Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 42 for “"3D digital image correlation"”

  1. Validation of 3D Digital Image Correlation Incremental Hole Drilling Residual Stress Measurement

    … the part, and are single use. The application of 3D DIC (three-dimensional digital image correlation) to the blind hole drilling method provides a larger measurement area and simplifies sample preparation. In this study, 3D DIC is applied to the blind hole drilling method of measuring residual …

    ut-knoxville Repository record for Validation of 3D Digital Image Correlation Incremental Hole Drilling Residual Stress Measurement (opens in a new tab)

  2. Deformation Analysis of Sand Specimens using 3D Digital Image Correlation for the Calibration of an Elasto-Plastic Model

    The use of Digital Image Correlation (DIC) technique has become increasingly popular for displacement measurements and for characterizing localized material deformation. In this study, a three-dimensional digital image correlation analysis (3D-DIC) was performed to investigate the displacements on …

    tamu Repository record for Deformation Analysis of Sand Specimens using 3D Digital Image Correlation for the Calibration of an Elasto-Plastic Model (opens in a new tab)

  3. Inverse Hybrid Method for Determining Explosive Loading on Plates Due to Buried Mines

    … plate was recorded using synchronized high-speed digital cameras, and then analyzed using 3D Digital Image Correlation software. Time-varying pressure profiles were input into an axisymmetric FEM simulation by fitting curves to data obtained from tests using Kolsky bars to measure pressures. These …

    maryland Repository record for Inverse Hybrid Method for Determining Explosive Loading on Plates Due to Buried Mines (opens in a new tab)

  4. Biomechanical Evaluation of Glenoid Baseplate Stability in Total Shoulder Arthroplasty

    … accurate displacement data continuously using a 3D digital image correlation system.In addition to the work concerning RSA, a new testing and analysis technique was developed for anatomic total shoulder arthroplasty (TSA). The primary focus of this work looked to quantify displacements of metal …

    buffalo Repository record for Biomechanical Evaluation of Glenoid Baseplate Stability in Total Shoulder Arthroplasty (opens in a new tab)

  5. Contact Mechanics of Fish Scale Inspired Exoskeletal Components on a Nonlinear Elastic Substrate

    … finite element (FE) computation and experimental 3D Digital Image Correlation (DIC). While previous works have focused on biological fish scales, fully embedded scale composites and perforation studies, this study investigates and develops a numerical model to quantify the contact behavior of …

    ucf Repository record for Contact Mechanics of Fish Scale Inspired Exoskeletal Components on a Nonlinear Elastic Substrate (opens in a new tab)

  6. Investigation of Failure Behaviour of a Glass-Fibre Reinforced Thermoplastic Composite

    … experimentally through the three-dimensional (3D) Digital Image Correlation (DIC) system. A novel failure metric based on the strains experienced by the fibre bundles is developed. From the experimental results, this failure metric is found to be able to eliminate path dependency effect and is …

    anu Repository record for Investigation of Failure Behaviour of a Glass-Fibre Reinforced Thermoplastic Composite (opens in a new tab)

  7. Multiscale experimentation & modeling of fatigue crack development in aluminium alloy 2024.

    … understand the macro and mesoscale as well. 3D Digital Image Correlation (DIC) was employed and the strain distributions (at the sample scale) were obtained for various loading conditions. High magnification camera based 2D DIC was then used and the strain measurements were also extracted at …

    whiterose Repository record for Multiscale experimentation & modeling of fatigue crack development in aluminium alloy 2024. (opens in a new tab)

  8. Development of a First-Generation Prototype Laboratory System for Rail Neutral Temperature Measurements

    … method for this work utilizes stereo vision and 3D Digital Image Correlation (StereoDIC) technology. It is a method that can acquire full-field deformation measurements. The measurements data then can be processed to obtain an RNT estimate and longitudinal stress calculation. Compared to the …

    south-carolina Repository record for Development of a First-Generation Prototype Laboratory System for Rail Neutral Temperature Measurements (opens in a new tab)

  9. Assessing the In-plane Shear Failure of GFRP Laminates and Sandwich Structures

    … experimental approach coupled with both 2D and 3D Digital Image Correlation (DIC) techniques to characterize the failure modes of sandwich structures. Constituent materials such as plain foams, laminates, and sandwich panels featuring different foam core densities and face-sheet thicknesses were …

    ohiolink Repository record for Assessing the In-plane Shear Failure of GFRP Laminates and Sandwich Structures (opens in a new tab)

  10. Solving large optimisation problems for improved robustness in dry fabrics forming applications

    In this thesis, a series of digital methods aiming to enhance the robustness of <br/>composite manufacturing processes are developed. Specifically, the dry Non-Crimp <br/>Fabric (NCF) forming process (which is a crucial stage in Liquid Composite Moulding <br/>(LCM)) serves as a case study to …

    bristol Repository record for Solving large optimisation problems for improved robustness in dry fabrics forming applications (opens in a new tab)

