Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 37 for “"4D Flow MRI"”.

  1. Phase unwrapping of 4D-flow MRI data with graph cuts.

    A common issue when measuring velocity utilizing 4D flow magnetic resonance imaging (MRI) is aliasing that occurs because of a low velocity encoding parameter (VENC). Aliasing can be avoided if the velocity encoding parameter is set above the largest velocity quantity. However, when this is done …

    louisville Repository record for Phase unwrapping of 4D-flow MRI data with graph cuts. (opens in a new tab)

  2. Developing Indices of Pulse Wave Encephalopathy Risk Using 4D Flow MRI

    Dementia is hypothesised to develop over several decades, prompting the opportunity to develop indices that can identify the related early dysfunction or risk. Current literature supports that unregulated or pathological cerebral hemodynamics initiate brain damage via a process termed pulse wave …

    auckland-ms Repository record for Developing Indices of Pulse Wave Encephalopathy Risk Using 4D Flow MRI (opens in a new tab)

  3. Registration of 3D Cine MRI to 4D Flow MRI via Localization

    Cardiac 4D Flow magnetic resonance imaging (4D Flow MRI) is a recent powerful technology that uniquely enables in-vivo acquisition of time-varying volumetric blood flow velocity field information in the three spatial dimensions over the cardiac cycle. Hence, 4D Flow MRI has emerged as an important …

    calgary Repository record for Registration of 3D Cine MRI to 4D Flow MRI via Localization (opens in a new tab)

  4. Investigating Mitral Regurgitation using 4D-flow MRI-based Markers and Personalized Experimental Models

    … MR is defined as systolic retrograde blood flow from the left ventricle (LV) into the left atrium (LA) and has the most frequent indications for valve surgery. Thus, early detection and assessment are important. Echocardiography (Doppler) is the first-line assessment of MR; however, it is …

    calgary Repository record for Investigating Mitral Regurgitation using 4D-flow MRI-based Markers and Personalized Experimental Models (opens in a new tab)

  5. Unraveling Flow-Dynamic Characterization of the Ascending Aorta and Left Ventricle in Bicuspid Aortic Valve Pathologies via 4D Flow MRI

    … Advanced magnetic resonance imaging (MRI), particularly time-resolved three-dimensional phase-contrast velocity encoding (4D flow MRI), enables comprehensive quantification of blood flow and ventricular energetics, offering the potential for novel biomarkers to improve risk …

    calgary Repository record for Unraveling Flow-Dynamic Characterization of the Ascending Aorta and Left Ventricle in Bicuspid Aortic Valve Pathologies via 4D Flow MRI (opens in a new tab)

  6. Efficient cardio-vascular 4D-Flow MRI enabled CFD to improve in-silico predictions of post-surgical haemodynamics in individual patients

    This thesis focuses on creating a workflow that combines four dimensional flow magnetic resonance imaging with computational fluid dynamics techniques, and identifying the main difficulties that are associated with patient-specific modelling. With further development, the proposed work- flow will …

    whiterose Download PDF for Efficient cardio-vascular 4D-Flow MRI enabled CFD to improve in-silico predictions of post-surgical haemodynamics in individual patients (opens in a new tab)

  7. Patient-specific multi-dimensional CFD simulations based on 4D Flow-MRI for the haemodynamic assessment of aortic dissections and perfusion optimisation of vascular grafts

    … failure mechanisms are related to the internal flow regime and post-surgical haemodynamics.At present, it is difficult to predict the internal haemodynamics within these grafts before they are deployed. Therefore, this thesis seeks to understand whether we can use 4D Flow MRI in combination with …

    strathclyde Repository record for Patient-specific multi-dimensional CFD simulations based on 4D Flow-MRI for the haemodynamic assessment of aortic dissections and perfusion optimisation of vascular grafts (opens in a new tab)

  8. Motion and Blood Flow Analysis of Cardiovascular Magnetic Resonance Imaging using Deep Learning

    … techniques are CMR tagging and four-dimensional flow magnetic resonance imaging (4D Flow MRI). CMR tagging is a signal magnitude-based technique that enables measurement of cardiac function from regional deformation, while 4D Flow MRI is a phase-contrast imaging technique capable of measuring …

    auckland-ms Repository record for Motion and Blood Flow Analysis of Cardiovascular Magnetic Resonance Imaging using Deep Learning (opens in a new tab)

  9. Integrating Flow Imaging and Deep Learning into Patient-Specific Models Following Myocardial Infarction

    4D-flow magnetic resonance imaging (MRI) provides non-intrusive blood flow reconstructions in the left ventricle (LV) and other cardiac chambers and has the potential to become a key tool in both research and clinic. However, low spatio-temporal resolution and the presence of significant noise …

    whiterose Download PDF for Integrating Flow Imaging and Deep Learning into Patient-Specific Models Following Myocardial Infarction (opens in a new tab)

  10. 4D Flow in Tetralogy of Fallot: Novel diagnostic cardiovascular examination methods

    Background: Abnormal intracardiac blood flow patterns may exacerbate ventricular remodeling leading to adverse cardiac outcomes. Four-dimensional flow cardiac magnetic resonance imaging (4D flow) enables study of a spectrum of flow features, including vorticity and its impact on cardiac …

    auckland-ms Repository record for 4D Flow in Tetralogy of Fallot: Novel diagnostic cardiovascular examination methods (opens in a new tab)

  11. Overcoming missing ground truth and multi-vendor dependent problems in cardiac valves quantitative evaluation through cardiac magnetic resonance imaging (CMR)

