Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"3MHz"”.

  1. Measuring Brachial Artery Blood Flow Following a 3MHZ, 1.0 W/CM² Thermal Therapeutic Ultrasound Treatment

    … in blood flow to the brachial artery following a 3MHz thermal ultrasound at 1.0 W/cm2 treatment over the brachial artery. Blood flow was measured in time-averaged mean velocity using a diagnostic ultrasound machine prior to, and following an ultrasound treatment given at these parameters. Results …

    ndsu Repository record for Measuring Brachial Artery Blood Flow Following a 3MHZ, 1.0 W/CM² Thermal Therapeutic Ultrasound Treatment (opens in a new tab)

  2. A dual differential interferometer for measurements of broadband surface acoustic waves

    … bandwidth of more than two decades (eg. 30kHz to 3MHz for acoustic emission measurements) and may detect peak displacements in the sub-Angstrom range, it is designed to be insensitive to low-frequency specimen translation. Potential applications in nondestructive evaluation are discussed.

    vt Repository record for A dual differential interferometer for measurements of broadband surface acoustic waves (opens in a new tab)

  3. Tissue Temperature Increase Using Immersion Therapeutic Ultrasound at 3 MHz, 10 Minutes, 1.5 cm Depth, with Varying Intensities of 1.0 W/cm2, and 1.5 W/cm2

    … thermal effects of both 1.0W/cm2 and 1.5W/cm2 at 3MHz with continuous US while the triceps-surae is immersed in 37°C water. Intramuscular tissue temperature increases observed through the thermocouples at 1.5W/cm2 was compared to 1.0W/cm2. The study is needed to determine which intensity was most …

    ndsu Repository record for Tissue Temperature Increase Using Immersion Therapeutic Ultrasound at 3 MHz, 10 Minutes, 1.5 cm Depth, with Varying Intensities of 1.0 W/cm2, and 1.5 W/cm2 (opens in a new tab)

  4. A Dual-Supply Buck Converter with Improved Light-Load Efficiency

    … to work with a constant switching frequency of 3MHz. Without sacrificing output frequency spectrum or output ripple, an efficiency improvement of up to 20 percent is obtained at light load.

    tamu Repository record for A Dual-Supply Buck Converter with Improved Light-Load Efficiency (opens in a new tab)

  5. Nonparametric and Parametric Methods for Solar Oscillation Spectra

    … Advanced Composition Explorer (ACE) on the 2 − 3mHz band and (b) quantification of the presence of modal structure in secondary cosmic rays (specifically neutrons) on Earth.

    queens Repository record for Nonparametric and Parametric Methods for Solar Oscillation Spectra (opens in a new tab)

  6. The radio spectrum requirements of broadband power line telecommunications systems.

    … theory to predict the data capacity of arbitrary 3MHz sub bands. The results of the measurement programme are used to determine an optimum frequency band plan for PLT systems, taking account of the needs of the systems and the protection of other users of the HF spectrum. An example of how the …

    the-open-u Download PDF for The radio spectrum requirements of broadband power line telecommunications systems. (opens in a new tab)

  7. Temperature Changes Associated with Ultrasound-Based Changes in Masseter Myalgia

    … changes between groups treated with1MHz and 3MHz therapeutic ultrasound. 3) if there is a difference in mean temperatures from pre and post-treatment. 4) if there is a segmental effect on the temperature of the temporalis muscle from pre to post-treatment. Methods. Twenty-two adult females …

    buffalo Repository record for Temperature Changes Associated with Ultrasound-Based Changes in Masseter Myalgia (opens in a new tab)

  8. Acoustoelectric Imaging of Deep Brain Stimulation Currents

    … from the skull, US frequencies are limited to <3MHz or >0.5mm spatial resolution. In this study, I use AEI to detect current pulses as short as 100μs and weak at 1.5 mA from two different DBS electrodes and through four different skulls. At 2.5 MHz, transcranial AEI accurately detects DBS …

    arizona-thes Repository record for Acoustoelectric Imaging of Deep Brain Stimulation Currents (opens in a new tab)

  9. Multiplexed Photometry And Fluorimetry Using Multiple Frequency Channels

    … frequency multiplexing design operated at 3MHz; however, it required electro optical modulators [50], which are too expensive and bulky for portable applications. In contrast to both approaches, the objective of this research is to use frequency division multiplexing to perform …

    wayne-thes Repository record for Multiplexed Photometry And Fluorimetry Using Multiple Frequency Channels (opens in a new tab)

  10. Modeling of weak scatterers in a transducer beam

    … The results agreed closely (RMSE < 1 dB, 1.5 to 3MHz) for three different spheroid size configurations ranging from nearly spherical (B/A = 1.18, where B and A are major and minor axis radii) to strongly non-spherical (B/A = 5.2). The modeling approach was found to consistently represent …

    uiuc Repository record for Modeling of weak scatterers in a transducer beam (opens in a new tab)

  11. Digital enhancement techniques for fractional-N frequency synthesizers

    … better than -106dBc/Hz in-band noise and 3MHz PLL bandwidth at 4.5GHz output frequency using 50MHz reference. The PLL achieves excellent jitter performance of 490fsrms, while consumes only 3.7mW. This translates to the best reported jitter-power figure-of-merit (FoM) of -240.5dB among …

    uiuc Repository record for Digital enhancement techniques for fractional-N frequency synthesizers (opens in a new tab)