de Sousa Neto
PublisherUniversidade do Estado do Rio de Janeiro, Programa de Pós-Graduação em Odontologia, UERJ, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UERJ, instname:Universidade do Estado do Rio de Janeiro, instacron:UERJ
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0031 seconds