Investigation of size, concentration and particle shapes in hydraulic systems using an in-line CMOS image matrix sensor

The theoretical and experimental investigation of the novel in-line CMOS image sensor was performed. This sensor is aimed to investigate particle size distribution, particle concentration and shape in hydraulic liquid in order to implement the proactive maintenance of hydraulic equipment. The existing instruments such as automatic particle counters and techniques are not sufficiently enough to address this task because of their restricted sensitivity, limit of concentration to be measured and they cannot determine particle shape. Other instruments cannot be used as inline sensors because they are not resistant to the arduous conditions such as high pressure and vibration. The novel mathematical model was proposed as it is not possible to use previously developed techniques based on using optical system and complicated algorithms. This model gives the output signal of the image sensor depending on the particle size, its distance from the light source (LED) and image sensor. Additionally, the model takes into account the limited exposure time and particle track simulation. The results of simulation based on the model are also performed in thesis. On the basis of the mathematical model the image processing algorithms were suggested in order to determine particle size even when this size is lower than pixel size. There are different approaches depending on the relation between the size of the particle and the pixel size. The approach to the volume of liquid sample estimation was suggested in order to address the problem of low accuracy of concentration measurement by the conventional automatic particle counters based on the single photodiode. Proposed technique makes corrections on the basis of particle velocity estimation. Approach to the accuracy estimation of the sensor was proposed and simulation results are shown. Generally, the accuracy of particle size and concentration measurement was considered. Ultimately, the experimental setup was used in order to test suggested techniques. The mathematical model was tested and the results showed sufficient correlation with the experiment. The zinc dust was used as a reference object as there are the particles within the range from 1 to 25 microns which is appropriate to check the sensitivity. The results of experiments using reference instrument showed the improved sensitivity and accuracy of volume measured compared to the reference one.

Identiferoai:union.ndltd.org:bl.uk/oai:ethos.bl.uk:768122
Date January 2018
CreatorsKornilin, Dmitriy V.
ContributorsMcMillan, Alison
PublisherUniversity of Chester
Source SetsEthos UK
Detected LanguageEnglish
TypeElectronic Thesis or Dissertation
Sourcehttp://hdl.handle.net/10034/621947

Page generated in 0.0018 seconds