Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"200 kV"”.

  1. Analýza vlivu optických parametrů transmisního elektronového mikroskopu (TEM) na zobrazení

    … jsou pořízena při použití urychlovacího napětí 200 kV. Podmínky pro dosažení nejlepšího informačního limitu jsou diskutovány.

    brno-tech Repository record for Analýza vlivu optických parametrů transmisního elektronového mikroskopu (TEM) na zobrazení (opens in a new tab)

  2. Laser triggered spark gap using fiber optic transmission

    … Ar-N^ gas mixture, and a charging voltage of 200 kV. The single strand, 1 mm, quartz, optical fiber is selected specifically for high power transmission capability. Laser pulses of 4 MW are coupled into and transmitted by the fiber with no observed damage. The overall optical system …

    ttu Repository record for Laser triggered spark gap using fiber optic transmission (opens in a new tab)

  3. Electron Beam Induced Current in Wide Bandgap Semiconductors using Scanning Transmission Electron Microscopy

    … electron beam/specimen interaction volume at > 5 kV, as well as large collection losses due to carrier recombination at the surface at < 5 kV. This dissertation addresses the previous issues of SEM EBIC with a non-traditional bulk scanning transmission electron microscopy (STEM) EBIC technique …

    maryland Repository record for Electron Beam Induced Current in Wide Bandgap Semiconductors using Scanning Transmission Electron Microscopy (opens in a new tab)

  4. Aberration Corrector for an Exclusively Low-Voltage Electron Microscopy

    … u konvenčních elektronových mikroskopů (50-200 kV) stává standardem. Nicméně zabudování korektoru do malého stolního prozařovacího mikroskopu pracujícího s nízkým urychlovacím napětím je stále výzva. Velmi vhodným řešením korekce otvorové vady u takovýchto přístrojů se zdá být koncept …

    brno-tech Repository record for Aberration Corrector for an Exclusively Low-Voltage Electron Microscopy (opens in a new tab)

  5. Electronic phenomena in liquid argon and liquid helium

    … in argon had been measured in fields between 2 kV/cm. and 200 kV/cm., the high field values agreeing with the order of magnitude previously reported. The scattering cross section for electrons is found to be of the order one hundredth that observed in gaseous argon. The low mobility of positive …

    ubc Repository record for Electronic phenomena in liquid argon and liquid helium (opens in a new tab) Download PDF for Electronic phenomena in liquid argon and liquid helium (opens in a new tab)

  6. High-Voltage Measurements Using Slab-Coupled Optical Sensors

    … ignition coil circuit, a Marx generator, and a 200 kV generator used in a capacitor discharge configuration. These measurements show the SCOS' ability to measure at least 111 kV capacitor discharges with 6.6 ns rise times and other various high voltage waveforms.

    byu Repository record for High-Voltage Measurements Using Slab-Coupled Optical Sensors (opens in a new tab) Download PDF for High-Voltage Measurements Using Slab-Coupled Optical Sensors (opens in a new tab)

  7. Design and evaluation of a Monte Carlo model of a low-cost kilovoltage x-ray arc therapy system

    … first step, the kilovoltage x-ray arc therapy or KVAT system was modeled using the EGSnrc BEAMnrc and DOSXYZnrc Monte Carlo software tools. For this initial study 200 kV arc-therapy was simulated on cylindrical water phantoms of two sizes, each of which contained a variety of planning target …

    uvic Repository record for Design and evaluation of a Monte Carlo model of a low-cost kilovoltage x-ray arc therapy system (opens in a new tab)

  8. Design and Optimisation of Terahertz Frequency Photoconductive Antenna Arrays on Optically Transparent Insulating Substrates

    … a large area PCA device capable of producing ∼ 200 kV/cm, the largest THz field strengths to date from LT-GaAs PCA devices on sapphire substrates. Also presented in this work is an investigation of LT-GaAs PCAs operated at an excitation wavelength of 1030 nm. The generation characteristics are …

    whiterose Download PDF for Design and Optimisation of Terahertz Frequency Photoconductive Antenna Arrays on Optically Transparent Insulating Substrates (opens in a new tab)

  9. Study of early light emission from anode-initiated surface flashover in vacuum

    … is introduced which is capable of greater than 200 kV pulses with rise times on the order of a few tens of nanoseconds. The positive 45° flashover geometry is designed to provide similar field conditions to the insulator stacks of large scale pulsed power machines while improving diagnostic …

    ttu Repository record for Study of early light emission from anode-initiated surface flashover in vacuum (opens in a new tab)

