Return to search

A Computational Model for Predicting Visual Acuity from Wavefront Aberration Measurements

The main purpose of this thesis is to create and validate a visual acuity model with
experimentally obtained aberrations of human eyes. The other motivation is to come up with a
methodology to objectively predict the potential benefits of photorefractive procedures such as
customized corrections and presbyopic LASIK treatments.
A computational model of visual performance was implemented in MATLAB based on a
template matching technique. Normalized correlation was used as a pattern matching algorithm.
This simulation describes an ideal observer limited by optics, neural filtering, and neural noise.
Experimental data in this analysis were the eye’s visual acuity (VA) and 15 modes of Zernike
aberration coefficients obtained from 3 to 6 year old children (N=20; mean age= 4.2; best
corrected VA= 0 (in log MAR units)) using the Welch Allyn Suresight instrument. The model
inputs were Sloan Letters and the output was VA. The images of Sloan letters were created at
LogMAR values from -0.6 to 0.7 in steps of 0.05. Ten different alphabet images, each in ten
sizes, were examined in this model. For each simulated observer the results at six noise levels
(white Gaussian noise) and three levels of threshold (probability of the correct answer for the
visual acuity) were analyzed to estimate the minimum RMS error between the visual acuity of
model results and experimental result.

Identiferoai:union.ndltd.org:WATERLOO/oai:uwspace.uwaterloo.ca:10012/4704
Date January 2009
CreatorsFaylienejad, Azadeh
Source SetsUniversity of Waterloo Electronic Theses Repository
LanguageEnglish
Detected LanguageEnglish
TypeThesis or Dissertation

Page generated in 0.0021 seconds