Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 26 for “"111.1"”
-
Využití izokinetického dynamometru pro měření a hodnocení svalové síly dolních končetin u sportovců
… porovnán mezi profesionálními sportovci (muži: 111.1 ± 51.0 [Nm/kg], ženy: 99.6 ± 90.8 [Nm/kg]) a amatérskými sportovci (muži: 146.2 ± 40.1 [Nm/kg], ženy: 45.3 ± 14.6 [Nm/kg]). Vztah byl pozorován mezi parametry úhlové pozice maxima a dobou od dosažení maxima do konce pohybu (flexe: = 0.65, …
-
Performance Characterization of Ceramic Matrix Composites through Uniaxial Monotonic Tensile Testing
… CMC samples produced a mean tensile strength of 111.1 megapascals (MPa) and an elastic modulus of 912.8 MPa. The A-basis for strength was 77.54 MPa and the B-basis was 95.37 MPa.
-
Experimental and Numerical Modeling of Heat Transfer in Wall Assemblies
… of Canada. Test specimens had a surface area of 111.1 mm (4.375 in.) by 111.1 mm (4.375 in.), and consisted of single or double layers of gypsum board, stone wool insulation and spruce-pine-fir (SPR) studs. As the specimens were designed to represent a one-quarter scale model of a common wall …
-
Implementación de la recuperación activa inmediata, a las 12 y 24 horas post-esfuerzo en jugadores juveniles de fútbol
… de la aplicación del SAFT 90 (mediana 103.1-111.1). La CK medida después de 48 horas refleja una recuperación en todos los grupos, sin embargo el grupo C muestra un decline en los niveles de CK en comparación con la línea de base (-55.5 (-96.3 / -20.4)) lo cual es un hallazgo significativo. …
-
Makroekonominių rodiklių įtaka Anglijos būsto kainoms /
… London and England excluding London increased by 111.1%, 248.4% and 101% respectively. Therefore, it would be advisable to reduce house prices by using previously mentioned macroeconomic factors. Reducing house prices would help to: reduce wealth inequality, reduce the risk of a house price bubble …
-
Catalytically Upgrading Short Chain Oxygenates Through Experimental and Modeling Techniques
… in water resulted in an activation energy of 111.1 p/m17.0 kJ /mol and an activation entropy of 13.8 p/m 37.2 J/K, while this dehydration reaction in toluene yields an activation energy of 133.9 p/m 7.7 kJ /mol and an activation entropy of 120.9 p/m 23.9 J/K. This work suggests that nonpolar …
-
Catalytically Upgrading Short Chain Oxygenates Through Experimental and Modeling Techniques
… in water resulted in an activation energy of 111.1 p/m17.0 kJ /mol and an activation entropy of 13.8 p/m 37.2 J/K, while this dehydration reaction in toluene yields an activation energy of 133.9 p/m 7.7 kJ /mol and an activation entropy of 120.9 p/m 23.9 J/K. This work suggests that nonpolar …
-
Catalytically Upgrading Short Chain Oxygenates Through Experimental and Modeling Techniques
… in water resulted in an activation energy of 111.1 p/m17.0 kJ /mol and an activation entropy of 13.8 p/m 37.2 J/K, while this dehydration reaction in toluene yields an activation energy of 133.9 p/m 7.7 kJ /mol and an activation entropy of 120.9 p/m 23.9 J/K. This work suggests that nonpolar …
-
Catalytically Upgrading Short Chain Oxygenates Through Experimental and Modeling Techniques
… in water resulted in an activation energy of 111.1 p/m17.0 kJ /mol and an activation entropy of 13.8 p/m 37.2 J/K, while this dehydration reaction in toluene yields an activation energy of 133.9 p/m 7.7 kJ /mol and an activation entropy of 120.9 p/m 23.9 J/K. This work suggests that nonpolar …
-
Ο ρόλος της υπερηχογραφικής μελέτης της νεφρικής λειτουργίας στην πρόγνωση της νεφρικής βλάβης στους βαρέως πάσχοντες ασθενείς
… AKI prediction (for RRI>0.7, OR 17.7; 95%CI: 2.8-111.1, p=0.002). Thearea under the receiver-operating characteristic (AUC ROC) curve for AKI prediction by RRIwas 0.936.RRI was significantly correlated with both P(cv-a)CO2/C(a-cv)O2 ratio and arteriallactate, r=0.64, p<0.0001 in both cases. The …
-
Synthesis and characterisation of silica adsorption platforms for use in environmental remediation
… capacity calculated using Langmuir isotherms of 111.1 mg g-1 was achieved, which was higher than previously reported for competitive sorbents. Moreover, adsorbents containing silica nanoparticles with different porosity parameters were synthesized and evaluated for Cr (VI) uptake. The adsorption …
