Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"3D Mode"”.

  1. Elevation Effects on GPS Positional Accuracy

    … the collection of data with four satellites (3D mode), yet field data conditions are often less than ideal. Four satellites may not always be in view because of mountainous topography, heavy forest cover, or other obstructions which block satellite signals from the receiver. This study …

    vt Repository record for Elevation Effects on GPS Positional Accuracy (opens in a new tab)

  2. Integrating Bridge Information Modeling (BRIM), Bridge Sustainability Rating System (BRSRS), Bridge Environmental Performance Strategy Mapping (BREPSM) and Cost Estimating At the Conceptual Design Stage

    … development as cities rely heavily on various modes of transportation for access and mobility. In an effort to fill the gap in the knowledge and methodology used in the construction of sustainable bridges, a model is developed using the concept of BrIM having the capabilities to develop bridges …

    ottawa-retro Repository record for Integrating Bridge Information Modeling (BRIM), Bridge Sustainability Rating System (BRSRS), Bridge Environmental Performance Strategy Mapping (BREPSM) and Cost Estimating At the Conceptual Design Stage (opens in a new tab)

  3. Integrating 3D-CAD and Cost Estimating at the Conceptual Design Stage of Bridge Project

    Bridge Information Modeling (BrIM), as a concept, has been introduced to enhance the procedures of the whole phases of a bridge life-cycle starting with concept and design, through construction and operation, and ending with maintenance and rehabilitation. Integrating BrIM and design tools will …

    ottawa-retro Repository record for Integrating 3D-CAD and Cost Estimating at the Conceptual Design Stage of Bridge Project (opens in a new tab)

  4. E-invigilation Of E-assessments

    … being able to provide invigilation in a remote-mode has restricted the types of assessments, with exams or in-class test assessments proving difficult to validate. Students are still required to attend physical testing centres in order to ensure strict examination conditions are applied. Whilst …

    plymouth Repository record for E-invigilation Of E-assessments (opens in a new tab)

  5. An investigation into the use of scattered photons to improve 2D Position Emission Tomography (PET) functional imaging quality

    … This is more serious for a scanner operated in 3D mode or with large patients, where the scatter fraction can be as high as 40-60%. When one or both photons are scattered, the line of response (LOR) defined by connecting the two relevant detectors no longer passes through the annihilation …

    manitoba Repository record for An investigation into the use of scattered photons to improve 2D Position Emission Tomography (PET) functional imaging quality (opens in a new tab)

  6. Magnetic vortex dynamics: non-linear dynamics, pinning mechanisms, and dimensionality crossover.

    … from two-dimensional (2D) to three-dimensional (3D) with increasing disk thickness. A 2D mode of the vortex dynamics is the lowest frequency excitation below the crossover region, above which a 3D mode becomes the lowest frequency excitation.

    umn Repository record for Magnetic vortex dynamics: non-linear dynamics, pinning mechanisms, and dimensionality crossover. (opens in a new tab)

  7. Strong optical coupling between 3D confined resonant modes in microtube cavities

    Coupled whispering-gallery-mode (WGM) optical microcavities have been extensively explored to tune the resonant eigenfrequencies and spatial distributions of the optical modes, finding many unique photonic applications in a variety of fields, such as nonlinear optics, laser physics, and …

    qucosa-diss

  8. Developing a 3D Visualisation System for Medical Imaging and Applying it in Education, Diagnosis and Surgery

    … to address these needs, offering interactive 3D visualisation tools that integrate volumetric medical data, such as magnetic resonance imaging (MRI) and computed tomography (CT) scans. VAH also explored advanced display technologies, including stereoscopic and autostereoscopic (AS) displays, …

    kings Repository record for Developing a 3D Visualisation System for Medical Imaging and Applying it in Education, Diagnosis and Surgery (opens in a new tab) Download PDF for Developing a 3D Visualisation System for Medical Imaging and Applying it in Education, Diagnosis and Surgery (opens in a new tab)

  9. Βιοχημικός και δομικός χαρακτηρισμός του τμήματος TPR επαναλήψεων του μεταγραφικού παράγοντα Ssn6 του Saccharomyces cerevisiae

    … (aa: 1-72) of Tup1 to form the complex. Using 3D-mode¬ling and mutagenesis data, our group has previously shown that the structural integrity of TPR 1 and its cor¬rect positioning relatively to TPR 2 are crucial for Tup1 binding. In the present study we investigate the structural stability of …

    greece Repository record for Βιοχημικός και δομικός χαρακτηρισμός του τμήματος TPR επαναλήψεων του μεταγραφικού παράγοντα Ssn6 του Saccharomyces cerevisiae (opens in a new tab)

  10. Grounding grid design for high voltage substations : an assessment of effectiveness for lightning currents

    … actual grounding systems or on laboratory scaled models. Although experiments can provide insights of the actual grounding operation, the shortcoming is that a large area of lab space is required which reflects into high costs. As an alternative, computer simulation has been introduced, and can be …

    strathclyde Repository record for Grounding grid design for high voltage substations : an assessment of effectiveness for lightning currents (opens in a new tab)

  11. Wide field x-ray spectral imaging using bent Laue monochromators

    … either projection (2D) or computed tomography (3D) mode of operation. This software is made available at the Canadian Light Source BMIT-BM beamline and is compatible with another contrast element imaging method - spectral K-edge subtraction imaging. The energy resolution of a bent crystal at the …

    sask Repository record for Wide field x-ray spectral imaging using bent Laue monochromators (opens in a new tab)

  12. Investigating the Potential Impact of Wind Farms on Lake Erie

    … COHERENS (a Coupled Hydrodynamical-Ecological model for Regional and Shelf Seas) numerical software for the simulations. They were applied in 1 and 3 dimensions. In both cases, we used real wind speed and other meteorological data including atmospheric pressure, air temperature, humidity and …

    york Repository record for Investigating the Potential Impact of Wind Farms on Lake Erie (opens in a new tab)

  13. Simulation of image formation in nuclear medicine imaging systems using Monte Carlo methods

    … (PET) scanners with Monte-Carlo (MC) methods. Α model was developed using the Monte Carlo package of Geant4 Application for Tomographic Emission (GATE) and the software for tomographic image reconstruction (STIR) with cluster computing to obtain reconstructed images. The PET scanner used in this …

    greece Repository record for Simulation of image formation in nuclear medicine imaging systems using Monte Carlo methods (opens in a new tab)

  14. Past, Present, Future

    … about physical repatriation and providing a model that Congolese scholars and artists can use to preserve and reclaim their cultural heritage.

    vt Repository record for Past, Present, Future (opens in a new tab)

  15. Nouvelle technique de test de type délai plus robuste à la variation d'impédance du réseau de distribution d'alimentation

    … (PSN, Power Supply Noise) produit pendant le mode test, qui diffère de celui induit pendant le mode fonctionnel. Quelques techniques de test de type SBAST ont été développées pour réduire cette chute de tension. Mais un aspect particulier a été négligé dans la littérature, à savoir l’impact de …

    ets-quebec Download PDF for Nouvelle technique de test de type délai plus robuste à la variation d'impédance du réseau de distribution d'alimentation (opens in a new tab)