Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 33 for “"3.0 T"”.

  1. Simultaneous Intracranial EEG-fMRI for the Study of Epilepsy in Humans at 3.0 T

    Neuroimaging plays in an important role in the diagnosis and treatment of epilepsy. In this work, a novel multi-modal technique for imaging the hemodynamic correlates of epileptic activity is explored. Simultaneous intracranial electroencephalography functional magnetic resonance imaging …

    calgary Repository record for Simultaneous Intracranial EEG-fMRI for the Study of Epilepsy in Humans at 3.0 T (opens in a new tab)

  2. MR Safety of Implantable Medical Devices: In Silico Assessment Using Computational Human Models in 1.5 T and 3.0 T Conventional MRI Systems, and Analysis in Open-bore MRI at 1.2 T

    Magnetic Resonance Imaging (MRI) is one of the most widely used diagnostic tools in medicine. The demand for MRI scans is steadily increasing due to the rising prevalence of joint replacements, cardiac devices, and MRI-requiring conditions such as neurodegenerative disorders, cancers, and …

    houston Repository record for MR Safety of Implantable Medical Devices: In Silico Assessment Using Computational Human Models in 1.5 T and 3.0 T Conventional MRI Systems, and Analysis in Open-bore MRI at 1.2 T (opens in a new tab) Embargoed until 2028-05-01

  3. Kardiovaskuläre MRT bei 1.5 und 3.0 Tesla unter Verwendung von dynamischen SSFP- und statischen "Black-Blood"-Sequenzen, mit und ohne den Einsatz paralleler Bildgebungstechniken

    Die kardiale MRT erfordert eine hohe räumliche und zeitliche Auflösung bei möglichst kurzer Messzeit. Aufgrund physiologischer Limitationen seitens des Patienten ist die Nutzung immer schnellerer und stärkerer Gradientensysteme limitiert. Die Hochfeld-MRT bei 3.0 T und der Einsatz paralleler …

    fu-berlin Repository record for Kardiovaskuläre MRT bei 1.5 und 3.0 Tesla unter Verwendung von dynamischen SSFP- und statischen "Black-Blood"-Sequenzen, mit und ohne den Einsatz paralleler Bildgebungstechniken (opens in a new tab)

  4. Quantitative Analyse der Diffusions-Tensor-Bildqualität (DTI) unter Verwendung von paralleler Bildgebung in der Hochfeld-MRT bei 1,5 und 3 Tesla

    Das Ziel unserer Studie war die Entwicklung eines methodischen Ansatzes zur quantitativen Evaluierung und Analyse der Bildqualität diagnostischer Diffusions-Tensor-Bildgebung (DTI) unter Verwendung paralleler Bildgebung (PAT) bei 1.5 T und 3.0 T MR-Tomographen. Im Rahmen einer prospektiven Studie …

    lmu-germany Repository record for Quantitative Analyse der Diffusions-Tensor-Bildqualität (DTI) unter Verwendung von paralleler Bildgebung in der Hochfeld-MRT bei 1,5 und 3 Tesla (opens in a new tab)

  5. VALIDATION, OPTIMIZATION, AND IMAGE PROCESSING OF SPIRAL CINE DENSE MAGNETIC RESONANCE IMAGING FOR THE QUANTIFICATION OF LEFT AND RIGHT VENTRICULAR MECHANICS

    Recent evidence suggests that cardiac mechanics (e.g. cardiac strains) are better measures of heart function compared to common clinical metrics like ejection fraction. However, commonly-used parameters of cardiac mechanics remain limited to just a few measurements averaged over the whole left …

    uky-thes Repository record for VALIDATION, OPTIMIZATION, AND IMAGE PROCESSING OF SPIRAL CINE DENSE MAGNETIC RESONANCE IMAGING FOR THE QUANTIFICATION OF LEFT AND RIGHT VENTRICULAR MECHANICS (opens in a new tab)

  6. Myelin water imaging : development at 3.0T, application to the study of multiple sclerosis, and comparison to diffusion tensor imaging

    T2 relaxation imaging can be used to measure signal from water trapped between myelin bilayers; the ratio of myelin water signal to total water is termed the myelin water fraction (MWF). First, results from multi-component T2 relaxation and diffusion tensor imaging (DTI) were compared for 19 …

    ubc Repository record for Myelin water imaging : development at 3.0T, application to the study of multiple sclerosis, and comparison to diffusion tensor imaging (opens in a new tab) Download PDF for Myelin water imaging : development at 3.0T, application to the study of multiple sclerosis, and comparison to diffusion tensor imaging (opens in a new tab)

  7. A novel method for detecting and recording movement and functional performance of cardiac valve prostheses exposed to the static magnetic field associated with magnetic resonance imaging

    Aging and disease processes are known to compromise tissue strength and consequently increase the risk of harmful movement or detachment of a heart valve prosthesis in vivo when exposed to strong magnetic forces associated with magnetic resonance imaging (MRI). Research however, has failed to fully …

    strathclyde Repository record for A novel method for detecting and recording movement and functional performance of cardiac valve prostheses exposed to the static magnetic field associated with magnetic resonance imaging (opens in a new tab)

