Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 63 for “"100 kV"”.
-
Návrh měřicího a záznamového systému pro 100 kV AC/DC KIT
… návrhem měřicího a záznamového systému pro 100 kV stavebnice KIT. Významná část práce se věnuje seznámení se stavebnici Haefely KIT 100kV, analýze principu činnosti měřicí jednotky DMI 551 a návrhu měřicího systému. Práce se dále věnuje výpočtu harmonického zkreslení, zvlněni, vrcholové, …
-
Operational radiation safety considerations during superficial x-ray treatment for veterinary applications
… radiation treatment (SRT) using the SRT-100™ result in a significant occupational dose to veterinary personnel present in the room during treatment. Measurements were taken for 50, 70, and 100 kV x-ray for 9 different SRT-100 applicators. The exposure rates at the surface of solid water …
-
Optimizing the Energy Transfer of Pulse Transformers
… load to a differential voltage of up to 100 kV. The first pulse charger was designed and tested to charge a 0.5 nF load to +/- 50 kV in less than 10 μs. This pulse charger was also designed to be modular, so multiple loads could be charged simultaneously. Changes to the pulse transformer …
-
How low can we go? CT dose reduction in the assessment of the medial clavicular epiphysis in forensic age estimation : a prospective postmortem CT study
… radiation dose was obtained using a CDMP with 100 kV and 40 mAs and an FPP with 100 kV and 30 mAs. Doses for 120 kV were significantly higher (one-tailed P < 0.001). The diagnostic image quality for 80 kV was insufficient overall. Discussion: Our results confirm that CT imaging at 100 kV allows …
-
Kilo-Voltage X-Ray Correction Factors for In-Water Measurements Based on TG-61
For x-ray tube potentials 100 kV, the AAPM TG-61 protocol for 40-300 kV x-ray beam dosimetry in radiotherapy recommends an in-water measurement which is based on ionization chambers calibrated in air in terms of air kerma. The variation of the overall correction factor (PQ;cham) and its components …
-
Temporal Calcium Response of Jurkat Cells to Nanosecond Pulsed Electric Fields
… 60 ns duration and field strengths from 25 tol00 kV/cm. The development of the induced calcium response in individual cells was studied by spinning-disc confocal microscopy with the calcium indicator Fluo-4. The fast imaging rate of this system allowed us to record the development of fluorescence …
-
Improved lens systems for the electron microscope
… for operation at an accelerating voltage of 1000 KV or more, but comparable in size to that of a 100 KV transmission electron microscope (TEM). An AE] EM6 100 KV TEM was modified for the purpose. In particular the standard viewing chamber was considerably shortened and all the original …
-
Niedrigdosis-Computertomographie des oberen Sprunggelenkes und der Fußwurzel - eine ex-vivo Studie
… 1,5 und 0,9, für die Röhrenspannung zwischen 120 kV und 100 kV und für das Röhrenstrom-Zeit-Produkt zwischen 100 mAs, 70 mAs und 40 mAs systematisch variiert. Aus den Rohdatensätzen wurden je 6 Bildansichten (3 axiale Schichten, 1 sagittale, 1 koronare, 1 para-koronare Schicht) nach vorgegebenen …
-
A high voltage piezoelectric transformer for active interrogation
… The goal of this project was to produce 100 kV with a reasonably sized piezoelectric crystal. Several mechanisms leading to less than expected high voltage have been addressed. This project addresses problems associated with high power, high stress, high voltage, mechanical loss, and high …
-
Electromagnetic pulse technology : biological and terahertz applications
… reflector and has two foci. A fast (< = 100 ps), high-voltage (> 100 kV) pulse launched from the first focal point is focused into a target located at the second focal point (near-field). It has been found that these pulses are useful for a variety of biological applications, such as …
-
Laboratory investigation of electrical dissipation of warm fog
… the center of the chamber was operated from 0 to 100 kV and measurements of fog conditions were made optically and with coated slides placed at various positions in the chamber. Rapid clearing was caused by the corona discharge. The dominant clearing mechanisms identified were coalescence and …
-
Application of Nanomaterials for X-ray Shielding and Dosimetry in Diagnostic Radiology
… using diagnostic X-ray energies from 40 to 150 kV. The results showed that the PDMS/BO nanocomposite (44.44 wt% of BO and 3.73 mm thick) was capable of attenuating all the scattered X-rays generated at a tube potential of 60 kV. Another aspect of my thesis-work involves X-ray detection using …
-
Design and construction of a high efficiency retarding potential Mott polarization analyzer
… have been bulky and required very high voltages (100 kV or more) in order to operate. In recent years more portable models which operate in the 20 kV range have been constructed with efficiencies (figures of merit) of $3\times 10\sp{-5}$. A very compact UHV compatible retarding potential Mott …
-
Investigation of Flow Phenomena in a Repetitively-Pulsed Gas Flow Switch
… static pressure of 98 kPa. A high voltage of 100 kV is applied between the electrodes resulting in a current of 20 kA. The results obtained are qualitatively consistent with properties measured experimentally for a similar discharge.
-
Advancing high power microwave spark-gap technology : design and analysis of a coaxial ringdown oscillator
… can only withstand breakdown voltages up to 100 kV, which limit peak output voltages, and a suboptimal Q-factor (Q) values, which reduces the amount of energy coupled to a target at a specific frequency. Therefore, the aim of this thesis is to design, fabricate, test, and evaluate a novel CRO …
-
Plasma source ion implantation of high voltage electrodes
… A series of high, negative voltages (30--100 kV) is applied to the workpiece to accelerate the ions in the plasma, implanting them to depths of several hundred Angstroms. to characterize the response of the modified electrodes to high field gradients, fields as high as 20 MV/m are applied …
-
Investigation and optimization of a high voltage piezoelectric particle accelerator
… fusion reaction, for instance, requires at least 100 kV for a reasonable cross-section, which is achievable using the piezoelectric transformer. While further development will be required to demonstrate neutron production using a piezoelectric transformer, the results showed that the piezoelectric …
Page 1 of 4