Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 13 of 13 for “"3D dose distribution"”

  1. Multi-layer Strip Ionization Chamber for Proton Quality Assurance and Imaging

    … is needed to verify the quality of treatment dose delivery. Current clinical practice employs films or a two-dimensional (2D) detector to measure the dose at one or a few arbitrarily selected depths, which is insensitive to delivery error and time-consuming. A 3D dosimeter that can measure the …

    wustl Repository record for Multi-layer Strip Ionization Chamber for Proton Quality Assurance and Imaging (opens in a new tab)

  2. Biological Dose Accumulation in Image-guided Radiotherapy

    Dose accumulation (DA), the computation of the total delivered 3D dose distribution Da of a fractionated radiotherapy treatment using daily patient imaging, is getting established in clinical practice. Although the aim is to estimate the achieved biological outcome of the treatment, the principles …

    heid-diss Repository record for Biological Dose Accumulation in Image-guided Radiotherapy (opens in a new tab)

  3. Analysis of Radiation Therapy in Cancer Treatment using Machine Learning

    … and the relationship between the radiation dose distribution and breast size for whole-breast radiotherapy were investigated using statistical and machine learning methods. Two PRO measures; the M.D. Anderson symptom inventory for head and neck cancer, and the M.D. Anderson dysphagia …

    calgary Repository record for Analysis of Radiation Therapy in Cancer Treatment using Machine Learning (opens in a new tab)

  4. Combining Monte Carlo simulations and detector measurements for a novel quality assurance system of assembled brachytherapy eye plaques.

    … with an acrylic plaque holder to record the 2D dose distribution of the plaque perpendicular to the plaque central axis. The system is simulated in Monte Carlo to generate a 3D dose distribution. Calibrating the detector relative to the Monte Carlo results allows comparisons between simulated …

    ubc Repository record for Combining Monte Carlo simulations and detector measurements for a novel quality assurance system of assembled brachytherapy eye plaques. (opens in a new tab)

  5. Assessment on the Precision of Total Marrow Irradiation: From Clinical to Preclinical Implementation

    … regime before bone marrow transplant. Dose escalation of TBI produced decreased relapse rates in patients with leukemia; however, treatment-related deaths increased because of organ toxicity from TBI negating any potential therapeutic gain. In 2005 a new technique called Total Marrow …

    umn Repository record for Assessment on the Precision of Total Marrow Irradiation: From Clinical to Preclinical Implementation (opens in a new tab)

  6. Verification of the delivered patient radiation dose for non-coplanar beam therapy

    … North America. Its purpose is to deliver a high dose of radiation to the tumor while limiting doses to surrounding normal tissues. This is a challenging task when organs-at-risk (OARs) are in close proximity to the tumor. This is why recently many researchers have investigated the opportunity of …

    manitoba Repository record for Verification of the delivered patient radiation dose for non-coplanar beam therapy (opens in a new tab)

  7. Application of Machine Learning in Prostate Cancer External Beam Radiation Therapy to Improve Biochemical Failure-Free Survival Prediction

    … contains spatial information about the planned 3D dose distribution, could enhance the model performance. We did find improvement, and such improvement although relatively small was maintained when the model was validated with patients from other institutions. Additionally, we evaluated the …

    calgary Repository record for Application of Machine Learning in Prostate Cancer External Beam Radiation Therapy to Improve Biochemical Failure-Free Survival Prediction (opens in a new tab)

  8. Development and Validation of Advanced Techniques for Treatment Planning and Verification in Megavoltage Radiotherapy

    … great need for assuring quality of the radiation dose distributions generated by the advanced intensity modulated treatments (IMRT/VMAT). This is typically accomplished by the assessment of the treatment plan quality at the planning stage and then verification of the dose distributions through …

    usf Repository record for Development and Validation of Advanced Techniques for Treatment Planning and Verification in Megavoltage Radiotherapy (opens in a new tab)

  9. Beam monitoring and dosimetry for ultra-high dose rate radiobiology at laser-driven proton sources

    Ultra-high dose rate proton radiation has the potential to improve cancer treatment by reducing the normal tissue complication probability and, at the same time, reaching the tumor control probability known from conventional photon radiation therapy. Here, the ultra-high dose rate leads to normal …

    qucosa-diss Repository record for Beam monitoring and dosimetry for ultra-high dose rate radiobiology at laser-driven proton sources (opens in a new tab)

  10. Automated Intensity Modulated Radiation Therapy (IMRT) using fast dose and fluence calculations and Reinforcement Learning

    … Therapy (IMRT) gives the ability to shape a dose distribution through modulating the intensity of the radiation field at different points. This creates a 2D intensity pattern that is linked to a 3D dose distribution through the transport of radiation through the patient. Determining this …

    duke Repository record for Automated Intensity Modulated Radiation Therapy (IMRT) using fast dose and fluence calculations and Reinforcement Learning (opens in a new tab)

  11. Reconstruction de la dose absorbée in vivo en 3D pour les traitements RCMI et arcthérapie à l'aide des images EPID de transit

    … L'objectif de ce travail est de vérifier que la distribution de dose 3D absorbée dans le patient est conforme au calcul réalisé sur le système de planification de traitement (TPS) à partir de l'imageur portal (en anglais : Electronic Portal Imaging Device, EPID). L'acquisition est réalisée en …

    star-france Repository record for Reconstruction de la dose absorbée in vivo en 3D pour les traitements RCMI et arcthérapie à l'aide des images EPID de transit (opens in a new tab)

  12. Knowledge Discovery in Databases of Radiation Therapy Treatment Planning

    … anatomy atlas was established to generate 3D dose distribution guidance for the new patient. The anatomy pattern of the prostate cancer patient was parameterized with two descriptors. Each training case was represented in 2D feature space. All training cases were clustered using the …

    duke Repository record for Knowledge Discovery in Databases of Radiation Therapy Treatment Planning (opens in a new tab)

  13. Development of an AI-assisted computational method for the determination of individual patient radiation dose from computed tomography examinations

    … imaging modalities. The high patient radiation doses and frequency of examinations encountered in CT, have sparked an increased scientific and clinical interest in individual patient dose estimation. In 2014, the Council of the European Union issued Directive 2013/59/EURATOM, asking Member …

    greece Repository record for Development of an AI-assisted computational method for the determination of individual patient radiation dose from computed tomography examinations (opens in a new tab)