Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 26 for “""wall-Tube" electrode"”
-
Effects of rf power and tube wall temperature on plasma stability and analyte emission in furnace atomization plasma excitation spectrometry
… and does not depend absolutely on the furnace wall temperature but on the temperature of rf center electrode. The spatial distribution of analyte in the plasma shows an increase in emission intensity from the center of the furnace toward the wall, reaches a maximum at 1.25 mm from the center, …
-
Active surgical positioning device for a cochlear implant electrode array
… and effectively place an array of stimulating electrodes deep within the cochlea. This will lead to improved efficiency and performance of the stimulating electrodes, reduced surgical trauma to the cochlea, and as a result, improved overall performance to the implant recipient. The positioning …
-
Scanning probe microscopy and electrochemical studies of deposition on electrode surfaces
… electrochemical deposition processes on carbon electrodes, particularly those associated with diffusion-controlled multiple nucleation. Anodic stripping voltammetry for analytical measurements using solid electrodes is addressed in the light of limitations arising from electrode heterogeneity, …
-
Innovative Electrode Nanocomposites for Energy Storage and Conversion Systems
… emerged as suitable alternatives for electrode materials, are defined as “two or more materials with different properties remain separate and distinct on a macroscopic level within one unity and with any dimension in any phase less than 100 nm”. Recently, polymer/carbon based …
-
Improved performance of metal hydride electrode of Ni-MH battery with carbon nanotubes.
… and electronic applications. Carbon nanotubes (CNTs) have the largest hydrogen storage capacity among the hydrogen storage materials known at present. The Ni-MH battery can be used to store and then discharge large amounts of hydrogen reversibly by using hydrogen storage materials as …
-
Electrical Properties of a Tube-in-a-Tube Semiconductor
Tube-in-a-tube (Tube^2) nanostructures were synthesized through the outer-wall selective covalent functionalization of double-walled carbon nanotubes (DWCNTs) at high functional densities. Upon functionalization, the properties of individual walls within the structure decouple resulting in an …
-
Electrical power extraction from a supersonic plasma flow
… flow behind a free running shock in a shock tube and let the flow impinge onto a conical obstacle mounted in the middle of the tube to create a standing shock. This cone has a conducting surface which acts as the anode. The cathode is mounted flush with the shock tube wall at a position …
-
Generation of Large-Volume Diffuse Plasma by an External Ionization Wave From a Single-Electrode Plasma Jet
… FIW with a dielectric surface which forms the wall of the reduced-pressure system, and the formation and propagation of the reduce-pressure FIW inside a chamber. In this study, key characteristics of the transient diffuse plasma are discussed. The reduced pressure plasma parameters were …
-
Separation control in low pressure turbines using plasma actuators with passing wakes
… wakes were taken using a glass total-pressure tube. Corrections for streamline displacement due to shear and wall effects were made, and comparisons with previous hot-wire measurements were used to validate data. Performance features of conventional two-electrode and a novel three-electrode …
-
ENHANCEMENT OF CONVECTIVE HEAT TRANSFER IN INTERNAL FLOWS USING AN ELECTRICALLY-INDUCED CORONA JET
… the plasma region and move toward the grounded electrode. The accelerating ions collide with neutral particles of the surrounding gas and impose a dragging effect which is interpreted as a body-force to the air particles. The shape and configuration of the emitting and receiving electrodes has a …
-
Mechanisms of electrohydrodynamic (EHD) flow and heat transfer in horizontal convective boiling channels
… systems. The experimental study involved tube-side boiling heat transfer of the environmentally friendly HFC-134a in a single-pass, counter-flow heat exchanger 1.5 m in length, 12.7 mm O.D., 10.92 mm I.D., with a 3.18 mm rod electrode. The electrode position was varied from a concentric …
-
Electrical power generation from standing shock waves
… which an electrical potential is established. If electrodes are mounted upstream and downstream of the standing shock, an electrical current can be extracted. The electrical power output by such a system (called a bow shock generator) has been measured. To produce the supersonic flow an overdriven …
-
Driving microfluidic flows with three dimensional electrodes.
… strategies of 3D structures used as pumping electrodes for micro fluidic applications. 3D electrodes drive flows over the whole channel height while 2D electrodes stay near one wall. The first application of the 3D electrodes is mixing chemical or biological samples with reagents for chemical …
-
Further Development of Atmospheric Pressure, Self-Igniting Microplasma Devices (MPDs) for Elemental Analysis of Liquid Microsamples Using Atomic Emission Spectrometry (AES)
… by confining the microplasma to a quartz tube (“wall-stabilized”) in hopes of a more stable MPD background emission. Once stabilized MPD conditions were found key microplasma parameters were studied including MPD power, HVac frequency, operating mode, inter-electrode distance (IED) and …
-
Development of a Standing Wave Tube Rotary Ultrasonic Piezoelectric Motor for LiDAR Systems
… source, and a bulk piezoelectric actuator of a tube form. The excitation wave type and the actuator shape are the only two fixed parameters in this study. The other parameters investigated in this thesis are electrode configuration parameters, such as the number of electrodes, active electrode …
-
Development and characterization of an electrothermal vaporization parallel plate capacitively coupled plasma
… is initiated and sustained in a quartz discharge tube placed between a pair of water-cooled conducting electrodes to which rf power is applied. The geometry of the discharge torch is flexible and allows the introduction of both liquid (using electrothermal vaporizer, ETV) and gaseous samples into …
-
MECHANISMS OF ELECTROHYDRODYNAMIC TWO-PHASE FLOW STRUCTURES AND THE INFLUENCE ON HEAT TRANSFER AND PRESSURE DROP
… was investigated inside a smooth horizontal tube with a concentric rod electrode used to apply high voltage to a flow of refrigerant R-134a.</p> <p>The EHD flow structures were initially observed to be a transient phenomenon that appeared during the initial step input of high voltage and were …
-
Interaction Between Carbon Nanotubes and Metals (Al, Cu) and the Effects on Resultant Properties of the Hybrid Materials
… electrical and thermal properties, carbon nanotubes (CNTs) have been regarded as promising candidates for advanced nanoelectronics and multifunctional nanocomposites. In this dissertation, the interaction of CNTs with metals have been investigated and the resultant electrical conduction have …
-
Radio-frequency generation of an electron plasma in a Malmberg-Penning trap and its interaction with a stationary or pulsed electron beam.
… and detected by means of a photomultiplier tube. The minimum sensitivity of the backscattering diagnostics has been estimated for the present set-up configuration. Constraints on the number of photons and thus on the information one can obtain with the Thomson backscattering technique are …
-
Coupling Ambient Ionization Mass Spectrometry with Liquid Chromatography and Electrochemistry and Their Applications
… A new splitting interface, a PEEK capillary tube with a micro-orifice drilled in the capillary wall, was used to connect with LC column for applying DESI ionization. A small portion of LC eluent emerging from the orifice can be directly ionized by DESI with negligible time delay while the …
Page 1 of 2