Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"3d dosimetry"”.

  1. Clinical and Research Applications of 3D Dosimetry

    … higher accuracy in delivery. Comprehensive 3D dosimetry with PRESAGE® 3D dosimeters read out via optical CT has the potential to detect errors that would be missed by current systems of measurement, and thereby improve the rigor of current QA techniques through providing high-resolution, …

    duke Repository record for Clinical and Research Applications of 3D Dosimetry (opens in a new tab)

  2. Evaluation of Presage® Dosimeters For Brachytherapy Sources and The 3D Dosimetry and Characterization of The New Agx100 125I Seed Model

    … source designs and techniques, method of 3D dosimetry for treatment dose verifications would better ensure accurate patient radiotherapy treatment. This study was aimed to first evaluate the 3D dose distributions of the low-dose rate (LDR) Amersham 6711 OncoseedTM using PRESAGE® dosimeters …

    uthsc Repository record for Evaluation of Presage® Dosimeters For Brachytherapy Sources and The 3D Dosimetry and Characterization of The New Agx100 125I Seed Model (opens in a new tab)

  3. Measurement of The Electron Return Effect Using Presage Dosimeter

    … of dose enhancement over a three-dimensional (3D) volume around tissue interfaces inside the patient body, giving rise to the need for 3D dosimetry. If proven reliable in the magnetic field, 3D dosimetry will provide a more rigorous means for the quality assurance (QA) of MRgRT than …

    uthsc Repository record for Measurement of The Electron Return Effect Using Presage Dosimeter (opens in a new tab)

  4. Εφαρμογή τρισδιάστατης χημικής δοσιμετρίας στην ακτινοθεραπεία δερματικών νόσων

    … EBT3 films as well as the one of a novel 3D radiochromic micelle gel dosimeter, LCV-Pluronic, coupled with 3D optical computed tomography (OCT) imaging system. EBT3 films were calibrated in air for all beam qualities of a clinical unit (40-220 kVp). These data along with Monte Carlo (MC) …

    greece Repository record for Εφαρμογή τρισδιάστατης χημικής δοσιμετρίας στην ακτινοθεραπεία δερματικών νόσων (opens in a new tab)

  5. An optical computed tomography scanner for three dimensional gel dosimetry of radiotherapy dose distributions

    … calculate patient specific three dimensional (3D) radiation dose distributions. Treatment planning system (TPS) calculated doses are evaluated by clinicians to ensure suitable dose coverage of targeted tumours and the avoidance of excessive doses to normal tissues. The accuracy of the TPS must …

    adelaide Repository record for An optical computed tomography scanner for three dimensional gel dosimetry of radiotherapy dose distributions (opens in a new tab)

  6. Polymer Gel Dosimetry in Magnetic Resonance-Image Guided Radiation Therapy

    … for MR-IGRT treatment plan verification with 3D dosimeters arose due to the presence of the strong magnetic field altering dose depositions in 3D. Furthermore, vendors only provide MR-compatible electronics that measure dose distributions at best in quasi-3D. The implementation of 3D dosimetry …

    houston Repository record for Polymer Gel Dosimetry in Magnetic Resonance-Image Guided Radiation Therapy (opens in a new tab)

  7. X-ray computed tomography for performing polymer gel dosimetry : a feasibility study

    … sensitive, high resolution three dimensional (3D) dosimeter. Polymer gels are novel, inherently 3D, tissue equivalent radiation dosimeters. Traditionally, dose distributions recorded in polymer gel are read out using magnetic resonance imaging (MRI). Presented here is a feasibility study on a …

    ubc Repository record for X-ray computed tomography for performing polymer gel dosimetry : a feasibility study (opens in a new tab) Download PDF for X-ray computed tomography for performing polymer gel dosimetry : a feasibility study (opens in a new tab)

  8. Validation of conformal radiotherapy treatments in 3D using polymer gel dosimeters and optical computed tomography

    Polymer gel dosimeters are a three dimensional (3D) dosimetry system that may be conveniently applied for verifying highly conformal radiation therapies where standard dosimetry techniques are insufficient. Polymer gel dosimetry with optical computed tomography (OptCT) can be used to measure …

    queens Repository record for Validation of conformal radiotherapy treatments in 3D using polymer gel dosimeters and optical computed tomography (opens in a new tab)

  9. Development of a Voxel-Based Monte Carlo Radiation Dosimetry Methodology for a Targeted Alpha Particle Therapy

    … However, clinical methods for determining 3D radiation dosimetry in patients with multiple metastatic lesions are needed to support clinical translation of novel targeted alpha particle therapies for personalized treatment, especially in patients that have previously received radiotherapy. …

    usf Repository record for Development of a Voxel-Based Monte Carlo Radiation Dosimetry Methodology for a Targeted Alpha Particle Therapy (opens in a new tab)

