Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 34 for “"120 KHz"”

  1. The Effect of 120-kHz Ultrasound on Thrombolytic Efficacy in Porcine Thromboembolism Models

    … The addition of Definity® microbubbles and 120-kHz ultrasound to rt-PA treatment has been shown to enhance lytic activity in vitro and ex vivo. However, preclinical trials must be completed in an animal model such as pigs prior to human clinical trials. One porcine thrombosis model is the …

    ohiolink Repository record for The Effect of 120-kHz Ultrasound on Thrombolytic Efficacy in Porcine Thromboembolism Models (opens in a new tab)

  2. Hearing and Echolocation in Stranded and Captive Odontocete Cetaceans

    … whales tested had the best sensitivity at 40 kHz. The juveniles had greater high frequency sensitivity than the adult pilot whales. Cutoff frequencies were between 80 and 120 kHz. Hearing sensitivity was determined for the two mother/calf pairs of Risso's dolphins (Grampus griseus) before and …

    usf Repository record for Hearing and Echolocation in Stranded and Captive Odontocete Cetaceans (opens in a new tab)

  3. Advanced Thermosonic Wire Bonding Using High Frequency Ultrasonic Power: Optimization, Bondability, and Reliability

    Gold wire bonding typically uses 60 KHz ultrasonic frequency. Studies have been reported that increasing ultrasonic frequency from 60KHz to 120KHz can decrease bonding time, lower bonding temperature, and/or improve the bondability of Au metalized organic substrates. This thesis presents a …

    calpoly Repository record for Advanced Thermosonic Wire Bonding Using High Frequency Ultrasonic Power: Optimization, Bondability, and Reliability (opens in a new tab)

  4. Ultrasound-enhanced drug delivery in a perfused ex vivo artery model

    … cavitation through the use of intermittent 120-kHz ultrasound with quiescent periods to allow contrast agent inflow was developed. Using this insonificaiton method, sonothrombolysis was studied in ex vivo porcine carotid arteries using a 120-kHz center frequency and 0.44 MPa peak-to- peak …

    ohiolink Repository record for Ultrasound-enhanced drug delivery in a perfused ex vivo artery model (opens in a new tab)

  5. The Role of Cavitation in Enhancement of rt-PA Thrombolysis

    … rectified diffusion and cavitation thresholds at 120 kHz. Stable and inertial cavitation thresholds were measured experimentally and clots were exposed to cavitational activity in the presence of rt-PA. Subsequently, an approach for cavitation nucleation using infusion of a contrast agent was …

    ohiolink Repository record for The Role of Cavitation in Enhancement of rt-PA Thrombolysis (opens in a new tab)

  6. Ultrasound-Induced Hyperthermia in <i>Ex Vivo</i>Clotted Blood and Cranial Bone

    … attenuation in blood clots was determined from 120 kHz to 3.5 MHz at room temperature 20 ± 2 °. It ranged from 0.10 to 0.30 Np/cm in porcine clots and from 0.09 to 0.23 Np/cm in human clots. The magnitudes of specific heat and thermal conductivity of porcine clotted blood are (3.2 ± 0.5) × 10³ …

    ohiolink Repository record for Ultrasound-Induced Hyperthermia in <i>Ex Vivo</i>Clotted Blood and Cranial Bone (opens in a new tab)

  7. Frequency-time correlation of surface scattered underwater sound.

    … study forward scattered underwater sound. A 10 kHz saw-tooth signal was used to drive an omnidirectional source to insonify the rough surface. Direct and reflected path sound signals to a point hydrophone were separated by appropriate gating and the reflected path signal was analyzed for up to 2 …

    nps Repository record for Frequency-time correlation of surface scattered underwater sound. (opens in a new tab)

  8. A Synchronous Distributed Control and Communication Network for High-Frequency SiC-Based Modular Power Converters

    … of 25 ns accuracy is proposed and verified for a 120 kHz SiC-based impedance measurement unit (IMU) with cascaded H-bridge PEBBs. An improved synchronization method with additional analog circuits is further implemented and verified with sub-ns synchronization accuracy.

    vt Repository record for A Synchronous Distributed Control and Communication Network for High-Frequency SiC-Based Modular Power Converters (opens in a new tab)

  9. Distribution, patchiness, and behavior of Antarctic zooplankton, assessed using multi-frequency acoustic techniques

    … volume backscattering at the single frequency of 120 kHz was first examined as an index of the overall biomass of zooplankton. Distinct spatial and seasonal patterns were observed that coincided with advective features. Improved parameterization was then achieved for a theoretical model of …

    mit Repository record for Distribution, patchiness, and behavior of Antarctic zooplankton, assessed using multi-frequency acoustic techniques (opens in a new tab)

  10. Ultraharmonic and Broadband Cavitation Thresholds for Ultrasound Contrast Agents in an In-Vitro Flow Model

    … human clot model in flow exposed to an UCA and 120-kHz pulsed or continuous wave ultrasound. Two UCAs were used to nucleate cavitation, Definity® and echogenic liposomes (ELIP). Definity® is a commercially available UCA, and ELIP are potential theragnostic agents for the treatment of stroke, …

    ohiolink Repository record for Ultraharmonic and Broadband Cavitation Thresholds for Ultrasound Contrast Agents in an In-Vitro Flow Model (opens in a new tab)

