Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 108 for “"2µm"”

  1. Lidar 2µm à source hybride fibrée/solide pour la télédétection du CO2 atmosphérique

    Dans une perspective de réchauffement climatique global, il est essentiel de mieux comprendre et caractériser, à l’échelle planétaire, les cycles des principaux gaz à effet de serre et notamment du dioxyde de carbone (CO2). Jusqu’ici, l’observation du CO2 depuis l’espace a été réalisée avec des …

    star-france Repository record for Lidar 2µm à source hybride fibrée/solide pour la télédétection du CO2 atmosphérique (opens in a new tab)

  2. Thulium-doped fiber sources for novel applications

    Very recently, the 2µm wavelength region is attracting growing attention as a potential new transmission window for optical communications to accommodate the everincreasing internet traffic. This is underpinned by the emerging technology of hollowcore photonic bandgap fibers (HC-PBGFs), which holds …

    soton Repository record for Thulium-doped fiber sources for novel applications (opens in a new tab)

  3. Étude et optimisation d’un capteur d’images à collection de trous : réduction des tensions de fonctionnement et des dimensions du pixel PhotoGate

    … à partir un pixel précédemment développé de 2µm fonctionnant sous 3.5V. Différentes structures constitutives du pixel sont remises en oeuvre, avec des nouveaux choix de paramètres technologiques, géométriques et électriques. Elles sont analysées et optimisées par simulations TCAD et/ou Spice. …

    star-france Repository record for Étude et optimisation d’un capteur d’images à collection de trous : réduction des tensions de fonctionnement et des dimensions du pixel PhotoGate (opens in a new tab)

  4. Herstellung und Charakterisierung von Gruppe III-Nitrid Laserdioden

    … mit einer minimalen Rippenbreite von 2µm ermöglichte. Die Verringerung der minimalen Rippenbreite von 4µm auf 2µm führte zu einer Verbesserung des Schwellenstromes von 500µm langen Laserdioden von 205mA auf 115mA. Durch eine schonendere Prozeßführung konnte die Betriebspannung der …

    freiburg-diss Repository record for Herstellung und Charakterisierung von Gruppe III-Nitrid Laserdioden (opens in a new tab)

  5. Infrarot-Diodenlaser auf der Basis der III-V-Antimonide

    … bei Lasern mit einer Emissionswellenlänge von 2µm durch die defektassistierte Rekombination dominiert. Dieser Effekt bestimmt daher die Höhe und Temperaturabhängigkeit des Schwellenstromes bis zur Raumtemperatur, erst bei höheren Temperaturen bewirkt der stärker werdende Einfluss der …

    freiburg-diss Repository record for Infrarot-Diodenlaser auf der Basis der III-V-Antimonide (opens in a new tab)

  6. Characterizing porosity for 3d printed hydroxyapatite scaffolds of varying density and composition

    … pore diameter size: (i) ceramic pores (100nm – 2µm), (ii) intermediate pores (2µm – 70 µm), and (iii) structural pores (>70µm). Highly porous scaffolds were designed with a CAD software and printed with an ‘ink’ composed of a stable suspension of colloidal HA and some contained a fugitive pore …

    okstate Repository record for Characterizing porosity for 3d printed hydroxyapatite scaffolds of varying density and composition (opens in a new tab)

  7. Pharmaceutical impurity assay method development using core-shell stationary phase technology for HPLC and evaluation of stationary and mobile phases for an orthogonally selective SFC impurity assay

    … best separation in the shortest time”. While sub 2µm fully porous particle stationary phases have addressing this demand for faster more efficiency separations, a research focus which has recently seen a resurgence has been core-shell particle technologies which offer similar performance to sub 2 …

    dcu Repository record for Pharmaceutical impurity assay method development using core-shell stationary phase technology for HPLC and evaluation of stationary and mobile phases for an orthogonally selective SFC impurity assay (opens in a new tab)

  8. MEMS micro-bridge actuator for potential application in optical switching

    … oxide, 1µm thick high-stress PECVD oxide and 2µm thick heavily phosphorus doped silicon. The legs, on the other hand, are 2µm thick single layer heavily phosphorus doped silicon. Both legs and springs provide elastically constrained boundary conditions at the supporting ends, without of which …

    unsw Repository record for MEMS micro-bridge actuator for potential application in optical switching (opens in a new tab)

  9. Diabetes microvascular complications: the role of advanced glycated end‐products (AGEs)

    … using the fluorescent indicator dye Fura2-AM (2µM). Vasodilation studies were performed in isolated, pressurized first-order (1A) arterioles from the rat cremaster muscle. Results: Exposure of BAECs to AGEs for 5 min caused an elevation in basal [Ca2+] and a concentration-dependent attenuation …

    unsw Repository record for Diabetes microvascular complications: the role of advanced glycated end‐products (AGEs) (opens in a new tab)