  8. Adaptive receiver arrays for magnetic resonance imaging

    In den letzten zwanzig Jahren hat sich die Magnetresonanztomographie (MRT) zu einer der wichtigsten und vielseitigsten klinischen Untersuchungsmethoden entwickelt, da sich mit ihrer Hilfe nichtinvasiv unterschiedliche Arten von Informationen aus dem Inneren des menschlichen Körpers mit hoher …

    zurich Repository record for Adaptive receiver arrays for magnetic resonance imaging (opens in a new tab) Restricted access

  9. Characterizing magnetization exchange in healthy human brain and bovine brain

    Multi component T₂ relaxation imaging is an established MRI technique for measuring myelin water (MW, water molecules trapped between myelin sheath bilayers). Myelin water fraction (MWF, the fraction of central nervous system water with a short T₂) has been quantitatively correlated to histological …

    ubc Repository record for Characterizing magnetization exchange in healthy human brain and bovine brain (opens in a new tab) Download PDF for Characterizing magnetization exchange in healthy human brain and bovine brain (opens in a new tab)

  10. Inter- and Intrafraction Motion Management for MR guided Proton Therapy of Pancreatic Carcinoma

    Hintergrund: Patienten mit Bauchspeicheldrüsenkrebs könnten von der Protonentherapie (PT) profitieren, aufgrund ihres Potentials der Schonung von Risikoorganen. Jedoch führen die inter- und intrafraktionelle Beweglichkeit der Bauchspeicheldrüse zu hohen Unsicherheiten bei der Dosisapplikation und …

    qucosa-diss

  11. NOVEL MRI APPROACHES FOR QUANTITATIVE ASSESSMENT OF CORONARY ARTERIES AND VENTRICULAR FUNCTION

    Despite advances in screening techniques and prevention guidelines, cardiovascular disease remains the leading non-communicable disease with 17 million deaths worldwide in 2008. Approximately 6% of American adults had a history of coronary artery disease in 2010, and there were more than 700,000 …

    jhu Repository record for NOVEL MRI APPROACHES FOR QUANTITATIVE ASSESSMENT OF CORONARY ARTERIES AND VENTRICULAR FUNCTION (opens in a new tab)

  12. Assessing Recovery of Mild Traumatic Brain Injury Patients Using Diffusion Tensor Imaging

    In this study we investigated whether Diffusion Tensor Imaging (DTI) could be used to assess recovery in patients with mild traumatic brain injury (mTBI). Thirteen acute mTBI patients 18-50 years of age and seven age- and sex-matched controls with no head injury were recruited from the emergency …

    houston Repository record for Assessing Recovery of Mild Traumatic Brain Injury Patients Using Diffusion Tensor Imaging (opens in a new tab)

  13. Observer Reliability of Cephalometric Landmark Identification on 3-D MR Images

    Introduction: Cephalometric analysis is a cornerstone of orthodontic diagnosis, yet much information is lost when 3-dimensional structures are assessed with 2-dimensional methods. CBCT offers 3-dimensional imaging but at the cost of higher levels of ionizing radiation. Magnetic resonance imaging …

    loma-linda Repository record for Observer Reliability of Cephalometric Landmark Identification on 3-D MR Images (opens in a new tab)

  14. Applications of magnetic resonance encephalography-spin-echo and multi-echo fMRI

    Functional Magnetic Resonance Imaging (fMRI) based on the blood oxygenation level dependent (BOLD) effect has become a useful tool to study the functional connectivity of the human brain. However, conventional gradient-echo (GE) BOLD fMRI faces challenges like signal loss in areas with strong …

    freiburg-diss Repository record for Applications of magnetic resonance encephalography-spin-echo and multi-echo fMRI (opens in a new tab)

  15. Geometric Variances in Hip Osteoarthritis and Tribology of the Natural Hip

    Osteoarthritis (OA) of the hip joint is a common form of arthritis that often requires surgical intervention using total hip replacement (THR), as treatment using early interventional techniques is still poorly understood. It is hoped that gaining a better understanding of hip geometry, and that …

    whiterose Download PDF for Geometric Variances in Hip Osteoarthritis and Tribology of the Natural Hip (opens in a new tab)

  16. Investigating the myelin water fraction as a function of TR and the intra/extra cellular water geometric mean T2 as a function of refocusing interval

    In this thesis two studies were done using MRI. In chapter two, in vivo 3.0 T MRI data from white matter and grey matter in brain from 4 healthy volunteers was studied using a multi component T₂ relaxation analysis. The goal of this study was to find the dependence of myelin water fraction (MWF), …

    ubc Repository record for Investigating the myelin water fraction as a function of TR and the intra/extra cellular water geometric mean T2 as a function of refocusing interval (opens in a new tab) Download PDF for Investigating the myelin water fraction as a function of TR and the intra/extra cellular water geometric mean T2 as a function of refocusing interval (opens in a new tab)

  17. Manganese-Enhanced Magnetic Resonance Imaging of Breast Cancer Cells

    Magnetic resonance imaging (MRI) is utilized in the detection of abnormalities and diseases such as cancer. MRI contrast agents (CAs) are routinely used in cancer imaging to provide enhanced diagnosis. There has been continued interest in engineering CAs and evaluating their diagnostic efficacy to …

    toronto-retro Repository record for Manganese-Enhanced Magnetic Resonance Imaging of Breast Cancer Cells (opens in a new tab)

Page 1 of 2