    … advantages. Cardiac magnetic resonance imaging (MRI) is a key modality for VHD assessment, offering comprehensive anatomical and functional insights. Image acquisition and post-processing need optimization to enhance valvular assessment. Its clinical application is still hindered by the lack of …

    fu-berlin Repository record for Overcoming missing ground truth and multi-vendor dependent problems in cardiac valves quantitative evaluation through cardiac magnetic resonance imaging (CMR) (opens in a new tab)

  12. Four-Dimensional Blood Flow Analysis in Patients with Repaired Tetralogy of Fallot: Development of Novel Tools to Analyze Turbulence

    … used today include Magnetic Resonance Imaging (MRI), X-Ray, Computed Tomography, and Ultrasound, just to name a few. Due to the unique ability of these imaging modalities to obtain information, much research and technological improvements have been discovered to obtain as much information as we …

    calgary Repository record for Four-Dimensional Blood Flow Analysis in Patients with Repaired Tetralogy of Fallot: Development of Novel Tools to Analyze Turbulence (opens in a new tab)

  13. Denoising and super-resolution of in-vitro 4E flow MRI in a stenotic phantom model using physics-informed neural networks.

    In recent years, the use of 4D flow MRI has revolutionized cardiovascular imag- ing by providing comprehensive data on blood flow dynamics over time. However, the limited spatial and temporal resolution of this imaging modality can hinder the accurate assessment of complex hemodynamic phenomena. …

    louisville Repository record for Denoising and super-resolution of in-vitro 4E flow MRI in a stenotic phantom model using physics-informed neural networks. (opens in a new tab)

  14. Comparative Analysis of Pressure Mapping Methods in Repaired Tetralogy of Fallot: Four-Dimensional Blood Flow Hemodynamics Assessment and Development of a Novel Pressure Mapping Tool

    … heart defect (CHD) that alters normal blood flow through the heart and accounts for 10% of all CHD. Pulmonary stenosis and regurgitation are common in adults who have undergone TOF repair (rTOF) and can impact the load on the right ventricle, blood flow pressure, and pulmonary hemodynamics. …

    calgary Repository record for Comparative Analysis of Pressure Mapping Methods in Repaired Tetralogy of Fallot: Four-Dimensional Blood Flow Hemodynamics Assessment and Development of a Novel Pressure Mapping Tool (opens in a new tab)

  15. In Vivo Investigation of Left Ventricular Flow Dynamics and Energetic Dissipation in Aortic Regurgitation Using 4D-flow Magnetic Resonance Imaging

    … estimate but fails to capture the complex flow and mechanical alterations underlying disease progression. Four-dimensional flow magnetic resonance imaging (4D-flow MRI) has emerged as a powerful tool to non-invasively assess cardiovascular hemodynamics more than standard volumetric …

    concordia Download PDF for In Vivo Investigation of Left Ventricular Flow Dynamics and Energetic Dissipation in Aortic Regurgitation Using 4D-flow Magnetic Resonance Imaging (opens in a new tab)

  16. 4D reduced TE (RTE) spiral phase contrast NRI for rapid quantification and visualization of blood flow and hemodynamics.

    4D flow Phase Contrast MRI is a relatively new technique in MRI which is capable of deriving time-resolved three-dimensional velocity fields in a 3D volume noninvasively. 4D flow imaging is a 3D k-space acquisition where for the third dimension, an additional phase-encoding step is required. The …

    louisville Repository record for 4D reduced TE (RTE) spiral phase contrast NRI for rapid quantification and visualization of blood flow and hemodynamics. (opens in a new tab)

  17. Mri Assessment Of Maternal Uteroplacental Circulation In Pregnancy

    … was that magnetic resonance imaging (MRI) could noninvasively evaluate uteroplacental function in vivo through a combination of arterial spin labeling (ASL), 4D flow, and time-of-flight (TOF) techniques which were already effective in the evalution of other cardiovascular diseases. …

    penn Repository record for Mri Assessment Of Maternal Uteroplacental Circulation In Pregnancy (opens in a new tab)

  18. Wave-CAIPI for Accelerated Dynamic MRI of the Thorax

    … dynamic applications: self-gated dynamic 3D lung MRI during free breathing and cardiac 4D flow MRI. Dynamic 3D Lung MRI By employing wave-CAIPI sampling in self-gated, free-breathing dynamic 3D lung MRI for the purpose of radiotherapy treatment planning, the image quality of accelerated scans …

    wurz-thes Repository record for Wave-CAIPI for Accelerated Dynamic MRI of the Thorax (opens in a new tab)

  19. Advanced cardiac imaging analysis in atrial fibrillation and its hemodynamics

    … precise therapeutic approach based on individual flow is required. 4D flow magnetic resonance imaging (MRI) offers comprehensive measurement of flow velocity throughout the entire cardiac cycle in three dimensions. While previous studies have explored the application of 4D flow techniques in AF, …

    calgary Repository record for Advanced cardiac imaging analysis in atrial fibrillation and its hemodynamics (opens in a new tab)

  20. 4D Flow Magnetic Resonance Imaging and Computational Fluid Dynamics for the Study of Complex Blood Flow Patterns in Carotid Webs

    … antiplatelet therapy. Understanding the complex flow alterations induced by CaW that lead to thrombus formation and subsequent stroke is crucial to improve clinical outcomes. To characterize flow patterns associated with CaW, advanced imaging techniques such as three-dimensional, …

    gatech Repository record for 4D Flow Magnetic Resonance Imaging and Computational Fluid Dynamics for the Study of Complex Blood Flow Patterns in Carotid Webs (opens in a new tab)

Page 1 of 2