Approved for public release; distribution is unlimited. / The method of taking unsteady pressure measurements, on a research transonic compressor rig, was lost during the transition from the traditionally designed Vavra stage to the Sanger stage. The Sanger stage was designed using computational fluid dynamics (CFD) techniques. It required a new case wall in which the unsteady pressure sensors, due to outdated software and data acquisition system, were not initially installed. In the present study, unsteady pressure measurements were reestablished, with the installation of sensors and development of a new data acquisition and data reduction system. Data were taken at 60%, 70%, and 80% design speed. Data at 60% and 70% were compared to computational predictions and reasonable agreement was obtained. / Ensign, United States Navy

Identiferoai:union.ndltd.org:nps.edu/oai:calhoun.nps.edu:10945/920
Date06 1900
CreatorsRodgers, Matt W.
ContributorsShreeve, Raymond, Hobson, Garth, Naval Postgraduate School (U.S.), Aeronautical Engineering
PublisherMonterey, California. Naval Postgraduate School
Source SetsNaval Postgraduate School
Detected LanguageEnglish
TypeThesis
Formatxiv, 99 p. : ill. (some col.) ;, application/pdf
RightsThis publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. As such, it is in the public domain, and under the provisions of Title 17, United States Code, Section 105, may not be copyrighted.