Return to search

Energy neutral operation method for hybrid energy storage integrated with wind farm using C-rate and frequency spectrum analysis

<p> In this thesis, the author describes various evaluation criteria, in particular the C-rate (charge/discharge-rate), of energy storage (ES) systems to explain the efficiency and technical benefits of battery-ultracapacitor hybrid energy storage (HES), and the technical characteristics of subsequently derived short-duration and long-duration type ES. In addition, for effective use of energy storage, a straightforward state of charge (SOC) correction method for energy neutral operation is proposed, and through a simple comparative example of ES operation, the effectiveness of HES in relation to simple ES is explained. A case is considered in which a hybrid ES controls the wind power ramp rate to comply with the regional system operator&rsquo;s smoothing requirement, and an operation method is suggested through simulation. The simulation is carried out using a frequency spectrum analysis of wind power output profile and the C-rate of the hybrid storage system, and an energy neutral operation method for ES is proposed based on the simulated charging/discharging power sharing profile and SOC variations of the Li-battery and the ultracapacitor. </p>

Identiferoai:union.ndltd.org:PROQUEST/oai:pqdtoai.proquest.com:1592297
Date24 July 2015
CreatorsSeo, Young-Jun
PublisherThe University of Wisconsin - Milwaukee
Source SetsProQuest.com
LanguageEnglish
Detected LanguageEnglish
Typethesis