-
Fly ash-based geopolymer as innovative material for environmental applications
… geopolymer with a maximum adsorption capacity of 111.1 mg/g. The magnetic fly ash geopolymer has a saturation magnetization of 18 emu/g and was found to separate out from an aqueous solution within 2 minutes by using a magnetic field of 0.48 Tesla. Applications of the magnetic fly ash geopolymer …
-
Efeito agudo do exercício intervalado de alta intensidade de baixo volume sobre a pressão arterial ambulatorial de normotensos
… (23.6 ± 3.6 years, 23.5 ± 2.3 kg/m2, resting PA 111.1 ± 6.4 / 62.4 ± 6.1 mmHg) performed: (i) maximum incremental test; (ii) HIIE and control sessions in a randomized order. The HIIE consisted of 10x60s at 100% of maximal velocity interspersed by 60s of passive recovery. The paired sample t-test …
-
Σύγκριση της πρασουγρέλης σε σχέση με την διπλή δόση κλοπιδογρέλης σε ασθενείς που έχουν υποβληθεί σε αγγειοπλαστική και παρουσιάζουν αντίσταση στη συνήθη δόση κλοπιδογρέλης, όπως αυτή προσδιορίζεται με την χρήση του μετρητή VerifyNow
… estimates 129.4, 95% confidence interval [CI]: 111.1 to 147.7 versus 201.7, 95% CI: 183.2 to 220.2; p < 0.001). The least-squares mean difference between the 2 treatments was -122.9 (95% CI: -166.7 to -79.2, p < 0.001), and -47.5 (95% CI: -79.5 to -15.4, p = 0.004), in carriers and noncarriers …
-
Nanoparticulate silica : new absorbents for PTE extraction from aqueous media and VOCs from indoor air
… MCM-41. The maximum adsorption capacity at 111.1 mg g-1 was calculated according to the Langmuir isotherm model. Silica materials with different pore sizes were used to extract Cr (VI) ions from water and the results were examined using kinetics models. Different adsorption behaviours were …
-
Synthesis And Characterization Of Additive Manufactured Functional Composites For Biomedical Applications
… infill exhibiting the highest contact angle of ~111.1°. In the second phase, SLS printed nylon 12 (polyamide 12 (PA 12)) composites reinforced with 5 and 10 vol% laver seaweed, dried distillers grains with solubles (DDGS), and hydroxyapatite (HA) were fabricated and characterized. Composites with …
-
Acute and Chronic Analysis of the Safety and Efficacy of Dose Dependent Creatine Nitrate Supplementation and Exercise Performance
… 95% CI -9.2, 91.0; CrN-H, 60.9, 95% CI 10.8, 111.1, Watts) and average power. Creatine nitrate was well-tolerated, demonstrated similar performance benefits to 3 g CrM, and was void of significant hemodynamics or blood enzymes changes associated with supplement safety.
-
Effect of vitamin supplementation on the ingestive, digestive, and ruminal parameters of Nellore cattle
… vitamin per kg of DM were: 3.3 mg of biotin, 111.1 mg of niacin, 28.9 mg of thiamine, 6666.7 IU of vitamin A, 5111.1 IU of vitamin D 3 , and 70 IU of vitamin E. Each experimental period lasted 25 days, with 14 days of adaptation to the diets and 11 days for data collection. Dry matter and …
-
The perception of sweet, bitter and fatty acid taste and sensitivity to fat by mouthfeel and olfaction : associations with dietary intake, eating behaviour and obesity in premenopausal women : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Nutritional Science at Massey University, Albany, New Zealand
… sugars and starch (199.4 ± 51.1, 87.9 ± 27.4 and 111.1 ± 34.6 g/day) when compared to sweet taste dislikers (165.9 ± 48.7, 71.4 ± 25.2 and 94.1 ± 34.7 g/day, P< 0.001, P< 0.01, and P< 0.01, respectively), however, this comparison was not significant in Pacific women. NZ European women in the sweet …
-
Mechanism of weight loss in the morbidly obese following ileogastrostomy and validation of reported energy intake in normal-weight and morbidly obese subjects
… the overall research. Average body weight (111.1±3.2 kg, n=7) of the subjects completing the 3-month measurement decreased by 5.2, 4.2 and 7.8 kg during each of the three months. There was a significant decline (p<O.0001) in fat-free mass (FFM) and fat mass (FM) measured by both IDS and BIA …
Page 1 of 2