Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 15 of 15 for “"363.15"”

  1. Phase equilibrium measurements at low-to-moderate pressures for systems containing n-Hexane, 1-Hexene and n-Methyl-2-pyrrolidone.

    … kPa, as well as the system of 1-hexene + NMP at 363.15 K and n-hexane + NMP at 363.15 K. Published literature data for these test systems were employed to verify the measured data for the test systems complied with thermodynamic consistency. All other data constitutes new data, currently …

    ukzn Repository record for Phase equilibrium measurements at low-to-moderate pressures for systems containing n-Hexane, 1-Hexene and n-Methyl-2-pyrrolidone. (opens in a new tab)

  2. Standard Partial Molar Heat Capacities and Volumes of Aqueous Dimethylethanolamine and 3-Methoxypropylamine from 283 to 393 K, and Thermodynamic Functions for Their Ionization Equilibria to 598 K and 20 MPa

    … salts were measured relative to water at 283.15 K ≤ T ≤ 363.15 K and 0.1 MPa using vibrating tube densimeters. Volumetric heat capacities of the same solutions were measured at 283.15 K ≤ T ≤ 393.15 K and 0.4 MPa using twin fixed-cell, power compensation, differential temperature scanning nano …

    guelph Repository record for Standard Partial Molar Heat Capacities and Volumes of Aqueous Dimethylethanolamine and 3-Methoxypropylamine from 283 to 393 K, and Thermodynamic Functions for Their Ionization Equilibria to 598 K and 20 MPa (opens in a new tab)

  3. Thermochemical Properties of Model Amines under Hydrothermal Conditions from Densimetry and Fixed-Cell Scanning Nano Calorimetry Measurements

    … were measured relative to water at 283.15 K ≤ T ≤ 363.15 K and 0.1 MPa using vibrating tube densimeters. Volumetric heat capacities of the same solutions were measured at 283.15 K ≤ T ≤ 393.15 K and 0.4 MPa using twin fixed-cell, power compensation, differential temperature scanning nano …

    guelph Repository record for Thermochemical Properties of Model Amines under Hydrothermal Conditions from Densimetry and Fixed-Cell Scanning Nano Calorimetry Measurements (opens in a new tab) Embargoed until 2027-09-02

  4. Automation of a static-synthetic apparatus for vapour-liquid equilibrium measurement.

    … the water (1) + propan-1-ol (2) system at 313.15 K and the n-hexane (1) + butan- 2-ol system at 329.15 K. Phase equilibrium data of binary systems, containing the solvent morpholine-4-carbaldehyde (NFM) was then measured. The availability of vapour-liquid equilibrium data for binary systems …

    ukzn Repository record for Automation of a static-synthetic apparatus for vapour-liquid equilibrium measurement. (opens in a new tab)

  5. An investigation into the potential of NFM, DEG and TEG as replacement solvents for NMP in separation processes.

    … aromatics; were measured at temperatures of 333.15, 348.15 and 363.15 K. The γ∞ measurements in N-formylmorpholine were used to verify this experimental set up and technique. Once the experimental set up had been proven, γ∞ in N-methylpyrrolidone, triethylene glycol and diethylene glycol were …

    ukzn Repository record for An investigation into the potential of NFM, DEG and TEG as replacement solvents for NMP in separation processes. (opens in a new tab)

  6. Vapour-liquid equilibrium measurements at moderate pressures using a semi-automatic glass recirculating still.

    … measurements were ±0.005 kPa, ±0.013kPa and ±0.15kPa for the 0-10 kPa, 10-100 kPa and 100-500 kPa pressure ranges respectively. A combined standard uncertainty in temperature of ±0.02 K was calculated. The published data of Joseph et al., (2001) and Gmehling et al,. (1995) for the cyclohexane …

    ukzn Repository record for Vapour-liquid equilibrium measurements at moderate pressures using a semi-automatic glass recirculating still. (opens in a new tab)

  7. Dados experimentais e método computacional para a determinação da composição no processo de regeneração de monoetileno glicol

