Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"4D-CBCT"”.

  1. IMAGE-BASED RESPIRATORY MOTION EXTRACTION AND RESPIRATION-CORRELATED CONE BEAM CT (4D-CBCT) RECONSTRUCTION

    … Respiration-correlated or four-dimensional CT (4DCT) imaging techniques have been recently integrated into imaging systems for verifying tumor position during treatment and managing respiration-induced tissue motion. The quality of the 4D reconstructed volumes is highly affected by the …

    vcu Repository record for IMAGE-BASED RESPIRATORY MOTION EXTRACTION AND RESPIRATION-CORRELATED CONE BEAM CT (4D-CBCT) RECONSTRUCTION (opens in a new tab)

  2. Motion Estimation and Motion-Compensated Reconstruction for Four-Dimensional Cone Beam Computed Tomography (4D-CBCT)

    … localization uncertainty and four dimensional (4D) cone beam computed tomography (CBCT) has been developed to locate tumor in each respiration phase to better estimate the possible motion range of the tumor motion during the treatment. However, 4D-CBCT reconstructed by conventional methods on …

    utswmed Repository record for Motion Estimation and Motion-Compensated Reconstruction for Four-Dimensional Cone Beam Computed Tomography (4D-CBCT) (opens in a new tab)

  3. On-Board Imaging of Respiratory Motion: Investigation of Markerless and Self-Sorted Four-Dimensional Cone-Beam CT (4D-CBCT)

    … such as fluoroscopy and 3D cone-beam CT (3D-CBCT). Due to the limited information from these images, larger volumes of healthy tissue are often irradiated in order to ensure the radiation field encompasses the entirety of the target motion. Since the overarching goal of radiation therapy is …

    duke Repository record for On-Board Imaging of Respiratory Motion: Investigation of Markerless and Self-Sorted Four-Dimensional Cone-Beam CT (4D-CBCT) (opens in a new tab)

  4. Deep Learning-Based Motion Compensation for Four-Dimensional Cone-Beam Computed Tomography Reconstruction in Radiation Therapy

    … normal tissues. Cone-beam computed tomography (CBCT) plays an essential role in ensuring the treatment precision by providing on-board volumetric images of the patient’s anatomy, facilitating target localization and patient positioning correction prior to treatment sessions. However, …

    wustl Repository record for Deep Learning-Based Motion Compensation for Four-Dimensional Cone-Beam Computed Tomography Reconstruction in Radiation Therapy (opens in a new tab)

  5. Design and Optimization of Four-Dimensional Cone-Beam Computed to mography In Image-Guided Radiation Therapy

    … four-dimensional cone-beam computed tomography (4D-CBCT), which acquires an image set of the dynamic target throughout the respiratory cycle during the therapy session. 4D-CBCT is undersampled if the scan time is too short. However, short scan time is desirable in clinical practice to reduce …

    uthsc Repository record for Design and Optimization of Four-Dimensional Cone-Beam Computed to mography In Image-Guided Radiation Therapy (opens in a new tab)

  6. Four-Dimensional Imaging of Respiratory Motion in the Radiotherapy Treatment Room Using a Gantry Mounted Flat Panel Imaging Device

    … Four-dimensional cone-beam computed tomography (4D CBCT) using a gantry mounted 2D flat panel imaging device has been proposed but has been limited by high doses, long scan times and severe under-sampling artifacts. The focus of the work completed in this thesis was to find ways to improve 4D …

    duke Repository record for Four-Dimensional Imaging of Respiratory Motion in the Radiotherapy Treatment Room Using a Gantry Mounted Flat Panel Imaging Device (opens in a new tab)

  7. Motion-Induced Artifact Mitigation and Image Enhancement Strategies for Four-Dimensional Fan-Beam and Cone-Beam Computed Tomography

    … cell lung cancer. In radiotherapy applications 4D fan-beam computed tomography (4D-CT) and 4D cone-beam computed tomography (4D-CBCT) are two advanced imaging modalities that afford clinical practitioners knowledge of the underlying kinematics and structural dynamics of diseased tissues and …

    vcu Repository record for Motion-Induced Artifact Mitigation and Image Enhancement Strategies for Four-Dimensional Fan-Beam and Cone-Beam Computed Tomography (opens in a new tab)

  8. Improvements In Four-Dimensional and Dual Energy Computed to mography

    Dual energy and 4D computed tomography (CT) seek to address some of the limitations in traditional CT imaging. Dual energy CT, among other purposes, allows for the quantification and improved visualization of contrast materials, and 4D CT is often used in radiation therapy applications as it allows …

    uthsc Repository record for Improvements In Four-Dimensional and Dual Energy Computed to mography (opens in a new tab)

