Return to search

Design and Development of an Apparatus to Study Aviation Jet Fuel Thermal Stability

A single tube flow heat exchanger was designed and built to thermally stress Jet A-1 with air-saturated and deoxygenated levels of dissolved oxygen over a range of fuel temperatures, pressures, and flow rates. Liquid samples of thermally degraded Jet A-1 were analyzed using various physical and optical methods to determine which methods were sensitive enough to measure compositional changes in thermally degraded liquid fuel and to correlate these changes to the measured amount of deposits produced. Temperature programmed oxidation (TPO) was shown to be successful in measuring deposit quantity and structure, while UV-visible absorption and UV-visible fluorescence were sensitive enough to quickly measure the relative population growth of large aromatic compounds that lead to deposit formation in thermally stressed Jet A-1.

Identiferoai:union.ndltd.org:LACETR/oai:collectionscanada.gc.ca:OTU.1807/25521
Date30 December 2010
CreatorsWong, Owen
ContributorsGulder, Omer L.
Source SetsLibrary and Archives Canada ETDs Repository / Centre d'archives des thèses électroniques de Bibliothèque et Archives Canada
Languageen_ca
Detected LanguageEnglish
TypeThesis

Page generated in 0.0022 seconds