Return to search

Investigations of the assessment of bioequivalence of topical clotrimazole products using a dermatopharmacokinetic approach

The specialised nature of the stratum corneum makes it an efficient barrier to foreign substances, including drug molecules. Therefore, cutaneous drug absorption is a slow and complex process of which stratum corneum penetration is the rate limiting step. The rate and extent of stratum corneum penetration by a drug compound depends greatly on the presence of penetration enhancing/retarding excipients and therefore the clinical outcomes of a product rely greatly on the components and quality of the formulation. Hence, establishing bioequivalence between topical products is crucial to ensure that patients receiving multisource drug products are assured of the same efficacy and safety as the brand product. Since locally acting topical formulations do not target the systemic circulation, conventional methods of assessing bioequivalence using plasma levels are not appropriate. Consequently, the current regulatory guidelines require comparative clinical trials to be carried out to show bioequivalence between topical products. As these studies are very expensive and time consuming, the development of a more direct and relatively rapid and inexpensive method for determining bioequivalence between topical products is required. Clotrimazole is an anti-fungal agent where the target site of action is in the stratum corneum. In this work, tape stripping, which involves the sampling of stratum corneum, was investigated as a tool for the determination of bioequivalence between topical clotrimazole products. The tape stripping method involved the analysis of each tape strip individually and standardization of stratum corneum thickness between subjects was carried out using TEWL measurements. This approach provided detailed information regarding the amount of clotrimazole present in the stratum corneum as well as the extent of drug penetration. Prior to the tape stripping studies an HPLC method was developed for the quantitative analysis of clotrimazole from the tape strip samples. This method was shown to be accurate and reproducible across the required range. It was also shown to be selective for clotrimazole in the presence of possible interfering substances such as those present in the tape adhesive and also skin components. The bioequivalence studies were conducted using a single “uptake” time point. In order to determine an appropriate dose duration for these studies a novel approach was employed, involving a preliminary dose duration study. For the bioequivalence investigations, Canesten® Topical cream was used as both test and reference products to determine if the method was capable of showing bioequivalence. Subsequently, Canesten® Topical cream was also compared to a 1% gel formulation to determine if the method could detect formulation differences. The conventional BE limits of 0.8 – 1.25 were used for the assessment of BE, however, the clinical relevance of using these limits for dermal studies is debatable since they are derived from oral pharmacokinetic studies. Therefore, the data from the tape stripping investigations were also assessed using more realistic limits of 0.75 – 1.33 and even 0.7 – 1.44. In addition to the tape stripping studies a novel method of determining the amount of drug present in the stratum corneum, the “Residual Method”, was investigated. This method involved assaying the amount of clotrimazole found in the residual formulation after a specified dose duration had elapsed and subtracting that amount from the amount of clotrimazole initially applied. The results of tape stripping investigations showed that, if the study is sufficiently powered, tape stripping may be used to determine bioequivalence according to the conventional limits, as well as possibly detect formulation differences between different clotrimazole products. Bioequivalence assessment using the widened intervals showed that fewer subjects were required to achieve a sufficient statistical power. The variability associated with this method was acceptable and tape stripping may therefore have the potential to be used as a BE tool in a regulatory setting for clotrimazole or other antifungal topical formulations. The “Residual Method” also showed promising results as a bioequivalence tool, but further investigation and extensive validation of this method is required before it can be suggested as a regulatory method. The results of these studies have clearly indicated that tape stripping has the potential to be used as an alternative to comparative clinical trails for the assessment of bioequivalence between clotrimazole formulations and also to assess bioequivalence between other antifungal products.

Identiferoai:union.ndltd.org:netd.ac.za/oai:union.ndltd.org:rhodes/vital:3840
Date05 July 2010
CreatorsParfitt, Natalie Rae
PublisherRhodes University, Faculty of Pharmacy, Pharmacy
Source SetsSouth African National ETD Portal
LanguageEnglish
Detected LanguageEnglish
TypeThesis, Masters, MSc
Format195 p., pdf
RightsParfitt, Natalie Rae

Page generated in 0.002 seconds