Return to search

Seismic Retrofit of Load Bearing Masonry Walls with Surface Bonded FRP Sheets

A large inventory of low rise masonry buildings in Canada and elsewhere in the world were built using unreinforced or partially reinforced load bearing wall. The majority of existing masonry structures is deficient in resisting seismic force demands specified in current building codes. Therefore, they pose significant risk to life safety and economic wellbeing of any major metropolitan centre. Because it is not economically feasible to replace the existing substandard buildings with new and improved structures, seismic retrofitting remains to be an economically viable option.
The effectiveness of surface bonded carbon fiber-reinforced polymer (CFRP) sheets in retrofitting low-rise load bearing masonry walls was investigated in the current research project. The retrofit technique included the enhancements in wall capacity in shear and flexure, as well as anchoring the walls to the supporting elements through appropriate anchorage systems. Both FRP fan type anchors and steel sheet anchors were investigated for elastic and inelastic wall response. One partially reinforced masonry (PRM) wall and one unreinforced masonry (URM) wall were built, instrumented and tested under simulated seismic loading to develop the retrofit technique. The walls were retrofitted with CFRP sheets applied only on one side to represent a frequently encountered constraint in practice. FRP fan anchors and stainless steel sheet anchors were used to connect the vertical FRP sheets to the wall foundation. The walls were tested under constant gravity load and incrementally increasing in-plane deformation reversals. The lateral load capacities of both walls were enhanced significantly. The steel sheet anchors also resulted in some ductility. In addition, some small-scale tests were performed to select appropriate anchor materials. It was concluded that ductile stainless steel sheet anchors would be the best option for brittle URM walls.
Analytical research was conducted to assess the applicability of truss analogy to retrofitted walls. An analytical model was developed and load displacement relationships were generated for the two walls that were retrofitted. The analytical results were compared with those obtained experimentally, indicating good agreement in force resistance for use as a design tool.

Identiferoai:union.ndltd.org:LACETR/oai:collectionscanada.gc.ca:OOU.#10393/24233
Date07 June 2013
CreatorsArifuzzaman, Shah
Source SetsLibrary and Archives Canada ETDs Repository / Centre d'archives des thèses électroniques de Bibliothèque et Archives Canada
LanguageEnglish
Detected LanguageEnglish
TypeThèse / Thesis

Page generated in 0.002 seconds