Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 33 for “"18 MV"”.

  1. Portal scatter to primary dose ratio of 4 to 18 MV photon spectra incident on heterogeneous phantoms

    Electronic portal imagers designed and used to verify the positioning of a cancer patient undergoing radiation treatment can also be employed to measure the in vivo dose received by the patient. This thesis investigates the ratio of the dose from patient-scattered particles to the dose from primary …

    ubc Repository record for Portal scatter to primary dose ratio of 4 to 18 MV photon spectra incident on heterogeneous phantoms (opens in a new tab) Download PDF for Portal scatter to primary dose ratio of 4 to 18 MV photon spectra incident on heterogeneous phantoms (opens in a new tab)

  2. Valoración de la contaminación de neutrones producidos por un acelerador lineal de electrones (18 MV) de uso clínico

    … La energía nominal utilizada es de rx-18MV por ser la que produce mayor flujo de neutrones de los haces disponibles. Así mismo mediante el procedimiento teórico del método de Montecarlo hemos obtenido el espectro neutrónico junto al acelerador. Por último una dosimetría ambiental de la …

    sevilla Repository record for Valoración de la contaminación de neutrones producidos por un acelerador lineal de electrones (18 MV) de uso clínico (opens in a new tab)

  3. Monte Carlo Modeling of a Varian 2100C 18 MV Megavoltage Photon Beam and Subsequent Dose Delivery using MCNP5

    A Varian 2100C 18 MV photon beam has been modeled in this work using the MCNP5 Monte Carlo particle transport user code. The subsequent beam irradiation was also delivered to a water phantom and benchmarked against experimentally measured depth dose data. The model presented in this work …

    gatech Repository record for Monte Carlo Modeling of a Varian 2100C 18 MV Megavoltage Photon Beam and Subsequent Dose Delivery using MCNP5 (opens in a new tab)

  4. Προσομοιώσεις και μετρήσεις της ροής νετρονίων στο θάλαμο θεραπείας και κατά μήκος του λαβυρίνθου ιατρικού γραμμικού επιταχυντή 18 MV

    Γραμμικοί επιταχυντές υψηλής ενέργειας (>10 MV), παράγουν νετρόνια μέσω πυρηνικών αντιδράσεων (γ, n) με τα υλικά της κεφαλής τους. Αυτά τα νετρόνια πρέπει να παρθούν υπόψη στο σχεδιασμό της θωράκισης του θαλάμου θεραπείας. Σκοπός της παρούσας μελέτης είναι η εκτίμηση της ροής νετρονίων στο θάλαμο …

    athens Repository record for Προσομοιώσεις και μετρήσεις της ροής νετρονίων στο θάλαμο θεραπείας και κατά μήκος του λαβυρίνθου ιατρικού γραμμικού επιταχυντή 18 MV (opens in a new tab)

  5. Die Bedeutung des Unterschiedes zwischen den angewandten Photonenenergien 6 MV und 18 MV bei der Bestrahlung von Blut am Linearbeschleuniger

    … war es daher, zwei verschiedene Energien, 6 und 18 MV, die typischer Weise in der klinischen Routine verwendet werden, daraufhin zu untersuchen, ob sie in Transfusionsblut Radioaktivität induzieren und falls ja, in welcher Größenordnung. Weiterhin wurde im Rahmen dieser Arbeit ein klinisch …

    fu-berlin Repository record for Die Bedeutung des Unterschiedes zwischen den angewandten Photonenenergien 6 MV und 18 MV bei der Bestrahlung von Blut am Linearbeschleuniger (opens in a new tab)

  6. Determination of the bremsstrahlung spectra of a clinical linear accelerator using a Simpson iteration technique

    … dual energies. Photon energy spectra for 6 MV and 18 MV beams produced by Varian 6100 and Varian 2100C linear accelerators were determined to validate the consistency of the measured data and the modeling method. The resulting Simpson unfolded spectra were compared to the published 6 MV …

    ut-knoxville Repository record for Determination of the bremsstrahlung spectra of a clinical linear accelerator using a Simpson iteration technique (opens in a new tab)

  7. Κατανομή δόσης από φωτόνια υψηλής ενέργειας σε υλικό μικρού ατομικού αριθμού κοντά σε ανομοιογένειες

