Showing 1 to 20 of 35 for “"4D imaging"”.
-
4D imaging of paper : a novel method to characterize deformation mechanisms
… to acquire time-resolved 3D image volumes (4D Imaging) of different materials including paper that can be utilized for direct observation of their microstructure under deformation. Considering the importance of inter-fibre bonding in prediction of paper behaviour, especially when paper is …
-
Towards attosecond 4D imaging of atomic-scale dynamics by single-electron diffraction
… of atomic-scale structural dynamics (4D imaging) due to the short de Broglie wavelength of fast electrons. This requires electron pulses with durations on the order of femtoseconds or below. Challenges arise from Coulomb repulsion and dispersion of non-relativistic electron wave …
-
An innovative assessment of the dynamics of facial movements in surgically managed Unilateral Cleft Lip using 4D imaging
… has been carried out previously using 2D and 3D imaging modalities. 2D imaging systems do not analyse the depth of images and therefore these methods lose out on an important dimension of facial morphology that needs to be assessed. 3D systems analyse the depth of images but are unable to assess …
-
Assessment of the correlation between patients with a unilateral cleft lip and palate (UCLP) and non-cleft individuals regarding the duration and speed of maximum smile using 4d imaging
… Objective quantification of dynamic motion with 4D imaging could allow comparison of different treatments, monitor patients for worsening and guide future intervention. Each expression has specific muscle groups that undergo contraction and relaxation during different phases of movement. Some of …
-
Nano-scale 4D mapping by Scanning Transmission X-ray Microscopy
… to be added to the 3 dimension of volume imaging. Multi chemical 3D imaging is defined as 4D imaging. To reduce the radiation damage to PFSA, the compressed sensing (CS) algorithm has been used. The results show that the total radiation damage can be reduced below the critical dose, and …
-
Combined Segmentation and Hemodynamic Analysis of Cerebrovascular Structures using Arterial Spin Labeling
… spin labeling magnetic resonance angiography (4D ASL MRA) is a non-invasive imaging modality used to acquire dynamic images of cerebrovascular structures. It can achieve high spatial and temporal resolution, while capturing morphological and blood flow data. Recent scientific studies have used …
-
Elucidating the mechanisms regulating unilateral cytokinesis in Caenorhabditis elegans zygotes
… remain unclear due to difficulties in imaging both the cell surface and the division plane. In this thesis, we addressed this question using Caenorhabditis elegans embryos as a model system. We developed computational and experimental methods to analyze both the cell surface and ring …
-
The correlation between static and dynamic facial dysmorphology in unilateral cleft lip and palate (UCLP)
… at both rest and maximum smile and dynamic (4D) facial dysmorphology as represented by the frame of maximum asymmetry during a maximum smile in unilateral cleft lip and palate (UCLP). When maximum asymmetry occurs during a maximum smile was also analysed. Design and setting – This study was …
-
The assessment of distorted facial muscles movements in facial palsy
… evaluating the clinical impact of facial palsy. 4D imaging is a reliable modality for recording the dynamics of facial expressions. This study aimed to assess distorted facial muscles movements in unilateral facial palsy and mathematically validate clinical grading indices. Material & Method The …
-
Development of a High Resolution Microvascular Imaging Toolkit for Optical Coherence Tomography
… development of new optical coherence tomography imaging systems and techniques to improve in vivo 3D microvascular imaging. Specifically these systems and techniques were proposed to address three main problems with 3D Doppler optical coherence tomography imaging: (a) Motion artefacts, (b) angle …
-
Understanding the Organization, Location, and Interactions of Actin-based Structures During Drosophila Dorsal Closure
… and dynamic medioapical arrays. I used live, 4D imaging to observe Drosophila dorsal closure, a model of epithelial sheet morphogenesis. I compared four fluorescently tagged F-actin probes widely used by Drosophila researchers to determine which was optimal for imaging dorsal closure. I …
-
Staphylococcal Infection Dynamics
… was to develop methodology that enables the imaging of infected, living transgenic embryos, over extended time scales. Having established mounting and imaging parameters, infection progression was followed using fluorescent S. aureus reporter strains and fluorescently labelled host …
-
Four-Dimensional Imaging of Respiratory Motion in the Radiotherapy Treatment Room Using a Gantry Mounted Flat Panel Imaging Device
<p>Imaging respiratory induced tumor motion in the radiation therapy treatment room could eliminate the necessity for large motion encompassing margins that result in excessive irradiation of healthy tissues. Currently available image guidance technologies are ill-suited for this task. …
-
Novel Computational Approaches For Multidimensional Brain Image Analysis
… addressing challenging problems in 1D, 2D/3D and 4D neuroimaging by developing novel algorithms that combine signal processing and machine learning techniques. One of these challenging tasks is the accurate localization of the eloquent language cortex in brain resection pre-surgery patients. This …
-
Improvements In Four-Dimensional and Dual Energy Computed to mography
Dual energy and 4D computed tomography (CT) seek to address some of the limitations in traditional CT imaging. Dual energy CT, among other purposes, allows for the quantification and improved visualization of contrast materials, and 4D CT is often used in radiation therapy applications as it allows …
-
Development and Optimization of Four-dimensional Magnetic Resonance Imaging (4D-MRI) for Radiation Therapy
… In clinical practice, four-dimensional (4D) imaging has been popular in For RT motion management. It provides temporal information about tumor and organ at risk motion, and it permits patient-specific treatment planning. The most common contemporary imaging technique for identifying tumor …
-
Development of Optical Coherence Tomography Systems for Ophthalmic Imaging and Intrasurgical Guidance
… tomography (OCT) is a non-contact volumetric imaging modality that is well suited to image the anterior and posterior human eye in vivo. The success of OCT in clinical ophthalmology motivated the development of intraoperative OCT to overcome the limitations of the operating microscope for …
-
DEPTH CONVERSION, RESERVOIR VOLUMES, SEAL INTEGRITY, AND 4D MONITORING FOR CO2 SEQUESTRATION
… (GRV) estimation, fault seal analysis, and 4D seismic monitoring. The V0-k method of depth conversion is investigated with its mathematical foundations and how its parameters can be derived from commonly available depth-time data from wells. The research demonstrates that obtaining …
-
High-Frequency Phased Array Ultrasonic Transducer
… array structure can even realize real-time 3D imaging which is so called 4D imaging. More intuitive and detailed image information can be given under this scan mode. In this project, two types of devices of PMN-PT single crystal based phased array ultrasonic transducer with high frequency were …