Multivariate analysis methods for veterinary diagnostics using SIFT-MS
Selected ion flow tube mass spectroscopy (SIFT-MS) is an analytical method for the investigation of volatile organic compounds (VOCs). It produces mass to charge (m/z) ratio ion counts with a range of 10-200 m/z. Current data analysis involves sifting through the spectra files one at a time looking …
-
Investigation Of Corrosion In Canned Chicken Noodle Soup Using Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS)
… soups, Selected Ion Flow Tube–Mass Spectrometer (SIFT-MS) was used. The coatings of the tested cans were carefully stripped off and analyzed using SIFT-MS method also. Scanning Electron Microscopy (SEM) was used to detect the appearance of breaches in the lacquer of the tested cans, and Energy …
-
The Characterisation and Development of a Passivated Inlet to Selected Ion Flow Tube Mass Spectrometry (SIFT-MS)
SIFT-MS is a relatively new trace gas analysis technique that has wide application. One particular attribute of the instrument is the ability to detect and quantify volatile organic compounds to the parts per trillion in real-time without the need for sample preparation. However the issue of …
-
Volatile generation in bell peppers during frozen storage and thawing using selected ion flow tube mass spectrometry (SIFT-MS)
… by a Selected Ion Flow Tube Mass Spectrometer (SIFT-MS). Lipoxygenase (LOX) activity was determined by UV-Visible Spectrophotometry. As a direct effect of blanching, (Z)-3-hexenal had a large significant decrease in concentration since it is a heat labile compound while most other volatiles did …
-
Analysis of factors affecting volatile compound formation in roasted pumpkin seeds with selected ion flow tube mass spectrometry (SIFT-MS)
… by a Selected Ion Flow Tube Mass Spectrometer (SIFT-MS). Volatiles dominating in raw pumpkin seeds were lipid aldehydes, ethyl acetate, 2, 3-butandione and dimethylsulfide. Compounds contributing to roasted aroma include alkylpyrazines, and Strecker and lipid aldehydes. Overall, hull-less seeds …
-
Evaluation of Flavor Variation in Swiss Cheese from Five Factories Using Selected Ion Flow Tube Mass Spectrometry (SIFT-MS), Descriptive Sensory Analysis, and Consumer Testing
… using selected ion flow tube-mass spectrometry (SIFT-MS), descriptive sensory analysis, and consumer sensory testing. Three Swiss cheese samples were obtained from each of five different factories for a total of fifteen samples. These cheeses varied in manufacturing dates, as well as the vat and …
-
Etude de sesquiterpénoïdes d'intérêt chez la vigne : analyse par SIFT-MS et impact de facteurs génotypiques et abiotiques sur la biosynthèse et l'accumulation de la rotundone
… Premièrement, une technologie récente, le SIFT-MS, a été mise en œuvre et a permis de discriminer différents cépages sur la base de leur production volatile, leurs caractéristiques aromatiques et liens de parenté connus. Les constantes réactionnelles et les rapports d’embranchement des …
-
Application of Selected-Ion-Flow-Tube Mass Spectrometry For Real-Time Operando Quantitative Measurement of Product Formation for Electrochemical Reduction of Carbon Dioxide
… use of selected-ion flow-tube mass spectrometry (SIFT-MS) that quantitatively measures in realtime an array of 10 C1, C2, and C3 products from CO2R such as ethanol, ethylene or methane. The custom-developed SIFT-MS selected ion mode scan measures the concentration of gas and liquid-phase products …
-
A FUNDAMENTAL AND APPLIED APPROACH TO SELECTED ION FLOW TUBE-MASS SPECTROMETRIC STUDY OF VOLATILE ORGANIC COMPOUNDS IN SWISS-TYPE CHEESES
… using selected ion flow tube-mass spectrometry (SIFT-MS) has been proven to be rapid and efficient. The determination and discrimination of VOC profiles from each eye, blind and split areas within a cheese from a given factory was successfully made. VOC profile inhomogeneity was evident in …
-
Rapid Quality Assessment of Corn-Based products by Infrared Spectroscopy and Selected Ion Flow Tube Mass Spectroscopy with Multivariate Analysis
… and selected ion flow tube mass spectroscopy (SIFT-MS) for assessing the development of off-flavors in corn-based snacks and identifying the components contributing to the undesirable aroma. A local manufacturer of grain-based snacks provided test samples that developed off-flavors and their …
-
Flavour Analysis of Green Tea Enriched Cookies using Sensory and Instrumental Techniques
… from selected ion flow tube mass spectrometry (SIFT-MS) and sensory properties of the cookies. Five volatiles that had a significant impact on the flavour of the samples were found. Flavour perception is a dynamic process because volatiles change as the product is chewed. Sensory properties and …
-
Empreinte volatile des produits agroalimentaires : un nouvel outil pour tracer l'authenticité et suivre des procédés
… un spectromètre de masse à injection directe (SIFT-MS Selected Ion Flow Tube Mass Spectrometer) a été choisi pour ses performances : sa rapidité d’analyse, sa capacité de détection et sa sensibilité. Une nouvelle exploitation d’analyse non ciblée des COV a été mise en place sur deux matrices : …
-
Contribution of enzymes and other components in food in the formation and destruction of volatile compounds.
