Return to search

Characteristics of dielectric-loaded coaxial cables.

The characteristics of all modes in the dielectric-loaded coaxial cable have been given. Reduction in attenuation by dielectric loading is possible for the dominant mode in these cables, including -cables with optimum-dimensions, if lossless or sufficiently low-loss dielectrics are used. For higher losses in the loading dielectric, higher frequencies are required to achieve attenuation reduction. No significant reduction in conductor losses can be achieved with cables whose dimensions are such that only the dominant mode can be supported.
Measurements of the attenuation coefficients of several lower order modes were carried out at S-band frequencies using a resonant cavity. Experimental observations agree favorably with theory for the TM modes. / Applied Science, Faculty of / Electrical and Computer Engineering, Department of / Graduate

Identiferoai:union.ndltd.org:UBC/oai:circle.library.ubc.ca:2429/33522
Date January 1972
CreatorsLau, Ming Chee
PublisherUniversity of British Columbia
Source SetsUniversity of British Columbia
LanguageEnglish
Detected LanguageEnglish
TypeText, Thesis/Dissertation
RightsFor non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.