  10. Bulk ceramic bismuth ferrite substituted with rare earths: Synthesis and characterisation

    … exhibited high dielectric breakdown (160-200 kV/cm) and were cycled above their coercive field, achieving maximum peak-to-peak strains of approximately 0.2-0.3% and remnant polarisations of 20-50 µC/cm2. However, no enhancement of the piezoelectric properties was observed at the MPB. This …

    unsw Repository record for Bulk ceramic bismuth ferrite substituted with rare earths: Synthesis and characterisation (opens in a new tab)

  11. Preparation and characterization of lead lanthanum titanate thin films by metalorganic decomposition

    … temperature of around 16.1 μC/cm² at a field of 200 kV/cm and no sign of polarization loss or breakdown was observed up to 10<sup>10</sup> cycles under the accelerated degradation breakdown test.

    vt Repository record for Preparation and characterization of lead lanthanum titanate thin films by metalorganic decomposition (opens in a new tab)

  12. Radiosensitivierung durch iodhaltige DNA-bindende Liganden: Charakterisierung der Auger-Elektronen-Verstärkung durch verschiedene Strahlenqualitäten und Modulatoren

    … unterschiedlichen Beschleunigungspannungen (32 kV und 200 kV) untersucht. Jedoch führte auch hier die PI-Markierung nicht zu der erwarteten stärkeren DNA-Schädigung bei 200 kV. Die Untersuchung zur UV-Bestrahlung ergab für die Wellenlänge 254 nm einen DNA-toxischen Effekt. Durch die …

    qucosa-diss

  13. Reliability Assessment and Modeling of High-k Dielectric Thin Films

    … over voltage acceleration in the range of 100 kV/cm to 200 kV/cm were found. This indicates that accelerated lifetime testing in the temperature range below 150 °C is possible and caution is required for voltage acceleration. The results of this study are also published in Ref. (a). Closing the …

    qucosa-diss

  14. Thermal in situ TEM experiment on nanoscale indium islands

    … Effect of the acceleration voltage at 120 and 200 kV is compared. The electron beam illuminating area on the sample is estimated using a standard TEM grating sample. The beam currents are measured using the TEM fluorescent screen, which is independently calibrated as part of this work. A custom …

    chalmers Repository record for Thermal in situ TEM experiment on nanoscale indium islands (opens in a new tab)

  15. Control and application of VSC-HVDC systems for grid connection

    … series connection of two 12-pulse bridges of 400 kV each with a rated DC voltage of 800 kV per pole. Innovative solutions have been implemented to fully meet the extended requirements for ultra-high voltage bulk power transmission using thyristor-based converters. However, it has some …

    ets-quebec Download PDF for Control and application of VSC-HVDC systems for grid connection (opens in a new tab)

  16. Electron Beam Tomography of Recording Head Fields

    … mode of Lorentz microscopy implemented on a 200 kV scanning transmission instrument provides a novel technique for recording head field investigations and in particular the acquisition of the experimental data sets required for field reconstruction. The absolute determination of the recording …

    glasgow Download PDF for Electron Beam Tomography of Recording Head Fields (opens in a new tab)

  17. Modifikation der Strahlenreaktion der Mundschleimhaut (Maus) durch Hemmung der Stickstoffmonoxid-Synthase mittels nitro-L-Arginin-Methyl-Ester (L-NAME)

    … kommen die perkutane Schnauzenbestrahlung (200 kV Röntgenstrahlung) und/oder die lokale Bestrahlung (25 kV Röntgenstrahlung) eines 3·3 mm2 großen Testfeldes der Zungenunterseite der Maus zum Einsatz. In Fraktionierungsprotokollen werden 5x3 Gy/Woche über 1 (Tage 04) sowie 2 Wochen (Tage 0-4, …

    qucosa-diss

  18. Establishment of the Physical and Technical Prerequisites for the Determination of the Relative Biological Effectiveness of Low-energy Monochromatic X-rays

    … of Technische Universität Dresden. The RBE of 10 kV and 25 kV X-rays relative to 200 kV X-rays was determined. The RBE was found to be in the range from 1.0 to 1.4, depending on the used radiation quality, cell line and the biological endpoint, in agreement with previously published data for the …

    qucosa-diss

  19. Nelineární zobrazení v 100 keV transmisním elektronovém mikroskopu

    … s reálnými daty při urychlovacích napětí 100, 200 a 300 kV. Vliv jednotlivých nelineárních členů na pozorované rozlišení je diskutován.

    brno-tech Repository record for Nelineární zobrazení v 100 keV transmisním elektronovém mikroskopu (opens in a new tab)