Return to search

Structural health monitoring of the Traffic Bridge in Saskatoon using strain gauges

The steel through-truss Traffic Bridge, located in Saskatoon, Saskatchewan is over one hundred years old. The bridge has been subject to ongoing maintenance throughout its service life. However, inspection reports from 2005 and 2006 highlighted the severe deterioration experienced primarily by the steel members immediately above and below the deck surface. These reports prompted the City of Saskatoon (COS) to implement a rehabilitation project that involved the installation of a post-tensioning system to relieve the badly corroded bottom chord members of the axial loads due to the self-weight of the structure, in 2006. Due to the severe deterioration and the structural modifications that the Traffic Bridge has endured, a limited scope structural health monitoring (SHM) system, based on strain measurements, was implemented to reduce some of the uncertainty regarding the active load paths occurring at the deck level.
The objectives of the SHM study were to obtain more information regarding the actual load paths and ascertain possible types of structural redundancy, to determine how to best model this type of structure, and to find ways to track ongoing deterioration using instrumentation. The SHM study involved controlled truck loading scenarios to permit measurement of the load paths and provide data to compare the measured results to a finite element (FE) model of the instrumented span. In addition, random loading scenarios were used to capture the vertical dynamic response of the structure in order to further refine the FE model.
This study focused on the response of one-half of one interior span. A total of 72 strain gauges were installed. The downstream truss was highly instrumented at ten locations, three members of the upstream truss were instrumented to measure the distribution, and the floor joists in the downstream lane were instrumented to establish possible redundancy paths.
Using an FE model in combination with the measured strain data, it was found that redundant load paths only existed at the level of the deck. The bottom chord members experienced non-zero strains once the control vehicle was past the span, possibly indicating some level of redundancy. The members believed to relieve a portion of the bottom chord tensile forces included the car joists, edge joists, and the timber deck. The amount of force transferred from the bottom chord to the deck members was found by FE analysis to be highly related to the lateral stiffness of the floor beams.
The FE model was adjusted to match the measured results by modifying various modelling parameters. The most important features of the model were that all deck elements were modelled to be located at the elevation of the bottom chord, that the lateral stiffness of the floor beams was reduced by 50% to best represent the transfer of forces to deck elements, and that the stiffness of bottom chord members was reduced to 80% of their pristine values. In combination with calibrated modification factors applied to the measured values, this FE model is believed to be a useful tool to represent the behaviour of the structure to assist in detecting further damage by modelling the strain differential between members, and components of members.

Identiferoai:union.ndltd.org:LACETR/oai:collectionscanada.gc.ca:SSU.etd-04122011-161104
Date15 April 2011
CreatorsMacLeod, Alison Barbara
ContributorsSparks, Gordon, Afseth, Jeff, Boulfiza, Mohamed, Feldman, Lisa, Wegner, Leon, Sparling, Bruce
PublisherUniversity of Saskatchewan
Source SetsLibrary and Archives Canada ETDs Repository / Centre d'archives des thèses électroniques de Bibliothèque et Archives Canada
LanguageEnglish
Detected LanguageEnglish
Typetext
Formatapplication/pdf
Sourcehttp://library.usask.ca/theses/available/etd-04122011-161104/
Rightsunrestricted, I hereby certify that, if appropriate, I have obtained and attached hereto a written permission statement from the owner(s) of each third party copyrighted matter to be included in my thesis, dissertation, or project report, allowing distribution as specified below. I certify that the version I submitted is the same as that approved by my advisory committee. I hereby grant to University of Saskatchewan or its agents the non-exclusive license to archive and make accessible, under the conditions specified below, my thesis, dissertation, or project report in whole or in part in all forms of media, now or hereafter known. I retain all other ownership rights to the copyright of the thesis, dissertation or project report. I also retain the right to use in future works (such as articles or books) all or part of this thesis, dissertation, or project report.

Page generated in 0.0796 seconds