  11. On Structural Health Monitoring of Aircraft Adhesively Bonded Repairs

    … nondestructive techniques for validation such as 3D digital image correlation, X-ray radiography and thermography. Finally a feature selection strategy was developed through the analysis of the instantaneous properties of guided waves for damage detection purposes.

    whiterose Repository record for On Structural Health Monitoring of Aircraft Adhesively Bonded Repairs (opens in a new tab)

  12. Experimental Characterization and Validated Multi-Fidelity Analysis

    … to achieve deformation. The framework utilizes 3D digital image correlation techniques as a means of capturing physical deformations in physical space to compare to data generated by traditional modeling methods, including finite element analysis simulations and system performance predictions …

    tamu Repository record for Experimental Characterization and Validated Multi-Fidelity Analysis (opens in a new tab)

  13. Multi-Scale Architected Material Structural Optimization for Lightweight Structures and Elasto-Static Cloaking: From Design to Additive Manufacturing

    … embedded structures by integrating digital light processing additive manufacturing techniques within the architected material setting to fabricate the optimized results. Finally, the manufactured parts undergo mechanical testing with 3D Digital Image Correlation to evaluate the …

    gatech Repository record for Multi-Scale Architected Material Structural Optimization for Lightweight Structures and Elasto-Static Cloaking: From Design to Additive Manufacturing (opens in a new tab)

  14. Full-Field Measurement of the Taylor-Quinney Coefficient in Tension Tests of Ti-6Al-4V, Aluminum 2024-T351, and Inconel 718 at Various Strain Rates

    … measured on one side of the specimen using 2D or 3D Digital Image Correlation (DIC) and simultaneous temperature measurements are recorded on the opposite side of the specimen via infrared thermography. A method to determine β by combining the full-field temperature and strain measurements …

    ohiolink Repository record for Full-Field Measurement of the Taylor-Quinney Coefficient in Tension Tests of Ti-6Al-4V, Aluminum 2024-T351, and Inconel 718 at Various Strain Rates (opens in a new tab)

  15. Mode-I fracture parameters of quasi-brittle materials: direct evaluation using DIC and relationship with Mode-II interfacial parameters

    … further the knowledge on the fracture process, 3D digital image correlation (DIC) was employed. A new method is proposed to determine experimentally the critical value of the crack opening, which is then used to determine the size of the fracture process zone (FPZ). In addition, the Mode-I …

    bologna Repository record for Mode-I fracture parameters of quasi-brittle materials: direct evaluation using DIC and relationship with Mode-II interfacial parameters (opens in a new tab)

  16. Analytical models for laterally flexible rocking bodies

    … and pulse excitations were recorded using a 3D digital image correlation (DIC) system and accelerometers. Analysis of the data allows direct identification of the rigid body (including rocking and sliding motions) and flexible (lateral elastic deformation) components of the motion. Negligible …

    oxford Repository record for Analytical models for laterally flexible rocking bodies (opens in a new tab) Restricted access

  17. On the hydraulic bulge testing of thin sheets

    … Deformations of the bulge are monitored with a 3D digital image correlation (DIC) system. Bulging experiments on 0.040 in thick Al-2024-T3 sheets were successfully performed. The 3D nature of the DIC enables simultaneous estimates of local strains as well as the local radius of curvature. The …

    texas Repository record for On the hydraulic bulge testing of thin sheets (opens in a new tab)

  18. Electron beam welding process for joining thick gage section of martensitic stainless steels

    … with an automated non-contact three-dimensional (3D) digital image correlation (DIC) deformation measurement system, indicated that the tensile properties in both the as-welded and PWHTed conditions met the acceptance criteria in the ASME Section VIII & IX standard. A non-contact photometry system …

    ets-quebec

  19. Effect of Microdiscectomy on the Biomechanics of the Lumbar Facet Joints

    … by (1) the three-dimensional kinematics (3D) of the facets and (2) the strains in the capsular ligament surrounding the joint. These metrics were explored in two separate in vitro investigations using human cadaveric spinal specimens. In both studies, the specimens were tested with a spine …

    washington Repository record for Effect of Microdiscectomy on the Biomechanics of the Lumbar Facet Joints (opens in a new tab)

  20. 3D-printed hierarchical re-entrant honeycombs : design, mechanical properties, and deformation mechanisms

    … mechanisms of the H-ReHs, high-speed camera and 3D-digital image correlation have been utilized to analyze the internal strain field of the specimens under various loading conditions. It has been demonstrated that the 3D-printed H-ReHs exhibit enhanced specific stiffness, specific …

    msu Repository record for 3D-printed hierarchical re-entrant honeycombs : design, mechanical properties, and deformation mechanisms (opens in a new tab)

Page 1 of 3