    … points) measurements were performed from 278.15 to 363.15 K, the complete concentration range of solvents, and NaCl up to almost saturation. The solution theory was applied for density modeling purpose, using the excess volume (V E ). The V E was correlated with the aid of the Redlich–Kister …

    brazil-ufrn Repository record for Dados experimentais e método computacional para a determinação da composição no processo de regeneração de monoetileno glicol (opens in a new tab)

  8. Thermo-physical properties and activity coefficients at infinite dilution for ionic liquid systems at several temperatures

    … + acetonitrile} at different temperatures (293.15, 298.15, 303.15, 308.15 and 313.15) K and at a pressure of 0.1 MPa with aid of the experimental density (ρ), speed of sound (u) data. The calculated data were correlated by using the Cibulka equation with the help of Redlich–Kister parameters …

    dut Repository record for Thermo-physical properties and activity coefficients at infinite dilution for ionic liquid systems at several temperatures (opens in a new tab)

  9. Separation of binary homogeneous azeotropic mixtures using pervaporation.

    … pressure (2‒5 kPa), feed temperature (338.15‒348.15 K) and feed water concentration (1‒5 wt.%) are reported in terms of flux and permeate quality. Results confirmed that pervaporation is a suitable method to break an azeotrope. Due to technical issues encountered with the equipment, the …

    ukzn Repository record for Separation of binary homogeneous azeotropic mixtures using pervaporation. (opens in a new tab)

  10. Robust equipment for the measurement of vapour-liquid equilibrium at high temperatures and high pressures.

    … and acetonitrile (1) + N-methylformamide (2), at 363.15 K using the equipment of Rarey and Gmehling (1993). The systems CO2 (1) + Napthalene (2) at T = 372.45 K, 403.85 K and 430.65 K and CO2 (1) + Benzoic acid (2) at T= 403.28 K, 432.62 K and 458.37 K were measured on the equipment of Kolbe and …

    ukzn Repository record for Robust equipment for the measurement of vapour-liquid equilibrium at high temperatures and high pressures. (opens in a new tab)

  11. Binary vapour-liquid equilibrium for systems of industrial importance.

    … (1) + 4-methyl-2-pentanone (2) (at 338.15 K, 353.15 K, and 368.15 K), 2-propanol (1) + 4-methyl-2-pentanone (2) (at 323.15 K, 338.15 K, and 353.15 K) and 2-pentanone (1) + 2-methylpropan-1-ol (2) (at 343.15 K, 358.15 K, and 363.15 K). A modified (Bhownath, 2008) low pressure dynamic VLE …

    ukzn Repository record for Binary vapour-liquid equilibrium for systems of industrial importance. (opens in a new tab)

  12. Carbon dioxide capture methods for industrial sources.

    … were conducted under system pressures of 5 to 15 bar and temperatures of 363.15 and 413.15 K, using a static analytic apparatus. CO2 liquid loading results were analysed and discussed. The experimental data were regressed in Matlab (R2009b) using the Posey-Tapperson-Rochelle model and the …

    ukzn Repository record for Carbon dioxide capture methods for industrial sources. (opens in a new tab)

  13. Analyse transverse de risques en radiothérapie : modélisation et évaluation des barrières et des facteurs techniques, humains et organisationnels à l’aide de Réseaux bayésiens

    La radiothérapie est une ressource incontestée dans l'arsenal de traitement du cancer. De par sa spécificité, elle induit des risques pour les patients et pour les professionnels de santé qui imposent qu'elle soit opérée dans un environnement et un cadre maîtrisé et contrôlé. Cependant, de par la …

    star-france Repository record for Analyse transverse de risques en radiothérapie : modélisation et évaluation des barrières et des facteurs techniques, humains et organisationnels à l’aide de Réseaux bayésiens (opens in a new tab)

  14. Experimental study and thermodynamic modelling of mixtures containing third generation ionic liquids and deep eutectic solvents

    … were conducted at the temperature range of 293.15 to 363.15 K and at atmospheric pressure for the pure solvents studied. 2HEAF was found to be the densest solvent, while the two structural isomers ChCl:1,4 butanediol (1:4) and ChCl:1,2 butanediol (1:4) presented the lowest density values. An …

    greece Repository record for Experimental study and thermodynamic modelling of mixtures containing third generation ionic liquids and deep eutectic solvents (opens in a new tab)