Return to search

Developing P(MMA-co-NVP) hydrogels for use in self-inflating, anisotropic tissue expanders

Artificial tissue expansion is required to generate new skin prior to reconstructive surgery, in order to compensate for a deficit of healthy tissue. Hydrogel tissue expanders, which expand anisotropically, show great promise in overcoming clinical limitations in the field, thus allowing the technique to be used in a wider range of surgeries. These devices consist of pellets of dry poly(methyl methacrylate-co-vinylpyrrolidone), compressed into discs through a hot compression moulding process. However, a number of significant problems still exist in these devices, and this thesis aims to address these issues. To date, there has been a lack of investigation of the factors governing the behaviour of anisotropic swelling. For this reason, a range of different compression ratios have been investigated, with particular focus on the relationship between the material flow during compression and the swelling behaviour of the resulting device. It was found that samples of the same initial size expand to the same reference swelling dimensions, regardless of compression ratio. During hot pressing, the material flow was found to be governed by slip-stick behaviour at the interface between the hot press and the device, affecting the properties and swelling behaviour of the devices. Based on these findings, devices were developed which could expand from a disc into a non-prismatic shape (dome or wedge). Such devices could reduce complication rates and allow the growth of new tissue with anisotropic resting tension. The devices were tested in a small in vivo trial, where it was shown that there were no adverse effects on the tissue produced, and that the shape of the expander (dome) was retained. As devices are being produced for medical use, understanding the effect of sterilization by γ-irradiation is essential, but to date this has been overlooked in the literature. It was found that γ-irradiation caused an increase in cross-linking in the P(MMA-co-NVP). Whilst this produced little change in swelling behaviour for isotropic devices, in the case of anisotropic devices it caused a change in the shape of expansion, reducing the area of new skin which could be generated by the device. It was found that by reducing the concentration of impurities (residual molecules from the polymer synthesis) the impact of γ-irradiation could be greatly reduced. Finally, controlling the rate of expansion is essential in order to avoid clinical complications. In order to control the rate of expansion, particularly during the initial period of swelling, semi-permeable PDMS coatings were applied to the compressed devices. Coatings of thickness greater than 0.375mm were found to effectively control the rate of swelling, for both cylindrical and non-prismatic shapes. As the coating thickness increased, the maximum swelling size decreased. However, it has been shown that change in height (the parameter which governs the area of skin produced) is affected less than the change in mass or diameter.

Identiferoai:union.ndltd.org:bl.uk/oai:ethos.bl.uk:680418
Date January 2015
CreatorsSmith, Jessica Rose
ContributorsCzernuszka, Jan T. ; Jackson, David
PublisherUniversity of Oxford
Source SetsEthos UK
Detected LanguageEnglish
TypeElectronic Thesis or Dissertation
Sourcehttp://ora.ox.ac.uk/objects/uuid:dc1b83e1-c74a-4f28-b4a8-c7da671e3541

Page generated in 0.0023 seconds