Return to search

Delayed neutron emission measurements for U-235 and Pu-239

The delayed neutron emission rates of U-235 and Pu-239 samples were measured
accurately from a thermal fission reaction. A Monte Carlo calculation using the Geant4
code was used to demonstrate the neutron energy independence of the detector used in the
counting station.
A set of highly purified actinide samples (U-235 and Pu-239) was irradiated in these
experiments by using the Texas A&M University Nuclear Science Center Reactor. A fast
pneumatic transfer system, an integrated computer control system, and a
graphite-moderated counting system were constructed to perform all these experiments.
The calculated values for the five-group U-235 delayed neutron parameters and the
six-group Pu-239 delayed neutron parameters were compared with the values
recommended by Keepin et al. (1957) and Waldo et al. (1981). These new values differ
slightly from literature values. The graphite-moderated counting station and the
computerized pneumatic system are now operational for further delayed neutron
measurement.

Identiferoai:union.ndltd.org:tamu.edu/oai:repository.tamu.edu:1969.1/ETD-TAMU-1134
Date15 May 2009
CreatorsChen, Yong
ContributorsReece, W. Dan
Source SetsTexas A and M University
Languageen_US
Detected LanguageEnglish
Typethesis, text
Formatelectronic, application/pdf, born digital

Page generated in 0.0021 seconds