Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 38 for “"3D Dose"”.
-
Direct optimization of 3D dose distributions using collimator rotation
… plan without compromising the quality of the dose distribution. It is also shown that an arrangement of equispaced collimator angles takes full advantage of the flexibility associated with collimator rotation. A study including ten recurring nasopharynx cancer patients is used to evaluate the …
-
A Novel 3D Dose Detector Using A Plastic Scintillator and MV Image Reconstruction
… linear accelerator (LINAC) to deliver complex dose distributions to a defined target while simultaneously sparing surrounding organs at risk (OARs) and adjacent tissue. Dose calculation algorithms used in treatment planning for these customized distributions generally have high accuracy, but …
-
Evaluation of Presage® As A 3D Dose Verification to ol In Proton Beams
… techniques have advanced and radiation dose plans have become much more complex over the last decade. This is especially true in proton therapy, which involves extremely steep dose gradients as a result of positioning the Bragg peak to cover the volumes to be treated. The Bragg peak can …
-
Verification of the delivered patient radiation dose for non-coplanar beam therapy
… North America. Its purpose is to deliver a high dose of radiation to the tumor while limiting doses to surrounding normal tissues. This is a challenging task when organs-at-risk (OARs) are in close proximity to the tumor. This is why recently many researchers have investigated the opportunity of …
-
Multi-layer Strip Ionization Chamber for Proton Quality Assurance and Imaging
… is needed to verify the quality of treatment dose delivery. Current clinical practice employs films or a two-dimensional (2D) detector to measure the dose at one or a few arbitrarily selected depths, which is insensitive to delivery error and time-consuming. A 3D dosimeter that can measure the …
-
Beam monitoring and dosimetry for ultra-high dose rate radiobiology at laser-driven proton sources
Ultra-high dose rate proton radiation has the potential to improve cancer treatment by reducing the normal tissue complication probability and, at the same time, reaching the tumor control probability known from conventional photon radiation therapy. Here, the ultra-high dose rate leads to normal …
-
Development and Validation of Advanced Techniques for Treatment Planning and Verification in Megavoltage Radiotherapy
… great need for assuring quality of the radiation dose distributions generated by the advanced intensity modulated treatments (IMRT/VMAT). This is typically accomplished by the assessment of the treatment plan quality at the planning stage and then verification of the dose distributions through …
-
Optimization of Radiation Therapy in Time-Dependent Anatomy
… (4D) anatomy. Specifically, this study examines dose estimation, dose evaluation, and decision making in the context of optimizing lung cancer radiation therapy. Two methods of dose estimation are compared in patients with locally advanced and early stage lung cancer: dose computed on a single …
-
Evaluation of Presage® Dosimeters For Brachytherapy Sources and The 3D Dosimetry and Characterization of The New Agx100 125I Seed Model
… source designs and techniques, method of 3D dosimetry for treatment dose verifications would better ensure accurate patient radiotherapy treatment. This study was aimed to first evaluate the 3D dose distributions of the low-dose rate (LDR) Amersham 6711 OncoseedTM using PRESAGE® dosimeters …
-
Three-dimensional dosimetry around small distributed high-Z materials
… irradiated by low energy beams where the dose enhancement is large. In the majority of the cases, they used one or two dimensional detectors. Therapeutic beams, however, are mostly 6 MV and higher with significantly less dose enhancement. Over the last decade, significant improvements in …
-
Treatment Planning Automation For Rectal Cancer Radiotherapy
… two common existing treatment techniques, 3DCRT and VMAT, for rectal cancers, and then explored an alternative method for creating a treatment plan using deep learning. Methods: To automate the 3DCRT treatment technique, we used deep learning to predict the shapes of field apertures for …
-
Analysis of Radiation Therapy in Cancer Treatment using Machine Learning
… and the relationship between the radiation dose distribution and breast size for whole-breast radiotherapy were investigated using statistical and machine learning methods. Two PRO measures; the M.D. Anderson symptom inventory for head and neck cancer, and the M.D. Anderson dysphagia …
-
Polymer Gel Dosimetry in Magnetic Resonance-Image Guided Radiation Therapy
… treatment plan and consequently a better dose delivery to the tumor. The need for MR-IGRT treatment plan verification with 3D dosimeters arose due to the presence of the strong magnetic field altering dose depositions in 3D. Furthermore, vendors only provide MR-compatible electronics that …
-
Evaluation of a Helical Diode Array and Planned Dose Perturbation Model for Pretreatment Verification of Volumetric Modulated Arc Therapy
… array of silicon diode detectors to measure dose in a cylindrical plane. 3DVH is an associated software that can use ArcCHECK diode measurements along with treatment planning system (TPS) data to guide a full 3D dose reconstruction. The ArcCHECK phantom, along with 3DVH software was evaluated …
-
Cone Beam Optical Computed Tomography-Based Gel Dosimetry
The complex dose distributions delivered by modern, conformal radiation therapy techniques present a considerable challenge in dose verification. Traditional measurement tools are difficult and laborious to use, since complete verification requires that the doses be determined in three dimensions …
-
Four-Dimensional In Vivo Dosimetry By Dose Reconstruction Using Continuous Epid Images And Phase Sorting Method
… dosimetry is widely used for patient specific dose evaluation and treatment verification in external beam radiation therapy (EBRT). There is a growing interest in using an electronic portal imaging device (EPID) for in vivo dosimetry, by correlating pixel values of measured EPID images to …
-
Towards EPID-based 3D in vivo dosimetry for modern radiation therapy
… Arc Therapy (VMAT), can deliver highly conformal dose distributions, with steep dose gradients between the target and organs at risk. This increases the demands on proper quality assurance and dose verification before (pre-treatment) and during (in vivo) patient irradiation. This project proposes …
-
Development of a Knowledge-based Planning Pipeline for Gamma Knife Radiosurgery
… manually configure shots to create a desired dose distribution, or inverse planning, where dose distributions are optimized based on multiple clinical objectives. However, both approaches are limited by their reliance on planner experience, in addition to several other drawbacks. To improve …
-
Secondary Monitor Unit Checks for VMAT Using Parallelized Monte Carlo Simulations
… verification of VMAT treatment planning system dose calculations, that would be in accordance with TG-114 recommendations. Methods: For a VMAT patient treatment plan created for a Varian Trilogy linac, DICOM information was exported from Eclipse. An open-source platform was used to generate …
-
Combining Monte Carlo simulations and detector measurements for a novel quality assurance system of assembled brachytherapy eye plaques.
… with an acrylic plaque holder to record the 2D dose distribution of the plaque perpendicular to the plaque central axis. The system is simulated in Monte Carlo to generate a 3D dose distribution. Calibrating the detector relative to the Monte Carlo results allows comparisons between simulated …
Page 1 of 2