Return to search

Strength evaluation of strut-purlins

Diaphragm braced strut-purlins are commonly used in the roof systems of metal buildings. However, the design problem of combined uplift and axial loads on these members is not adequately addressed in the 1989 AISI specification. The objective of this thesis is to provide experimental evidence that strut-purlins can be designed with an existing interaction equation. It was a/so the objective of this thesis to find a method of determining the axial capacity of diaphragm braced strut-purlins and to experimentally verify the accuracy of the method. / Master of Science

Identiferoai:union.ndltd.org:VTETD/oai:vtechworks.lib.vt.edu:10919/42564
Date09 May 2009
CreatorsHatch, Gerald L.
ContributorsCivil Engineering, Murray, Thomas M., Easterling, William Samuel, Holzer, Siegfried M.
PublisherVirginia Tech
Source SetsVirginia Tech Theses and Dissertation
LanguageEnglish
Detected LanguageEnglish
TypeThesis, Text
Formatvii, 270 leaves, BTD, application/pdf, application/pdf
RightsIn Copyright, http://rightsstatements.org/vocab/InC/1.0/
RelationOCLC# 22682877, LD5655.V855_1990.H377.pdf

Page generated in 0.0019 seconds