Return to search

Reprodutibilidade da curva de pressão intraocular de 24 horas em pacientes com glaucoma e suspeita de glaucoma /

Orientador: Hamilton Almeida Rollo / Coorientador: Maria Rosa Bet de Moraes Silva / Banca: Edson Nacib Jorge / Banca: Ralph Cohen / Banca: José Paulo Cabral de Vasconcellos / Banca: Maria de Lourdes Veronese Rodrigues / Resumo: Foi avaliada a reprodutibilidade das medidas de pressão intraocular (PIO) nos mesmos horários da curva tensional diária (CTD) de 24 horas, com três repetições. Foram estudados 33 indivíduos com glaucoma e suspeita de glaucoma sem tratamento. Todos os participantes foram submetidos a 3 CTDs de 24 horas. Os pacientes foram internados e as medidas foram realizadas às 9:00 hs, 12:00 hs, 15:00 hs, 18:00 hs, 21:00 hs, 24:00 hs e 6:00 hs com tonômetro de aplanação de Goldmann (TAG). A medida das 6:00 hs também foi realizada no leito, utilizando-se um tonômetro manual de Perkins antes da medida com o TAG. Uma segunda CTD de 24 horas foi realizada após um intervalo entre uma e três semanas e uma terceira após mesmo intervalo. A reprodutibilidade foi avaliada em cada horário da CTD de 24 horas com o coeficiente de correlação intraclasse (CCI) e os gráficos de Bland- Altman. Nos gráficos de Bland-Altman considerou-se como limite de concordância uma diferença de até 3 mmHg entre as medidas. O CCI variou de 0,736 a 0,917 nos diferentes horários, estando a maioria deles acima de 0,800. Nos gráficos de Bland- Altman, a porcentagem de pontos dentro do limite de concordância de 3 mmHg variou de 72,7 a 97,0%, sendo na maioria das observações acima de 80%. Concluiuse que as medidas da PIO em cada momento da CTD de 24 horas nas três repetições apresentaram excelente ou boa reprodutibilidade em indivíduos com glaucoma e suspeita de glaucoma / Abstract: The reproducibility of measurements of intraocular pressure (IOP) at the same points of the 24-hour daily tension curve (DTC) with three replications was evaluated. Thirtythree untreated subjects with glaucoma and suspected glaucoma were studied. All participants underwent three 24-hour DTCs. Briefly, participants were hospitalized and IOP measurements obtained at 9:00 AM, noon, 3:00 PM, 6:00 PM, 9:00 PM, midnight and 6:00 AM using a Goldmann applanation tonometer. The 6:00 AM measurement was also obtained at bedside with a handheld Perkins tonometer prior to Goldmann tonometry. A second 24-hour DTC was performed 1 to 3 weeks after the first, and a third and final curve was obtained 1 to 3 weeks after the second. Reproducibility of measurements at each time point of the 24-hour DTC was assessed by means of the intraclass correlation coefficient (ICC) and Bland-Altman plots. A 3-mmHg difference in IOP was defined as the limit of agreement for Bland- Altman plots. ICCs ranged from 0.736 to 0.917 at different time points, with the majority exceeding 0.800. The percentage of points within the 3-mmHg limit of agreement on Bland-Altman plots ranged from 72.7% to 97.0%, exceeding 80% in most cases. In conclusion, in patients with glaucoma or suspected glaucoma, IOP measurements obtained at each time point of the 24-hour DTC showed good or excellent reproducibility across the three curves performed / Doutor

Identiferoai:union.ndltd.org:UNESP/oai:www.athena.biblioteca.unesp.br:UEP01-000858467
Date January 2015
CreatorsHashimoto, Mitsuo.
ContributorsUniversidade Estadual Paulista "Júlio de Mesquita Filho" Faculdade de Medicina.
PublisherBotucatu,
Source SetsUniversidade Estadual Paulista
LanguagePortuguese
Detected LanguagePortuguese
Typetext
Format78 f.
RelationSistema requerido: Adobe Acrobat Reader

Page generated in 0.0025 seconds