Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 8 of 8 for “"241Am source"”.
-
ΜΕΛΕΤΗ ΦΑΣΜΑΤΩΝ COMPTON ΑΠΟ ΜΟΝΟΚΡΥΣΤΑΛΛΟΥΣ ΝΙΚΕΛΙΟΥ ΜΕ ΣΚΕΔΑΣΗ ΑΚΤΙΝΩΝ-Γ
… ON NICKEL USING 59.54 KEV Γ-RAYS FROM A 241AM SOURCE ALONG THE [100], [110], AND [111] DIRECTIONS. A VERY WELL FIXED SCATTERING RECTOR K RESULTING TO A VERY SMALL GEOMETRICAL RESOLUTIONIS USED. THIS YIELDS IN A SMALLER ASYMMETRY IN THE FINAL COMPTON PROFILES. WITH THE ABOVE EXPERIMENTAL …
-
A gallium arsenide CCD X-Ray detector
… response to radiation, six discrete X-Ray sources with energies ranging from 8 KeV to 60 keV were impinged on the device. An algorithm was developed to convert events detected by the CCD into spectra characteristic of each X-Ray source. The range of energies detectable and the energy …
-
Improved N-Type 4h-Sic Epitaxial Layer Radiation Detectors and Noise Analysis of Front-End Readout Electronics
… spectroscopy (PHS) measurements with 0.1 μCi 241Am source. Charge collection efficiency was investigated using a drift-diffusion charge transport model. The energy resolution for 5.486 MeV alpha particles was 166 keV with charge collection efficiency of 22.6%. Electronic noise analysis of …
-
Alpha-event characterization for germanium detectors
… identify such events and thus eliminate them as sources of background. An especially designed segmented true-coaxial detector was probed with alpha particles from an 241Am source inside the test-stand GALATEA, located at the MPI f¨ur Physik in Munich. Pulse shape analysis was performed to …
-
Pre-clinical evaluation of lethal and sublethal DNA damage in human cell cultures by ultrashort pulse and ultra-high dose rate laser accelerated protons
… (low LET radiation) and α-particles from 5.5 MeV 241Am source, available in PGJCCR (Queen’s University Belfast, Belfast, UK).
-
Tools for the Advancement of Radiopharmaceutical Therapy
… vivo experiments with radiopharmaceuticals and sources of ionizing radiation are performed to increase radiobiological knowledge, which is helpful in the optimization of radiopharmaceutical therapy. Dosimetry is also necessary for these studies to correctly quantify the biological response to …
-
Defect Characterization of 4H-SIC by Deep Level Transient Spectroscopy (DLTS) and Influence of Defects on Device Performance
… the detector irradiated with a standard 0.1 μCi 241Am source. The charge transport and collection efficiency results, obtained from the alpha particle pulse-height spectroscopy, were interpreted using a drift-diffusion charge transport model. The detector performances were evaluated in terms of …
-
UCN Detector development for the TRIUMF Neutron EDM experiment
… being developed at TRIUMF, where a high density source of ultra cold neutrons (UCN) is currently under construction. A fast, high-efficiency UCN detector is needed for the experiment, and a 6-Li doped glass scintillation detector is being explored for this purpose. In this work, simulations and …