The Parametric Study on Heat Exchanger Fins of Solar Ventilation Device / 太陽能通風設備的熱交換鰭片參數化研究

碩士 / 國立成功大學 / 航空太空工程學系碩博士班 / 97 / The present study is to extend the work of Jin-Han Liu on heat pipe based solar ventilation device. The main purpose of the study is to discuss the effects of height and number of heat exchanger fins on the ventilation. The approach of study is similar to that used in Liu’s research, which employed simulated solar radiation with heating device. Heat pipes were used to transport the heat from heat absorber to heat exchanger fins and create natural convection ventilation effect.
The test bed has a 0.6m2 heat absorber with preset 600W heating and 8 syphon type heat pipes of 8mm in diameter laid on the absorber to transport the heat. The fins has 3mm thickness, with 3 different heights (5cm, 10cm, and 20cm), and different numbers (15, 30, 45, and 60).
Temperature measurements were conducted on heat pipes, fins, and at the exit of the vented duct with flow velocity measured. The results showed that the vented heat is proportional to the number of fins, and is also proportional to the height of fins. It was found that the best ventilation result in the study lies at 45 fins and 10cm fin height.

Identiferoai:union.ndltd.org:TW/097NCKU5295005
Date January 2009
CreatorsYou-Zen Lin, 林宥任
ContributorsShih-Hsiung Chen, 陳世雄
Source SetsNational Digital Library of Theses and Dissertations in Taiwan
Languagezh-TW
Detected LanguageEnglish
Type學位論文 ; thesis
Format139

Page generated in 0.0015 seconds