  10. Characterization of The New Xoft Axxent Electronic Brachytherapy Source Using Presage(Tm)

    … electronic brachytherapy, an accurate method of 3D dosimetry is needed to ensure understanding of dose distributions, which can improve patient care. The aim of this study was to characterize the Xoft Axxent electronic brachytherapy source using PRESAGETM dosimeters in order to obtain independent …

    uthsc Repository record for Characterization of The New Xoft Axxent Electronic Brachytherapy Source Using Presage(Tm) (opens in a new tab)

  11. Quantitative 3D Optical Imaging: Applications in Dosimetry and Biophysics

    … have used optical-CT for the readout of 3D dosimeters, but it is yet to be a clinically relevant tool as the technology is too slow to be considered practical. Biologists have used the technique for structural imaging, but have struggled with emission tomography as the reality of photon …

    duke Repository record for Quantitative 3D Optical Imaging: Applications in Dosimetry and Biophysics (opens in a new tab)

  12. Deep Learning-based Onboard Image Guidance and Dose Verification for Radiation Therapy

    … imaging are two promising methods to reconstruct 3D dose deposition noninvasively in real-time during the treatment, but their images are severely distorted by the single-view measurements. Essentially, reconstructing images from under-sampled acquisition is an ill-conditioned inverse problem. Our …

    duke Repository record for Deep Learning-based Onboard Image Guidance and Dose Verification for Radiation Therapy (opens in a new tab)

  13. Evaluation of Presage® As A 3D Dose Verification to ol In Proton Beams

    … shortcoming has led to an interest in a robust 3D dosimeter with dosimetric accuracy matching that of traditional devices. PRESAGE®, a novel radiochromic dosimeter, has shown promise in dose verification of complex IMRT treatments. As such, there have been numerous studies of PRESAGE® as a 3D …

    uthsc Repository record for Evaluation of Presage® As A 3D Dose Verification to ol In Proton Beams (opens in a new tab)

  14. 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry

    Polymer gel dosimetry has been used since the 1990s, and several studies have shown that this detector system can be used for verification of static absorbed dose distributions in three dimensions (3D). Its unique properties, such as high resolution, normal tissue equivalence and independency of …

    lund Repository record for 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry (opens in a new tab) Download PDF for 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry (opens in a new tab)

  15. Volumetric, Magnetic Resonance-Visible, and Radiation-Sensitive Detectors For Magnetic Resonance Image-Guided Radiation Therapy

    … assurance tools can provide at best quasi-3D sampling of the dose distribution and cannot be MR imaged. As a result, there was a growing need for volumetric, MR-visible, and radiation-sensitive detectors for MR-IGRT applications. To fill this need for volumetric dose quality assurance, this …

    uthsc Repository record for Volumetric, Magnetic Resonance-Visible, and Radiation-Sensitive Detectors For Magnetic Resonance Image-Guided Radiation Therapy (opens in a new tab)

  16. Evaluation of yttrium-90 positron emission tomography dosimetry

    … tumors. Radioembolization dose planning and dosimetry are based on crude, inaccurate assumptions due to the lack of knowledge of patient specific 90Y microsphere distribution. In recent years, the very small 3.1867e-5 internal pair production decay branch of 90Y has been shown to allow for …

    purdue-thes Repository record for Evaluation of yttrium-90 positron emission tomography dosimetry (opens in a new tab)

  17. Readout of polymer gel dosimeters using a prototype fan-beam optical computed tomography scanner

    New radiation therapy (RT) techniques for treating cancer are continually under development. Our ability to demonstrate the safe and accurate implementation of new RT treatment techniques is dependent on the information provided by current dosimetric tools. Advanced dosimetric tools will become …

    uvic Repository record for Readout of polymer gel dosimeters using a prototype fan-beam optical computed tomography scanner (opens in a new tab)

  18. Quality Assurance of Advanced Treatment Modalities Using Presage® Dosimeters

    … such as PRESAGE® is able to provide a complete 3D measured dosimetry dataset with one treatment plan delivery. It was hypothesized that a PRESAGE® dosimeter would agree with 2D measurements within ±5%/3mm using a gamma index analysis. The PRESAGE® dosimeter will detect dose discrepancies not …

    uthsc Repository record for Quality Assurance of Advanced Treatment Modalities Using Presage® Dosimeters (opens in a new tab)

Page 1 of 2