Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 27 for “"300 kV"”.
-
Model zkušebního zdroje 300 kV
… střídavého testovacího systému s napětím 300 kV, umístěného ve Vědecko-technologickém parku profesora Lista. Práce se zaměřuje na popis konstrukce tohoto systému, jeho funkční parametry a použití v praxi pro různé typy vysokonapěťových zkoušek. Klíčovým aspektem analýzy je hodnocení …
-
Development of a 300 KV DC High Voltage Photogun and Beam Based Studies of Alkali Antimonide Photocathodes
… was designed, built, and operated reliably at - 300 kV bias voltage using alkali-antimonide photocathodes. This photogun will provide a magnetized electron beam for the future Jefferson Lab Electron-Ion Collider (JLEIC) cooler. This research describes key electrostatic design features of the …
-
Kilo-Voltage X-Ray Correction Factors for In-Water Measurements Based on TG-61
For x-ray tube potentials 100 kV, the AAPM TG-61 protocol for 40-300 kV x-ray beam dosimetry in radiotherapy recommends an in-water measurement which is based on ionization chambers calibrated in air in terms of air kerma. The variation of the overall correction factor (PQ;cham) and its components …
-
Transmission Electron Microscopy of Organic Crystalline Material and Zeolites
… irradiated by a high-energy electron beam (80 – 300 kV). Transmission electron microscope diffraction pattern analysis was used to determine the lifetime of theophylline form II under a number of controlled microscope and specimen conditions. Values of the characteristic electron fluence for …
-
Low-Dose STEM Characterisation of Nanoscale Calcium Carbonate Particles
… threshold for the loss of lattice integrity at 300 kV in CTEM was determined to be 2.7x107 e-nm-2. Microscope operating conditions were optimised to maximise the extracted analytical information, whilst minimising the extent of electron beam damage. It is shown that STEM offers significant …
-
Nelineární zobrazení v 100 keV transmisním elektronovém mikroskopu
… daty při urychlovacích napětí 100, 200 a 300 kV. Vliv jednotlivých nelineárních členů na pozorované rozlišení je diskutován.
-
High-Yield Wafer-Scale Self-Assembly of 3D Microelectronic Devices for Electron Optics
… deflection in the mrad regime was observed for 300 kV electrons. In addition, 2D deflectors for the electron beam were fabricated to allow blanking, 2D scanning and a proof of concept for stroboscopic experiments. Useful electron beam deflection was observed up to a frequency of 100 MHz. The …
-
Miniaturized Electron Optics based on Self-Assembled Micro Coils
… besitzen eine Ablenkleistung im mrad-Bereich für 300 kV Elektronen und einen Frequenzdurchgang bis zu 100 MHz. Darüber hinaus wurden miniaturisierte adrupollinsen mit Brennweiten kleiner als 46 mm für 300 kV Elektronen entwickelt. Diese drei Arten elektronenoptischer Elemente sind von großem …
-
High field Stark effects in diatomic hydrides
… was used to apply electric fields of more than 300 kV/cm to water vapor, a mixture of cyanogen and hydrogen, and ammonia, permitting the observation of Stark effects in the optical spectra of the OK, CH, and NH molecules, respectively. These experiments yielded the following values of the …
-
Pulse Sharpening Circuit for Explosive Emission Cathode Driver
… self-breakdown switch designed to operate up to -300 kV. This unit is intended to reduce the rise-time of a 4-stage Type-E PFN Marx Generator that will be used to study operational characteristics of velvet cathodes. Simulations of the peaking circuit show a reduction in voltage rise-time from …
-
Exploding wires in the metal-nonmetal transition regime
… 40 kA of current in 100 ns, generating nearly 300 kV into a high impedance 20 $\Omega$ load, switching in excess of 1 kJ of electrically stored energy. Additionally, exploding wires have further application to applied engineering as intense shockwave sources which can be used for a variety of …
-
Measurements of Continuous X-Ray Spectra with a Scintillation Spectrometer
… x-ray unit operating at 100, 150, 200, 250, and 300 kV. An attempt was made to measure the absolute intensity as well as the spectral distribution. In order to reduce the counting rate to a measureable level, it was necessary to place the thallium-activated sodium-iodide detector 50 meters from …
-
Design and experimental study of a dual vircator microwave source
… of 20 ns. The capacitor bank is charged to 30 kV by a bank of power supplies. A 1:10 pulse transformer charges the water line to 300 kV in approximately 2.5 [mu]s. The output pulse from the water line is stepped up to 250 kV by an inductive adder. This signal is utilized to simultaneously drive …
-
Η ΣΗΜΑΣΙΑ ΤΩΝ ΑΚΤΙΝΩΝ ΕΙΣ ΤΗΝ ΘΕΡΑΠΕΙΑΝ ΤΗΣ ΜΕΓΑΛΑΚΡΙΑΣ.
… CONSISTED OF EXTERNAL RADIATION OF 220 - 300 KV GIVEN BY A CONVENTIONAL X-RAY MACHINE. THREE PORTALS WERE USED(2 TEMPORAL 4X4 CM OR 4X5 CM AND ONE FRONTAL). THE TUMOUR DOSE RANGED BETWEEN 4200 R - 4800 R GIVEN IN 48 - 52 DAY - TIME INTERVALS. THE ESTIMATION OF OUR THERAPEUTIC RESULTS WAS …
-
Improved contact design for the SiC photo-switch used in high power applications
… Carbide (SiC) has a bulk dielectric strength of 3000 kV/cm, thermal conductivity of 4.9 W/(cm-K), and high tensile strength. It is considered the most promising photo-switching material that can enable the fielding of the most compact pulse power systems. The SiC photoswitch as an advantage over …
-
Dynamic environmental transmission electron microscopy
… methods. To develop the DETEM the Hitachi H-9500 300 kV TEM installed at the Frederick Seitz Materials Research Laboratory, has been modified to accommodate the optics to allow various pump-probe methods to take place for in-situ experiments. The design and assembly of the pump and probe optical …
-
Non-explosive test bed for flux compression generator fuses
… with a non-optimized fuse has produced ~ 100 kV into a 15 §Ù load, which leads into a regime relevant for High Power Microwave (HPM) systems. It is expected that ~ 300 kV can be achieved with the present two-stage HFCG driving an inductive storage system with an electro-exploding fuse. In …
-
Micro-Structure of Functional Particles and Particle Systems
… Beam sensitivity of AG is investigated with 80 kV and 300 kV EELS. The quantitative EELS result shows an increased π*/ σ* peak ratio of the carbon K-edge when lowering the acceleration voltage of TEM, which indicates the 300 kV electron beam modifies the graphitic carbon into the amorphous …
-
Space Charge Effects in Low Energy Magnetized Electron Beams
… Accelerator Facility (JLab) using a compact, 300 kV DC high voltage photo-gun with an inverted insulator geometry and bi-alkali antimonide photocathode. The beam magnetization was characterized using a modest diagnostic beamline to measure beam sizes, rotation angles, and normalized transverse …
Page 1 of 2