Consequently, this study aims to develop novel technologies that can measure BP non invasively and continuously without a cuff. The proposed method estimates BP using features including pulse transit time (PTT), which is defined as the time interval from R wave of electrocardiogram to onset of photoplethysmogram within the same heart cycle. / Despite the importance of controlling blood pressure (BP) to our health, BP remains inadequately managed worldwide. Due to global ageing and change of human lifestyles, the number of hypertensives is anticipated to continue rising from approximately 1 billion in 2000 to 1.56 billion by 2025. A stumbling block to BP management is high BP usually develops without obvious symptoms. As a result, many people are unaware of their condition until severe problems such as a stroke, a heart attack or kidney failure have occurred. In China, over 100 million people do not know they have developed hypertension and are living under a potential risk to their health. In addition to high BP, variations of BP are also independent indicators of morbidity and mortality of severe diseases. Yet, sudden changes in BP are difficult to be detected by state-of-the-art BP meters, which operate on principles that require an inflatable cuff to give only a snapshot of BP. / Lastly, since the technology required information from several sensors that are placed on different body parts of a person, development of body area network (BAN) has been an important research focus. The concluding chapter of this thesis presents a new concept in this area, namely the hybrid body area network (h-BAN). In particular, the use of biological channels (bio-channels) for intra-BAN communication and securing wireless intra-BAN communication is discussed. / Nevertheless, a major challenge of this approach is its requirement of a calibration procedure. One possible solution is to calibrate against a cuff-based device, but this is inconvenient particularly when calibration has to be refreshed from time to time. Therefore, a bio-model is proposed and developed for PTT along an artery where the hydrostatic component of BP varies. The model can be applied to calibrate the cuffless PTT-based approach and estimate BP by simple movements such as hand elevation. Several experiments were conducted to validate the assumptions of this model and the results were found to be promising. / The proposed PTT-based technology was evaluated on 85 subjects (aged 57+/-29 yrs., including 39 hypertensives) whilst they were at rest in a sitting posture. A total of 999 pairs of systolic BP (SBP) and diastolic BP (DBP) estimations were made with reference to conventional cuff-based devices (i.e. a mercury sphygmomanometer and an oscillometric device) over a period of 6.4 weeks. The results of the study show that reference and estimated BP differed by 0.4+/-9.3 mmHg and 0.8+/-5.8 mmHg for SBP and DBP respectively (AAMI required mean and SD to be less than 5 and 8 mmHg correspondingly). / The results of both studies show that the accuracy of the PTT-based technique is comparable to the cuff-based approaches. This technique is potentially useful to measure BP continuously. / To conclude, this work developed a non-invasive and cuffless approach for BP measurement and addressed several key issues of this approach, i.e. the analysis, calibration, and implementation of it. The work can help to realise new BP management schemes in mobile health (m-Health) and personalised healthcare systems, which are developed to cater for the needs of the increasing aging population world-wide and to prevent and control chronic diseases like hypertension. / To further the investigation, a second study which was to investigate in a clinical setting for post-operation condition, was carried out on 8 patients (aged 55+/-18 yrs.) using the averaged invasive arterial-line and cuff readings taken at intervals of 40.0+/-24.7 min. as reference. After calibrating the new approach on each individual, it can estimate SBP and DBP within 3.3+/-6.5 mmHg and 4.3+/-6.4 mmHg of the reference for the complete set of 89 estimations. / Poon, Chung Yan Carmen. / "December 2007." / Adviser: Yuon-Ting Zhang. / Source: Dissertation Abstracts International, Volume: 69-08, Section: B, page: 4888. / Thesis (Ph.D.)--Chinese University of Hong Kong, 2007. / Includes bibliographical references (p. 91-103). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Electronic reproduction. [Ann Arbor, MI] : ProQuest Information and Learning, [200-] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstracts in English and Chinese. / School code: 1307.
Identifer | oai:union.ndltd.org:cuhk.edu.hk/oai:cuhk-dr:cuhk_344130 |
Date | January 2007 |
Contributors | Poon, Chung Yan Carmen., Chinese University of Hong Kong Graduate School. Division of Electronic Engineering. |
Source Sets | The Chinese University of Hong Kong |
Language | English, Chinese |
Detected Language | English |
Type | Text, theses |
Format | electronic resource, microform, microfiche, 1 online resource (xiii, 103 p. : ill.) |
Rights | Use of this resource is governed by the terms and conditions of the Creative Commons “Attribution-NonCommercial-NoDerivatives 4.0 International” License (http://creativecommons.org/licenses/by-nc-nd/4.0/) |
Page generated in 0.0027 seconds