Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 8 of 8 for “"3D fluorescence microscopy"”
-
3D fluorescence microscopy with isotropic resolution on the nanoscale
… PSF, the better is the resolution. In standard fluorescence microscopy, however, diffraction dictates a PSF with a cigar-shaped main maximum, called the focal spot which extends over at least half the wavelength of light (L = 400-800 nm) in the focal plane and > L along the optic axis (z). While …
-
Single-Frame 3D Fluorescence Microscopy with Ultra-Miniature Lensless FlatScope
Modern biology increasingly relies on fluorescence microscopy, which is driving demand for smaller, lighter, and cheaper microscopes. However, traditional microscope architectures suffer from a fundamental tradeoff: as lenses become smaller, they must either collect less light or image a smaller …
-
2D timelapse and 3D fluorescence microscopy with applications to vascular tissue engineering
… cells (EC). Two dimensional timelapse fluorescence microscopy revealed rapid alkalinization occurring in cultured human aortic SMC exposed to well defined fluid flow profiles. The response was reversible and persisted for at least 20 min after flow initiation. The magnitude of the …
-
Three-Dimensional Fluorescence Microscopy by Optical Scanning Holography
As three-dimensional (3D) imaging and fluorescence techniques become standard in optical microscopy, novel approaches to 3D fluorescence microscopy are emerging. One such approach is based on the incoherent holography technique called optical scanning holography (OSH). The main advantage of …
-
A Pipeline for Automated Assessment of Cell Location in 3D Mouse Brain Image Sets
… brain tissue. Recent developments in automated 3D fluorescence microscopy, such as serial two- photon tomography (STP) and light sheet fluorescence microscopy, now allow for automated rapid 3D imaging of a complete mouse brain at cellular resolution. In combination with transsynaptic viral …
-
3D motion estimation and assessment in fluorescence microscopy volume sequences
… et l'évaluation de champs de vitesse 3D dans des séquences d'images 3D de microscopie à fluorescence. Nous nous sommes intéressés aux méthodes de mise en correspondance et aux méthodes variationnelles pour l'estimation du mouvement entre volumes 3D de la séquence. Pour l'appariement, …
-
Etude des composés phénoliques impliqués dans la réponse des feuilles de vigne au mildiou
… de stress biotiques et abiotiques. L’autofluorescence de ces composés phénoliques, dont la biosynthèse est induite dans les feuilles de vigne par P. viticola, en fait un potentiel marqueur naturel de l’infection. En effet, la faible autofluorescence bleu-verte des feuilles de vigne saines …