    … this end measurements were performed using 6 and 18 MV X-rays from a linear accelerator, the Varian Clinac DHX at the University General Hospital of Ioannina. Radiochromic films HD-810, MD-55 and ΕΒΤ3 were used for the experimental dose measurements. A flatbed scanner Microtek ScanMaker S480 was …

    greece Repository record for Κατανομή δόσης από φωτόνια υψηλής ενέργειας σε υλικό μικρού ατομικού αριθμού κοντά σε ανομοιογένειες (opens in a new tab)

  8. Evaluation of The Effectiveness of Anisotropic Analytical Algorithm In Flattened and Flattening-Filter-Free Beams For High Energy Lung Dose Delivery Using The Radiological Physics Center Lung Phantom

    … clinically used photon beams in the range from 6 MV to 18 MV. The measured dose distribution showed a good agreement with the calculated distribution using clinically acceptable criteria of ±5% dose or 3mm distance to agreement. These results show that in a heterogeneous environment a 3D pencil …

    uthsc Repository record for Evaluation of The Effectiveness of Anisotropic Analytical Algorithm In Flattened and Flattening-Filter-Free Beams For High Energy Lung Dose Delivery Using The Radiological Physics Center Lung Phantom (opens in a new tab)

  9. III-V-semiconductor subcell absorbers in silicon-based triple-junction solar cells

    … with a minimum loss to the radiative limit of 18 mV in a rear-heterojunction solar cell.<br>An optical parameter morphing method was optimised to generate continuous refractive index data for arbitrary absorber compositions. The robustness of the method was experimentally confirmed by a …

    freiburg-diss Repository record for III-V-semiconductor subcell absorbers in silicon-based triple-junction solar cells (opens in a new tab)

  10. Modelagem computacional de um acelerador linear e da sala de radioterapia para cálculo da dose efetiva em pacientes submetidos a tratamento de câncer de próstata

    … code, of a realistic computational model of a 10 MV VARIAN linear accelerator equipped with a highly detailed VARIAN HD120 multileaf collimator. Validation was achieved by comparing calculated percentage dose depths and lateral dose profiles with commissioning measurements (golden data) from the …

    brazil-uerj Repository record for Modelagem computacional de um acelerador linear e da sala de radioterapia para cálculo da dose efetiva em pacientes submetidos a tratamento de câncer de próstata (opens in a new tab)

  11. Monte Carlo conversion for the Australian primary standard of absorbed dose to water in high energy photon beams

    … of the other participant was 0.02 to 0.46% at 6 MV, 0.41 to 0.76% at 10 MV and 0.68 to 0.80% at 18 MV. All results for the 6 MV beam agreed within 1σ. At 10 MV one measurement agreed within 1σ. The remaining 10 MV comparisons and all comparisons at 18 MV differed by between 1σ and 2σ. In addition …

    adelaide Repository record for Monte Carlo conversion for the Australian primary standard of absorbed dose to water in high energy photon beams (opens in a new tab)

  12. Dosimetry at extreme non-charged particle equilibrium conditions using Monte Carlo and specialized dosimeters

    … and water/steel interfaces irradiated with 6 and 18 MV photon beams. MC calculations were used, along with Acuros XB, anisotropic analytical algorithm (AAA), GafChromic EBT2 film, and MOSkin dosimeters. PDDs were calculated and measured in these heterogeneous phantoms. The result of this study …

    uvic Repository record for Dosimetry at extreme non-charged particle equilibrium conditions using Monte Carlo and specialized dosimeters (opens in a new tab)

  13. Evaluation of an amorphous silicon electronic portal imaging device for use in radiation therapy dosimetry

    … same dose with varying dose rates for both 6 and 18 MV photons. Next the water equivalent depth of the inherent buildup material on the EPID is determined. The inherent build-up of the portal imaging device was found to be 1.4 ± 0.2 cm for 6 MV and 2.2 ± 0.2 cm for 18 MV. A comparison of EPID and …

    ubc Repository record for Evaluation of an amorphous silicon electronic portal imaging device for use in radiation therapy dosimetry (opens in a new tab) Download PDF for Evaluation of an amorphous silicon electronic portal imaging device for use in radiation therapy dosimetry (opens in a new tab)