  11. INVESTIGATING THE CHARACTERISTICS OF THE SOUTHERN BEAUFORT SEA USING ACOUSTICAL OCEANOGRAPHY SENSORS DURING ICEX-18

    During Ice Exercise (ICEX) 2018, a 120-kHz echosounder was used to investigate the ocean environment underneath the Arctic ice sheet in the southern Beaufort Sea down to a depth of 200 meters. Returns from the echosounder, coupled with data from an Acoustic Doppler Current Profiler (ADCP) and a …

    nps Repository record for INVESTIGATING THE CHARACTERISTICS OF THE SOUTHERN BEAUFORT SEA USING ACOUSTICAL OCEANOGRAPHY SENSORS DURING ICEX-18 (opens in a new tab)

  12. The use of multibeam and split-beam echo sounders for assessing biomass and distribution of spring-spawning Atlantic cod in the Gulf of Maine

    … between target strength and length for 38-kHz and 120-kHz split-beam echo sounders and a 300-kHz multibeam echo sounder, and characterize other factors affecting backscattering of sound.The multibeam echo sounder detected a small and large reduction in volume backscatter proportional to …

    unh-thes Repository record for The use of multibeam and split-beam echo sounders for assessing biomass and distribution of spring-spawning Atlantic cod in the Gulf of Maine (opens in a new tab)

  13. Dual-frequency acoustic seabed classification on the Scotian shelf, Canada

    … potential of using two acoustic frequencies, 38 kHz and 120 kHz, from a single beam echo sounder for acoustic seabed classification on the Scotian Shelf, Canada. The main goals were to assess the characteristics of near-nadir acoustic backscatter as a function of seabed substrate properties and …

    newfoundland Repository record for Dual-frequency acoustic seabed classification on the Scotian shelf, Canada (opens in a new tab)

  14. Purification of metals through filtration and electromagnetic separation

    … separation experiments at frequencies of 63 - 120 kHz and aluminum filtration experiments using both conventional Al₂O₃ filters and AlF₃ coated Al₂O₃ filters were carried out by flowing molten aluminum through, and partly solidified in the filter bed followed by analysis of the metal and filter …

    must-thes Repository record for Purification of metals through filtration and electromagnetic separation (opens in a new tab)

  15. Characterization of cell mechanics with atomic force microscopy : Mechanical mapping and high-speed microrheology

    … sur fibroblastes ont été réalisées entre 1Hz et 120 kHz, permettant d’étendre de deux ordres de grandeur l’échelle de fréquences explorée. Ce travail montre une réponse cellulaire aux stimulations à haute fréquence plus visqueuse qu’à basse fréquence, mais suggèrent aussi une réponse bien plus …

    star-france Repository record for Characterization of cell mechanics with atomic force microscopy : Mechanical mapping and high-speed microrheology (opens in a new tab)

  16. Third-order continuous-time sigma delta coulomb-counter achieving 2.8pJ/conv FOM with 1.2V supply voltage in 55nm BCD process

    … achieves a SINAD/SFDR of 71/80 dB in the same 120 kHz bandwidth while dissipating 1.94 mW from a 1.2 V power supply. The figures of merit of the two modulators are 0.69 pJ/conv and 2.8 pJ/conv, respectively. The fixed-point multi-rate decimating digital filter is designed and simulated in …

    nanyang Repository record for Third-order continuous-time sigma delta coulomb-counter achieving 2.8pJ/conv FOM with 1.2V supply voltage in 55nm BCD process (opens in a new tab)

  17. Developments in fish detection using broadband acoustic doppler current profiler

    … bottom-mounted frame equipped with a 600 kHz RD Instruments Workhorse ADCP alongside a 120 kHz BioSonics DTX Submersible Split-Beam Echosounder system. The deployments took place in Grand Passage, Nova Scotia, a tidal channel that has the potential for in-stream tidal generation. The …

    newfoundland Repository record for Developments in fish detection using broadband acoustic doppler current profiler (opens in a new tab)

  18. Ultrasonic acoustic health monitoring of ball bearings using neural network pattern classification of power spectral density

    … in this study are in the ultrasonic range (20-120 kHz), which is significantly higher than the majority of the research in this area thus far. A direct benefit of working in this frequency range is the inherent directionality of the microphones capable of measurement in this range, which …

    vt Repository record for Ultrasonic acoustic health monitoring of ball bearings using neural network pattern classification of power spectral density (opens in a new tab)

  19. Mutual interference investigation of CEBus and X-10 powerline signaling

    … at 10 kBps using spread spectrum in the 100-400 kHz band while X-l0 sends 60 Bps using bursts of 120 kHz carrier on the power line. However, these two signals may destructively interfere when present simultaneously. X-10 is narrow band and interferes with the CEBus spread spectrum signal. This …

    njit Repository record for Mutual interference investigation of CEBus and X-10 powerline signaling (opens in a new tab)

  20. Acoustic scattering of broadband echolocation signals from prey of Blainville's beaked whales modeling and analysis

    … ultrasonic echolocation signals (27 to 57 kHz) to search for, localize, and approach prey that generally consist of mid-water and deep-water shes and squid. Although it is well knownthat the spectral characteristics of broadband echoes from marine organisms are a strong function of size, …

    nps Repository record for Acoustic scattering of broadband echolocation signals from prey of Blainville's beaked whales modeling and analysis (opens in a new tab)

Page 1 of 2