Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"µPads"”.

  1. Miniaturization of features in microfluidic paper-based analytical devices for user-friendly testing and diagnosis using small sample volumes

    Microfluidic paper-based analytical devices (µPADs) are a promising platform for analytical testing, particularly for medical diagnosis. One of the main advantages of µPADs is the capacity for inexpensive, portable and user-friendly diagnostic devices for people who do not have access to …

    uoit Repository record for Miniaturization of features in microfluidic paper-based analytical devices for user-friendly testing and diagnosis using small sample volumes (opens in a new tab)

  2. Pump-free magnetophoresis for improved point-of-care diagnostics

    … Microfluidic paper-based analytical devices (µPADs) are a popular alternative to traditional microfluidics due to the natural capillary action through cellulose fibers and simple fabrication. µPADs are portable, low-cost, and do not require external instrumentation, making them ideal for POC …

    colostate Repository record for Pump-free magnetophoresis for improved point-of-care diagnostics (opens in a new tab)

  3. Active transport and concentration of analytes in microfluidic paper based analytical devices using ion concentration polarization

    Microfluidic paper-based analytical devices (µPADs) have a high potential for miniaturizing complex testing functions, since they are inexpensive, disposable, and portable. Paper has the advantage over traditional fluid channel systems in that it houses capillary-driven flow, which requires no …

    uoit Repository record for Active transport and concentration of analytes in microfluidic paper based analytical devices using ion concentration polarization (opens in a new tab)

  4. Development of Portable and Easy-to-Use Chemo/Biosensors

    … Microfluidic paper-based analytical devices (µPADs) and tablet-based assays represent promising platforms for developing such detection tools, particularly for resource-limited settings. However, challenges and gaps remain. Improvements in µPAD fabrication are needed to enhance accessibility, …

    concordia Download PDF for Development of Portable and Easy-to-Use Chemo/Biosensors (opens in a new tab)

  5. Developing paper-based devices for mapping agricultural pesticides and environmental contaminants

    … microfluidic paper-based analytical devices (µPADs) are becoming more common as inexpensive, fast, easy to use devices to detect and quantify a variety of analytes. My research has been focused on developing µPADs for three different analytes: pesticides, PFAS, and heavy metals. In order to …

    colostate Repository record for Developing paper-based devices for mapping agricultural pesticides and environmental contaminants (opens in a new tab)

  6. Laser-based direct-write technique for enabling newer functionalities in paper-based devices

    … development of paper-based microfuidic devices (µPADs). Despite the progress in the field of µPADs, there are still some important requirements yet to be addressed to improve their performance and enable their widespread use as a commercial product. In this thesis, we focus on the use of a …

    soton Download PDF for Laser-based direct-write technique for enabling newer functionalities in paper-based devices (opens in a new tab)

  7. Functional 3-D Cellulose & Nitrocellulose Paper-Based, Multiplex Diagnostic Platforms Without Coupling Agents

    … of 3-D paper-based, multiplex platforms, µPADs, without the use of coupling agents between layers. Previously, these platforms were fabricated with double-sided tape and cellulose powder to try to augment proper fluid routing, but difficulties with this method occurred. An acrylic housing …

    calpoly Repository record for Functional 3-D Cellulose & Nitrocellulose Paper-Based, Multiplex Diagnostic Platforms Without Coupling Agents (opens in a new tab)

  8. RAPID-PROTOTYPING OF PDMS-BASED MICROFLUIDIC DEVICES

    … paper-based analytical microfluidic devices (µPADs) as the testbed. When microfluidic devices are not rationally designed, and when the influence of fluidic resistance is not taken into account, sample dispersion can be biased. A bias can influence the output of colorimetric enzymatic assays …

    gatech Repository record for RAPID-PROTOTYPING OF PDMS-BASED MICROFLUIDIC DEVICES (opens in a new tab)

  9. Dispositivos microfluídicos à base de papel para determinação cobre em cachaça

    … dispositivos microfluíficos à base de papel (µPADs), almejando dois propósitos: i) propor um método que possibilite identificar, por meio de um sistema point of care, de modo simples e rápido, a presença da contaminação de Cu 2+ em cachaça nos próprios alambiques onde são fabricadas, e, por …

    brazil-ufv Repository record for Dispositivos microfluídicos à base de papel para determinação cobre em cachaça (opens in a new tab)

  10. Microfluidics for environmental analysis

    … distance-based analytical quantification in µPADs with optode nanosensors. Experimental results were obtained using the naked eye without the requirement of a power source or external hardware. The resulting distance-based µPAD showed high selectivity and the capacity to quantify K+ in real …

    colostate Repository record for Microfluidics for environmental analysis (opens in a new tab)

  11. Paper-Based Sensors for Contaminant Detection Using Surface Enhanced Raman Spectroscopy

    Surface enhanced Raman spectroscopy (SERS) is highly promising analytical technique for trace detection of analytes. It is particularly well suited for environmental analyses due to its high sensitivity, specificity, ease of operation and rapidity. The detection and characterization of …

    vt Repository record for Paper-Based Sensors for Contaminant Detection Using Surface Enhanced Raman Spectroscopy (opens in a new tab)