  14. Mechanism of oxygen reduction on platinum in netural saline and effects of interstitial fluid

    … the neutral pH region. The Tafel slope was 135 + 18 mv and the reaction orders 1.1 and 0.19 with respect to oxygen and hydrogen ion respectively. These criteria were interpreted as being consistent with a consecutive adsorption and one electron transfer rate controlling step as follows: O2 …

    missouri Repository record for Mechanism of oxygen reduction on platinum in netural saline and effects of interstitial fluid (opens in a new tab)

  15. Contribuição ao uso do óleo de urucum no desenvolvimento de fitomedicamentos: avaliação da toxicidade oral aguda do óleo de urucum e caracterização de géis de carbopol contendo nanocarreadores lipídicos e a fração insaponificável de urucum

    … lower than 0.2, and a zeta potential up to -18 mV, indicating good stability for 90 days. HPLC analysis indicated the presence of tocotrienol in the unsaponifiable fraction of urucum, with a coefficient of determination (R²) of 0.9997, highlighting the adequacy of the model for quantifying …

    brazil-ufrn Repository record for Contribuição ao uso do óleo de urucum no desenvolvimento de fitomedicamentos: avaliação da toxicidade oral aguda do óleo de urucum e caracterização de géis de carbopol contendo nanocarreadores lipídicos e a fração insaponificável de urucum (opens in a new tab)

  16. Calibration of TLD700: LiF for clinical radiotherapy beam modalities and verification of a high dose rate brachytherapy treatment planning system.

    … to known doses of radiation from nominal 6 MV and 18 MV photon beams as well as nominal 6 MeV, 9 MeV, 12 MeV, 16 MeV and 20 MeV electron beams from a Linear Accelerator. The TLDs were read and the response from each beam was normalised to that from the 6 MV beam. The TLDs were also exposed …

    adelaide Repository record for Calibration of TLD700: LiF for clinical radiotherapy beam modalities and verification of a high dose rate brachytherapy treatment planning system. (opens in a new tab)

  17. Design, Synthesis, and Evaluation of Oleyl-WRH Peptides for siRNA Delivery

    … stable range of zeta potential values (13-18 mV at N/P 40). All peptide:siRNA complexes showed an adequate binding affinity and serum stability at N/P ≥40. The peptide:siRNA complexes were found to be non-cytotoxic at N/P 40 (~20 μM) for 72 h in MDA-MB-231, MCF-7, SK-OV-3, and HEK-293 …

    chapman Repository record for Design, Synthesis, and Evaluation of Oleyl-WRH Peptides for siRNA Delivery (opens in a new tab)

  18. Μέτρηση ροής νετρονίων σε ιατρικό γραμμικό επιταχυντή 18MV

    … γραμμικούς επιταχυντές υψηλής ενέργειας (> 10MV) τα νετρόνια παράγονται κυρίως μέσω αλληλεπιδράσεων (γ, n) των φωτονίων με πυρήνες υψηλού ατομικού αριθμού υλικών από τα οποία είναι κατασκευασμένα τα δομικά μέρη της κεφαλής όπως ο στόχος, οι κατευθυντήρες και η θωράκιση της. Αυτά τα νετρόνια …

    athens Repository record for Μέτρηση ροής νετρονίων σε ιατρικό γραμμικό επιταχυντή 18MV (opens in a new tab)

  19. Analysis and design of 7T sense amplifiers in 28 nm FD-SOI CMOS process

    … will be presented, which are valid for VDD=350 mV, 450 mV and 550 mV. Small-signal capacitances, transconductances and channel conductances are analyzed and mod- eled in order to provide compact and fast parameter evaluation. Lastly, a figure of merit (FoM) relating speed and yield is proposed. …

    brazil-uerj Repository record for Analysis and design of 7T sense amplifiers in 28 nm FD-SOI CMOS process (opens in a new tab)

  20. Absolute Dose Verification in Intensity Modulated Radiation Fields

    … property of Kodak XV film was verified for 6 and 18 MV photon beams. A technique to quantify film over response to low photon energy was presented. Monte Carlo calculations were used to validate measurements obtained by this technique and thereafter, it was applied to several clinical IMRT fields. …

    uiuc Repository record for Absolute Dose Verification in Intensity Modulated Radiation Fields (opens in a new tab)

Page 1 of 2