Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 13 of 13 for “"4D Computed"”
-
ASSESSMENT OF REGIONAL CARDIAC FUNCTION FROM 4D COMPUTED TOMOGRAPHY
The current method for diagnosing Coronary Heart Disease (CHD) often begins with a nuclear medicine stress SPECT exam. This exam is expensive in multiple ways: 1) it is time consuming and costly, 2) it exposes the patient to relatively high levels of radiation, 3) it has limited sensitivity and …
-
Application of Electrical Resistivity Geophysical Monitoring for Detection of Preferential Flow
… using advanced observation techniques like 4D computed tomography. Electrical resistivity was used to monitor the progression of uniform wetting fronts as well as preferential flow and infiltration through macropore networks. Results indicate that certain characteristics in the response of …
-
Multimodality and Nonrigid Image Registration with Application to Diffusion Tensor Imaging
… data volume and also on clinically acquired 4D computed tomography image data sets. In the same vein, we extend our nonrigid registration approach to align diffusion tensor images for multiple components by enabling explicit optimization of tensor reorientation. Incorporating tensor …
-
Evaluation of Deformable Image Registration For Improved 4D Ct-Derived Ventilation For Image Guided Radiotherapy
… functional loss following thoracic radiotherapy. 4D computed tomography (CT), developed for radiotherapy treatment planning, is a relatively new imaging technique that allows the acquisition of a time-varying sequence of 3D CT images of the patient's lungs through the respiratory cycle. Guerrero …
-
Investigation into the use of Four Dimensional Cone Beam Computed Tomography for Internal Target Volume definition in Lung Stereotactic Ablative Body Radiation
… ablative body radiation (SABR) treatment using 4D Computed Tomography (4DCT) and 4D Cone Beam Computed Tomography (4DCBCT) technologies. 4DCT is considered the gold standard for ITV definition (Wang et al., 2020). The accuracy of ITV definitions was assessed by comparing target overlap, volume …
-
Improvements In Four-Dimensional and Dual Energy Computed to mography
Dual energy and 4D computed tomography (CT) seek to address some of the limitations in traditional CT imaging. Dual energy CT, among other purposes, allows for the quantification and improved visualization of contrast materials, and 4D CT is often used in radiation therapy applications as it allows …
-
Development and Optimization of Four-dimensional Magnetic Resonance Imaging (4D-MRI) for Radiation Therapy
… In clinical practice, four-dimensional (4D) imaging has been popular in For RT motion management. It provides temporal information about tumor and organ at risk motion, and it permits patient-specific treatment planning. The most common contemporary imaging technique for identifying tumor …
-
Improvements In Robustness and Optimality of Intensity-Modulated Proton Therapy Plans For Lung Cancer Patients With 4-Dimensional Robust Optimization
… a novel four-dimensional robust optimization (4DRO) method and find an appropriate optimization strategy to make IMPT dose distributions less sensitive to both respiratory motion as well as to setup and range uncertainties simultaneously. For full 4DRO, the effect of respiratory motion, …
-
Radiation Therapy Optimization under Uncertainty for Lung Cancer: Interplay Effects and Tumor Shrinkage
… processes on the moving patient described by 4D computed tomography (4DCT) during the dose delivery process by linking timestamps of each on/off switch of proton spots, spills, energies, and fields to patient respiratory cycles. We introduce a clinically applicable metric for clinicians to use …
-
Comparative Motion and Dosimetric Analysis of Organs at Risk near Pancreatic Tumors Treated with Stereotactic Body Radiation Therapy with and without Abdominal Compression using 4DCT Datasets
… 1 with IMRT. All patients had two plans and two 4D computed tomography (4DCT) datasets, one with AC and one without AC. Plans were normalized so that 95% of the PTV received 100% prescription dose; the same total MUs and MU/beam were used in both (with and without) AC plans for each patient. Four …
-
Breathing motion detection in computed tomography using data consistency conditions
… tomodensitométrie (TDM) quadridimensionnelles (4D) sont utilisées pour la planification de la radiothérapie des tumeurs thoraciques et abdominales supérieures afin de tenir compte des mouvements respiratoires. Cette modalité repose sur l’hypothèse que le cycle respiratoire est périodique, ce qui …
-
Imagerie fonctionnelle des tumeurs de la tête et du cou
RESUME : Introduction : L'imagerie médicale s'est enrichie de la possibilité de fournir des données fonctionnelles nouvelles, potentiellement utiles à visée diagnostique ou pronostique, pour guider au mieux les choix thérapeutiques. Le but de ce travail est de développer des biomarqueurs dans la …
-
Optimization of Image Guided Radiation Therapy for Lung Cancer Using Limited-angle Projections
… as the 3D-DTS technique, but uses the planning 4D computed tomography (CT) to synthesize a phase-matched reference DTS to register with the on-board DTS for tumor localization. Of the 324 different scenarios simulated using the extended cardiac torso (XCAT) digital phantom, the phase-matched DTS …