Estimation of the Heat Transfer Coefficient on the Fin of the Finned-Elliptic Tube Evaporator under Frosting Conditions with Experimental Data / 利用逆算法配合實驗數據預測橢圓鰭管式熱交換器之鰭片於結霜狀態下的熱傳遞係數

碩士 / 國立成功大學 / 機械工程學系碩博士班 / 91 / The main task of the thesis is to estimate the heat transfer coefficient on the plate finned-tube evaporator under frosting condition. Researches will include numerical and experimental works; the numerical work is to present the heat transfer coefficient under forced convection, and the experimental work is to obtain the temperature data.
The numerical method based on the hybrid scheme of the Laplace transform method and central different method in conjunction with the least-squares scheme is used to solve the two-dimensional inverse heat conduction problems for evaluating heat transfer coefficient. The least-squares minimization technique is applied to minimize the sum of the squares of the deviations between the calculated and curve-fitted temperature measurements. In the inverse heat conduction problem, slight inaccuracies in the measured interior temperatures can affect the accuracy of estimated the thermal properties. Thus the effect of measurement errors on the estimation of heat transfer coefficient will be investigated in the present analysis. A plate finned-tube evaporator is set up in conjunction with the other experimental equipment for measuring the frost thickness and tube temperature. The heat transfer coefficient and heat flux on the fin under frosting condition can be determined by using the present numerical method and the temperature measurements.

Identiferoai:union.ndltd.org:TW/091NCKU5490151
Date January 2003
CreatorsKuo-Wen Wu, 吳國文
ContributorsHan-Taw Chen, 陳寒濤
Source SetsNational Digital Library of Theses and Dissertations in Taiwan
Languagezh-TW
Detected LanguageEnglish
Type學位論文 ; thesis
Format58