  10. Fabrication of Long Range Surface Plasmon Polariton Bragg Waveguide Biosensors on Cytop and Multilayer Substrates

    … gratings having a step-in-width from 8µm to 2µm, a 50% duty cycle and a period of 1690nm to 1800nm, was achieved with bi-layer lithography and UV exposure. A gold thickness of 35nm±5% and surface roughness of better than 2nm rms and average was achieved using thermal vacuum chamber …

    carleton Repository record for Fabrication of Long Range Surface Plasmon Polariton Bragg Waveguide Biosensors on Cytop and Multilayer Substrates (opens in a new tab)

  11. Optical receivers and photodetectors in 130nm CMOS technology

    … efficiencies of 12% and 2% were measured on the 2µm and 0.2µm thick SOI, respectively . Capacitances of 40fF were measured while the dark current was 5pA for –3V bias and 500 µA for -9V bias. The photodetectors were also monolithically integrated with a waveguidegrating coupler (WGC). For a …

    texas Repository record for Optical receivers and photodetectors in 130nm CMOS technology (opens in a new tab) Restricted access

  12. APPLICATION OF TOPOGRAPHY TO DIRECT DIFFERENTIATION OF PLURIPOTENT STEM CELLS

    … have determined that the topographical cues from 2µm gratings increase the rate of hPSC neural differentiation, and that additional periods of culture on topography can further increase the rate of hPSC neural differentiation. We envisage that this work can be applied to future neural …

    nus Repository record for APPLICATION OF TOPOGRAPHY TO DIRECT DIFFERENTIATION OF PLURIPOTENT STEM CELLS (opens in a new tab)

  13. Affordable flexible hybrid manipulator for miniaturised product assembly

    … a low-cost positioning accuracy better than 2µm within a workspace of 4.4×4.4mm2. Finally, a hybrid manipulator is designed to assemble mobile-phone cameras and sensors automatically. A conventional robot manipulator is used to pick and place the parts in coarse mode while the aluminium CMMS …

    heriot-watt Repository record for Affordable flexible hybrid manipulator for miniaturised product assembly (opens in a new tab)

  14. Doughnut-shaped beam generation in solid-state and fibre lasers

    … to radial polarization in both 1µm and 2µm regimes using continuously space-variant lambda/4 or lambda/2 waveplates (also called S-waveplates), fabricated by a recently developed femtosecond writing technique. In the one-micron wavelength regime, the lambda/2 S-waveplate can transform a …

    soton Repository record for Doughnut-shaped beam generation in solid-state and fibre lasers (opens in a new tab)

  15. Etude couplée des fractionnements isotopiques du LI, B et U dans des profils d'altération : exemple du bassin versant du Strengbach (Vosges, France)

    … versant en se concentrant sur la fraction <2µm. Cela permettra de voir si les observations faites dans le premier profil se retrouvent dans les autres profils et si nous sommes capables de remonter au régime d’altération. Étudier de manière préliminaire comment évolue le signal isotopique de …

    star-france Repository record for Etude couplée des fractionnements isotopiques du LI, B et U dans des profils d'altération : exemple du bassin versant du Strengbach (Vosges, France) (opens in a new tab)

  16. Combinaison monolithique de lasers à cascade quantique par couplage évanescent

    … fois, des dispositifs jusqu’à 32 émetteurs de 2µm de larges, émettant en phase par couplage évanescent. De plus, nous mettons en évidences des résistances thermiques record. Ces résultats mettent en évidence la possibilité de fabriquer des sources de hautes puissances (supérieures à 10W) dans …

    star-france Repository record for Combinaison monolithique de lasers à cascade quantique par couplage évanescent (opens in a new tab)

  17. Micro-transfer printing for visible light communications applications

    … multi-functional integrated photonic devices.;2µm-thick 100µm x 100µm LEDs are transfer printed onto these non-native, capability enhancing, substrates using a modified nano-lithography system. Blue-emitting µLEDs in this thin, transfer printable format, were integrated into an array of …

    strathclyde Repository record for Micro-transfer printing for visible light communications applications (opens in a new tab)

  18. FABRICATION OF ALL-SOLID-STATE THIN-FILM LITHIUM-ION MICROBATTERY

    … per thickness of cathode material (~40 µAhcm-2µm-1) to commercially available thin-film discrete microbatteries.

    nus Repository record for FABRICATION OF ALL-SOLID-STATE THIN-FILM LITHIUM-ION MICROBATTERY (opens in a new tab)

  19. A study of nickel microwires as catalysts in the liquid phase hydrogenation of alkenes

    … reaction conditions. This study shows that 2µm diameter nickel microwires exhibit very high activity and a long life time as compared to other commonly used industrial nickel catalysts. This tudy also shows that the activity of the nickel microwires is affected by the diameter of the wire. …

    ucf Repository record for A study of nickel microwires as catalysts in the liquid phase hydrogenation of alkenes (opens in a new tab)

  20. Bubble Mediated Surface Modification in the Copper Electropolishing System

    … generated feature heights ranging from 0.5 - 2µm and surface area increases in excess of 30% were obtained. The samples demonstrated a macroscopic optical dullness characteristic of this type of surface roughening. Investigations as to their applicability in surface enhanced Raman spectroscopy …

    mcmaster Repository record for Bubble Mediated Surface Modification in the Copper Electropolishing System (opens in a new tab)

Page 1 of 6