  9. Optimization of Image Guided Radiation Therapy for Lung Cancer Using Limited-angle Projections

    … as the 3D-DTS technique, but uses the planning 4D computed tomography (CT) to synthesize a phase-matched reference DTS to register with the on-board DTS for tumor localization. Of the 324 different scenarios simulated using the extended cardiac torso (XCAT) digital phantom, the phase-matched DTS …

    duke Repository record for Optimization of Image Guided Radiation Therapy for Lung Cancer Using Limited-angle Projections (opens in a new tab)

  10. CBCT image enhancement for improving accuracy of radiomics analysis and soft tissue target localization

    <p>Cone-beam computed tomography (CBCT) is one of the most commonly used image modalities in radiation therapy. It provides valuable information for target localization and outcome prediction throughout treatment courses. However, CBCT images suffer from various artifacts caused by scattering, beam …

    duke Repository record for CBCT image enhancement for improving accuracy of radiomics analysis and soft tissue target localization (opens in a new tab)

  11. Implementation of respiratory-correlated cone-beam CT on Varian linac systems

    Respiratory-correlated (4D) X-ray CT scans produce a set of images corresponding to different phases of a patient's breathing cycle. In external beam radiotherapy, information about a tumor's motion due to respiration can be used to optimize a treatment plan, provided the patient can be accurately …

    ubc Repository record for Implementation of respiratory-correlated cone-beam CT on Varian linac systems (opens in a new tab) Download PDF for Implementation of respiratory-correlated cone-beam CT on Varian linac systems (opens in a new tab)

  12. Markerless Lung Tumor Trajectory Estimation from Rotating Cone Beam Computed Tomography Projections

    … on free breathing cone beam computed tomography (CBCT) projections, which are 2 dimensional (2D) sequential images rotating about an axis and are used to reconstruct 3D CBCT images. A gold standard tumor trajectory is required to guide the algorithm development and estimate the tumor detection …

    vcu Repository record for Markerless Lung Tumor Trajectory Estimation from Rotating Cone Beam Computed Tomography Projections (opens in a new tab)

  13. Respiratory Prediction and Image Quality Improvement of 4D Cone Beam CT and MRI for Lung Tumor Treatments

    … of imaging techniques such as four-dimensional (4D) Cone Beam Computed Tomography (CBCT) and 4D Magnetic Resonance Imaging (MRI). Specifically, 4D CBCT used in CBCT IGRT requires precise respiratory signal extraction to avoid burry edges, inaccurate tumor shape, and motion-induced artifacts on …

    vcu Repository record for Respiratory Prediction and Image Quality Improvement of 4D Cone Beam CT and MRI for Lung Tumor Treatments (opens in a new tab)

  14. Deep Learning-based Onboard Image Guidance and Dose Verification for Radiation Therapy

    … four-dimensional cone-beam computed tomography (4D-CBCT) is a valuable tool to provide onboard respiration-resolved images for moving targets, but its image quality is degraded by the intra-phase sparse sampling due to the clinical constraints on acquisition time and imaging dose. …

    duke Repository record for Deep Learning-based Onboard Image Guidance and Dose Verification for Radiation Therapy (opens in a new tab)

  15. Investigation of Imaging Capabilities for Dual Cone-Beam Computed Tomography

    … bench-top dual cone-beam computed tomography (CBCT) system was developed consisting of two orthogonally placed 40x30 cm<super>2</super> flat-panel detectors and two conventional X-ray tubes with two individual high-voltage generators sharing the same rotational axis. The X-ray source to …

    duke Repository record for Investigation of Imaging Capabilities for Dual Cone-Beam Computed Tomography (opens in a new tab)

  16. On-board Image Augmentation Using Prior Image and Deep Learning for Image-guided Radiation Therapy

    <p>Cone-beam Computed Tomography (CBCT) has been widely used in image-guided radiation therapy for target localization. 3D CBCT has been developed for localizing static targets, while 4D CBCT has been developed for localizing moving targets. Although CBCT has been used as the gold standard in …

    duke Repository record for On-board Image Augmentation Using Prior Image and Deep Learning for Image-guided Radiation Therapy (opens in a new tab)

  17. Volumetric Cine Imaging for On-board Target Localization in Radiation Therapy

    … respiratory motions. On-board four-dimensional (4D) or real-time verification of the tumor before and during Stereotactic Body Radiation Therapy (SBRT) is necessary because SBRT uses high fractional doses, tight Planning Target Volume (PTV) margins and a long treatment time. Current imaging of …

    duke Repository record for Volumetric Cine Imaging for On-board Target Localization in Radiation Therapy (opens in a new tab)