Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 16 of 16 for “"µPIV"”

  1. High Resolution Measurements near a Moving Contact Line using µPIV

    … micron-resolution Particle Image Velocimetry (µPIV). Capillary numbers range from 1.7 x 10^(⁻⁴) to 6.2 x 10^(⁻⁴). Interface velocities were measured between 1.7 µm/s and 33 µm/s. Dynamic contact angles were manually measured between 1.1 µm and 120 µm from the contact line, and calculated from …

    portland-state Repository record for High Resolution Measurements near a Moving Contact Line using µPIV (opens in a new tab)

  2. Rheological and Velocity Profile Measurements of Blood in Microflow Using Micro-particle Image Velocimetry

    … technique of micro-particle image velocimetry (µPIV) was investigated to measure the velocity profiles of blood microflows. The material of the channel, the type of tracer particles, the camera used, and the choice in data processing were all validated to improve the overall accuracy of µPIV as …

    ottawa-retro Repository record for Rheological and Velocity Profile Measurements of Blood in Microflow Using Micro-particle Image Velocimetry (opens in a new tab)

  3. De la formation de gouttelettes à l'émulsification : approche expérimentale à micro-échelle

    … et la microvélocimétrie par image de particules (µPIV). La taille des gouttelettes principales et satellites formées en jonction flow-focusing est déterminée pour des fluides newtoniens et non-newtoniens. Les mêmes paramètres critiques sont mis en évidence pour ces jonctions flow-focusing et des …

    star-france Repository record for De la formation de gouttelettes à l'émulsification : approche expérimentale à micro-échelle (opens in a new tab)

  4. Analysis of blood flow during vascular development in chick embryos

    … using micro particle image velocimetry (µPIV) at different somite stages during the development of the chick embryo. We measured the viscosity of avian embryonic blood for the first time ever, using a micro viscometer and calculated the change inshear stress during vascular remodelling. …

    mcgill Repository record for Analysis of blood flow during vascular development in chick embryos (opens in a new tab)

  5. Investigations into inkjet cell printing hydrodynamics through microscopy imaging techniques

    … a nozzle can influence the cell's behavior, µPIV was performed to identify the flow field evolution during droplet ejection. Through the study of cell motion, it was observed that the viscosity of the media in the cell suspension plays an important role in influencing the cell behavior. This …

    ubc Repository record for Investigations into inkjet cell printing hydrodynamics through microscopy imaging techniques (opens in a new tab)

  6. Harnessing fluorescent nano-material to visualize microfluidics

    … demanded for micro particle image velocimetry (µPIV). To elevate the speed, current solutions dominantly focus on the illumination sources---more powerful lasers. Yet, the achievable speed is still insufficient to capture fast and complex flow fields. Hence, we have conceptualized and proposed …

    nanyang Repository record for Harnessing fluorescent nano-material to visualize microfluidics (opens in a new tab)

  7. Light Field Imaging Applied to Reacting and Microscopic Flows

    … the 3D PIV prone to error. Microscopic PIV (µPIV) was performed on a channel containing a backward facing step. A microlens array was placed in the imaging section of the setup to capture a light field from the scene, which was then refocusing using SA refocusing. PIV on these volumes was …

    byu Repository record for Light Field Imaging Applied to Reacting and Microscopic Flows (opens in a new tab)

  8. A fundamental examination of acoustic streaming in porous media multiphase flow

    … via microscopic particle image velocimetry (µPIV). The research begins with a detailed investigation of water-oil displacement in pillar-based microstructures, revealing how porosity and flow rate affect interfacial dynamics and displacement efficiency. Subsequent chapters focus on the …

    iastate Repository record for A fundamental examination of acoustic streaming in porous media multiphase flow (opens in a new tab)

  9. Separation, Flow Characterisation, and Optogenetic Control of Motile Bacteria

    … including Micro-Particle Image Velocimetry (µPIV) and Particle Tracking Velocimetry, to explore the flow fields generated by rotating bacterial cells. The findings reveal that rod-shaped bacterial cells can generate distinct micro-vortices with circular flow fields, their dynamics contingent …

    unsw Repository record for Separation, Flow Characterisation, and Optogenetic Control of Motile Bacteria (opens in a new tab)

  10. Study of the effects of spherical aberration and signal levels on a diffraction-based multiplane microscope and its application to evaluate the fluid shear stress around a cell

    … to perform micro-particle image velocimetry (µPIV), a technique able to reconstruct the velocity and shear stress fields imposed by a liquid flowing around a cell. The system has been, first, tested in absence of cells, achieving, within 10 µm from the coverslip glass, an accuracy on the …

    heriot-watt Repository record for Study of the effects of spherical aberration and signal levels on a diffraction-based multiplane microscope and its application to evaluate the fluid shear stress around a cell (opens in a new tab)

  11. Surfactant effects on drop formation and flow characteristics in liquid-liquid microfluidic systems

    … high-speed micro-Particle Image Velocimetry (µPIV) system was developed to follow the rapid formation of drops in the microchannels and obtain velocity fields during each stage. The experimental results demonstrated the strong influence of the surfactant on drop size, drop formation time, …

    ucl Repository record for Surfactant effects on drop formation and flow characteristics in liquid-liquid microfluidic systems (opens in a new tab)

  12. Formation and flow of droplets in complex fluids in microfluidic channels

    … an innovative micro-Particle Image Velocimetry (µPIV) technique was developed as part of this project. In this technique, two laser wavelengths illuminated two different particle types, each seeded in one of the phases of the two-phase mixture, in order to capture the shape of the interface and …

    ucl Repository record for Formation and flow of droplets in complex fluids in microfluidic channels (opens in a new tab)

  13. Effects of Short Exposure to High Shear on Neutrophil State and Function

    … using a microparticle image velocimetry (µPIV) setup. This setup tracks the positions of small fluorescent particles (1 µm) moving with the fluid, and allows us to characterize the fluid velocity in the channels. Wall shear rates and exposure times were subsequently estimated from these …

    oklahoma-thes Repository record for Effects of Short Exposure to High Shear on Neutrophil State and Function (opens in a new tab) Restricted access

  14. In Vitro Investigation of Cell-Free Layer Formation in Microchannels: Dependency on the Red Blood Cell Aggregation and Field of Shear

    Red blood cells (RBCs) form approximately 40 to 45% of the human blood volume, and their behaviour and characteristics are the main determinant of blood properties, such as viscosity. RBCs are deformable species and stack together under low shear rate to form aggregates or rouleaux. Flowing RBCs …

    ottawa-retro Repository record for In Vitro Investigation of Cell-Free Layer Formation in Microchannels: Dependency on the Red Blood Cell Aggregation and Field of Shear (opens in a new tab)

  15. Beitrag zur Optimierung von Reinigungsprozessen im nicht immergierten System unter Anwendung gravitationsgetriebener Flüssigkeitsfilme

    Die Herstellung hochqualitativer Produkte in der Lebensmittel-, Kosmetik- und Pharmaindustrie erfordert den Einsatz reproduzierbarer Reinigungsprozesse. Häufig wird die nasschemische Reinigung als Cleaning in Place Verfahren angewandt. Diese Arbeit leistet einen Beitrag zur Optimierung von …

    qucosa-diss Repository record for Beitrag zur Optimierung von Reinigungsprozessen im nicht immergierten System unter Anwendung gravitationsgetriebener Flüssigkeitsfilme (opens in a new tab)