… puree made with peel was less preferred in terms of flavor, aroma and overall liking than those made without peel. Deodorization of undesirable garlic breath was achieved by consumption of water (control), raw, juiced or heated apple, raw or heated lettuce, raw or juiced mint leaves or green …
-
Controlling the Production of Off-odor Guaiacol by Alicyclobacillus acidoterrestris in Apple juice or a Microbiological Medium
… Selected Ion Flow Tube Mass Spectrometery (SIFT-MS). Incubated samples were held at 20-45 degree centigrade and pH 2.7-6.7 with 10mg/L vanillin. Minimum inhibitory concentrations (MICs) of polylysine and lauric arginate were determined at 37 degree centigrade and pH 3.7. Guaiacol …
-
Consumer products as a source of volatile organic compound emissions
… or government product regulations. This thesis aims to address this by three distinct analyses on consumer products using on-line mass-spectrometry, accompanied by a detailed global literature assessment, structured as four published journal papers. Selected-Ion Flow-Tube Mass Spectrometry …
-
Volatile Profile of Cashews (Anacardium occidentale L.), Almonds, and Honeys from Different Origins by Selected Ion Flow Tube Mass Spectrometry
… by Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS). Raw cashews were oil roasted for 3 to 9 min at 143 ¿¿¿¿C and color and volatiles measured. An excellent correlation, following a pseudo-first order reaction, was found between L value and roasting time; darkness increases as roasting time …
-
AB-INITIO CALCULATION OF THE RATES OF THE REACTIONS BETWEEN VOLATILE ORGANIC COMPOUNDS IN WINE AND CATIONS FOR MASS SPECTROMETRY
… proton transfer reaction mass spectrometry (PTR-MS) and selected ion flow tube mass spectrometry (SIFT-MS), are being successfully employed in the measurements of VOCs concentrations. Quantification using these techniques usually relies on compound-by-compound instrument calibration. The …
-
Étude et développement d'un procédé de traitement des odeurs par oxydation à l'ozone : application aux effluents gazeux d'usines de production de superphosphate
… butanal). Deux techniques analytiques (GC/FID et SIFT/MS) ont été mises en œuvre afin d’évaluer les performances d’élimination de ces composés, la difficulté d'analyser une matrice gazeuse contenant de l'ozone ayant été mise en évidence. Ainsi, une interférence de l'ozone sur l'analyse des …
-
The Effect of Milk on the Deodorization of Malodorous Breath after Garlic Ingestion
… a selected ion flow tube-mass spectrometry (SIFT-MS). Fat-free and whole milk significantly reduced the head-, mouth-, and nose-space concentrations of all volatiles. Water was the major component in milk responsible for the deodorization of volatiles. Due to its higher fat content, whole …
-
VOLATILE ORGANIC COMPOUNDS ANALYSIS AND METABOLOMICS FOR EARLY DETECTION OF LUNG CANCER
… in-vitro approaches. Two clinical studies using SIFT-MS and GC/MS were conducted. Several key confounders to breath analysis were identified. A combination of 8 VOCs achieved diagnostic sensitivity and specificity of 85% and 76% respectively, they could be used as potential biomarkers for lung …